Are the 4-channel SNAP digital input cards interchangeable? Forum - Published: Good morning, We’ve been using the standard SNAP-IDC5 input card to “count” pulse signals from a water flow paddlewheel sensor to calculate the flow (at fairly high speed, e.g. 93 pulses = 1 Liter). I...moreGood morning, We’ve been using the standard SNAP-IDC5 input card to “count” pulse signals from a water flow paddlewheel sensor to calculate the flow (at fairly high speed, e.g. 93 pulses = 1 Liter). I just noticed there is a similar SNAP-IDC5-FAST-A card that seems might be more suited for the application. Without changing our PAC strategy (would require version update), would the strategy still correctly detect and calculate the water flow? (I’m hoping our same software version would still wo...... <less Display CODESYS string variable in Groov View Forum - Published: I have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I...moreI have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I click on the other variables (INT16s, Booleans, Floats), I see a list of available gadgets that I can drag into the preview space. However, when I click on foo, I don’t get any options. I’ve also tried creating a Text Area gadget from the Gadgets menu, but when I select my tag in the Data Source m...... <less Node-Red: Dynamic Groov I/O Module & Channel Index Forum - Published: Is it possible to dynamically set the values of the module/channel index fields for the Groov I/O nodes? Fairly sure I know the answer is no. But want to ask just in case I’m missing something. I am...moreIs it possible to dynamically set the values of the module/channel index fields for the Groov I/O nodes? Fairly sure I know the answer is no. But want to ask just in case I’m missing something. I am trying to handle incoming HTTP requests that have an asphalt silo number in the payload. It would be great to dynamically set the module/channel index based on the payload so I could have 1 flow to trigger N number of silos instead of needing to configure 1 flow per silo.... <less Trigger Command for Node-RED save to file time period Forum - Published: Hi, I’ve built a data logger that grabs certain points every minute from my Epic and writes the values to a csv file. I use the injector to run this. However, I’m looking for the following to make this...moreHi, I’ve built a data logger that grabs certain points every minute from my Epic and writes the values to a csv file. I use the injector to run this. However, I’m looking for the following to make this enhanced: only pulls the data starting at 8am and stops pulling the data at 4pm. each day it creates a new file log called APM1_Temp_Log_[new date].csv The new file will go to the same path /home/dev/secured/… but will be rename each day to the new date. Right now I’m using the edit-write-edit-n...... <less Problem with Groov View Forum - Published: Hello I have a system running with EPIC PR1(3.4.4) (PacControl, Node-Red, GroovView and MariaDB), it has worked well for a few weeks but lately the GroovView HMI freezes (I have no trends and there is...moreHello I have a system running with EPIC PR1(3.4.4) (PacControl, Node-Red, GroovView and MariaDB), it has worked well for a few weeks but lately the GroovView HMI freezes (I have no trends and there is little data that I show, around of 35 variables) and the controller stops working (Pac Control and Node-Red). To get everything working again I had to restart GroovView (using Groov Manage). I have checked the logs and there is nothing. I have noticed that the CPU temperature is 70 degrees and the ...... <less C++ OptoMMP SDK function for getting/setting engineering units? Forum - Published: Hello, I was wondering if there was a function/method that was part of the C++ OptoMMP SDK that would allow you to either set and/or get the engineering units for a given channel. Basically looking on...moreHello, I was wondering if there was a function/method that was part of the C++ OptoMMP SDK that would allow you to either set and/or get the engineering units for a given channel. Basically looking on how to programmatically get the Unit value from below: image913×1207 54.8 KB The closet functions I could find seemed to be GetPointConfigurationEx4() or SetPointConfigurationEx4(). However the struct passed to this (SIOMM_PointConfigArea4) doesn’t have a Unit member. Tried searching the documentat...... <less Adding a timestamp to data sent to csv file Forum - Published: I’ve created a data logger pulling analog points from my Opto Epic using the following in Node-RED: inject (msg.payload = timestamp) > groov i/o read node > change node (msg.payload to the value of...moreI’ve created a data logger pulling analog points from my Opto Epic using the following in Node-RED: inject (msg.payload = timestamp) > groov i/o read node > change node (msg.payload to the value of “value_name,” & msg.payload) > write file node (path with a file .csv) Right now I get the proper analog value coming in to the csv file as expected but there’s no timestamp allocated to each interval. I suspect I need to add something in the change node but what?? Thanks, Spencer... <less Snap-Pac-R1 and LabVIEW interface Forum - Published: Hey everyone. I am trying to integrate OPTO22 into a previous LabVIEW vi. Does anyone have some examples or previously written LabVIEW vi’s that I can tweak to interface with my current project? I will...moreHey everyone. I am trying to integrate OPTO22 into a previous LabVIEW vi. Does anyone have some examples or previously written LabVIEW vi’s that I can tweak to interface with my current project? I will need to connect over ethernet and cannot use SNMP. It will need to be another communication format. Any help would be greatly appreciate as I am new to both LabVIEW and OPTO22 interface. Kevin... <less Opto Epic I/O points collected in a data-logger to csv file Forum - Published: I’m trying to build a simple data logger collecting I/O points (mostly just analog values), from the Opto Epic (we have PAC Controller also. Basically need a timestamp, roughly 10 analog points collected...moreI’m trying to build a simple data logger collecting I/O points (mostly just analog values), from the Opto Epic (we have PAC Controller also. Basically need a timestamp, roughly 10 analog points collected every 5 seconds, put into one CSV file (each day would be a new file name based on date: 2024-01-23) and within the csv file it would have a column for the timestamp, value 1, value 2, value 3…etc. Much appreciated.... <less Deleting Unused Images In Groov View Forum - Published: Hey Folks. So, I have been creating and adding images to my Groov View project. Its looking good! However, I now have some images I’m not using. I’d like to find the folder these images I import in are...moreHey Folks. So, I have been creating and adding images to my Groov View project. Its looking good! However, I now have some images I’m not using. I’d like to find the folder these images I import in are stored and delete them. Any idea where this folder would be? Thank you.... <less How to use the GRV-IDCIS-12 to measure RPMS Forum - Published: Hello. I am having difficulties trying to program this module to measure RPMS. I am using a proximity sensor that is being toggled by a metal screw on a plastic rotating shaft. This module doesn’t have...moreHello. I am having difficulties trying to program this module to measure RPMS. I am using a proximity sensor that is being toggled by a metal screw on a plastic rotating shaft. This module doesn’t have the features to set so I am trying to get around that for the time being. I am trying to have the screw start a count-up timer that keeps restarting when it sees it again. I want to input that value from the count-up timer into a formula to output value. I am not much of a programmer at all so any...... <less Groov View Drawings and Things Forum - Published: Good afternoon. I’m still using the Trial Version of Groov View. I’m trying to build an Overview of our Facilities to illustrate machine state and data. I’m wondering if there is more drawing tools in...moreGood afternoon. I’m still using the Trial Version of Groov View. I’m trying to build an Overview of our Facilities to illustrate machine state and data. I’m wondering if there is more drawing tools in the full version of Groov View. I find I’m very limited in drawing simple objects. I can import images, but I don’t have an option to draw for example a line or a line that is on a diagonal. I don’t really see an option to draw anything. I can place a Rectangle or an Oval. That is about it. I’m gue...... <less goovView Trends Float variable too long Forum - Published: I took the EPIC class last year, August class, I asked how to truncate float variables in groovView trend graphs. Terry said he had a solution in your forums. I couldn’t find it. Please give me...moreI took the EPIC class last year, August class, I asked how to truncate float variables in groovView trend graphs. Terry said he had a solution in your forums. I couldn’t find it. Please give me directions to shorten the decimal places on float variables when using a trend in groovView. 15 decimal places is too much, not just for groovView trends, but also when I send an event as a text it makes it difficult to see on the phone screen. I’m using EPIC PR1 with Firmware 3.5 and PAC Project 10.5b ru...... <less Printer Interface via an EPIC Controller Forum - Published: Have an existing system using an EPIC controller (PACProject) with Groov View via the HDMI port that needs to print reports. The intent is to try to do this without adding a PC to the system. I’ve done...moreHave an existing system using an EPIC controller (PACProject) with Groov View via the HDMI port that needs to print reports. The intent is to try to do this without adding a PC to the system. I’ve done ASCII to Serial (RS232) Printers years ago (via PACProject and an PAC-R) BUT serial printers are not as common today (most are for labels or receipts). Is there a way (or has anybody already done this) via Node-Red, PACControl, shell access, etc. that we can send our Text Files to a standard Ether...... <less Question On Trending in Groov View Forum - Published: Good morning. My situation is… I’m using the trial version of Groov View Server for Windows on a PC currently. I have a lot of trends that are all working nicely reading PLC tags from various sources...moreGood morning. My situation is… I’m using the trial version of Groov View Server for Windows on a PC currently. I have a lot of trends that are all working nicely reading PLC tags from various sources (Coming from Node-Red EthernetIP Nodes). Currently I have to re-start the Groov Server and reopen Groov View every two hours as it’s a trial version. If I restart the server immediately upon timing out, then I retain my older data. If it sits for a bit before reopening, I lose my older data. My ques...... <less Sensors that can tap into (so we can monitor and/or manipulate) badge access to one of our more sophisticated machine shop devices, like a laser cutter Forum - Published: We’re starting our Industry 4.0 transformation with the groov RIO (& eventually EPIC) product line. We’re looking for sensors that can tap into (so we can monitor and/or manipulate) badge access to one...moreWe’re starting our Industry 4.0 transformation with the groov RIO (& eventually EPIC) product line. We’re looking for sensors that can tap into (so we can monitor and/or manipulate) badge access to one of our more sophisticated machine shop devices, like a laser cutter. We went to ensure that the technician is qualified to operate the equipment. Any thoughts or suggestions?... <less RIO Device Scan unavailable? Forum - Published: Hello everyone, Trying to play with getting this RIO (MM1001-10) going with Codesys. I have successfully connected to it and gone online, however I cannot seem to scan the device for its I/O? Do I...moreHello everyone, Trying to play with getting this RIO (MM1001-10) going with Codesys. I have successfully connected to it and gone online, however I cannot seem to scan the device for its I/O? Do I need to set up each I/O channel in Groov manage first or am I missing something? Thanks in advance!... <less Read/Write I/O using commands to read/write enter I/O unit all at once Forum - Published: This is mainly a question about OptoControl, but as we move our hardware to groov, we are looking at ways to streamline our process. We’ve recently had a lot of issues (I/O units becoming disabled and...moreThis is mainly a question about OptoControl, but as we move our hardware to groov, we are looking at ways to streamline our process. We’ve recently had a lot of issues (I/O units becoming disabled and taking to long to be able to get them communicating again is the primary issue) communicating over serial cables on our LCM4 controllers so we’ve changed how we read/write to the I/O using the the following commands: MoveMixedIoUnitToTable MoveTableToMixedIoUnit MoveAnalogIoUnitToTable MoveTableToA...... <less Node-red energy meter rs485 modbus connection Forum - Published: Hello there, i have some problems with node-re modbus connection via rs485. i have conencted raspberry to Yada dcm6636 energy meter via rs485 port. The port open and communicate each other but in node...moreHello there, i have some problems with node-re modbus connection via rs485. i have conencted raspberry to Yada dcm6636 energy meter via rs485 port. The port open and communicate each other but in node-red no values come and it give time out error. is there know this problem’s solution anyone... <less Updating node-red project API Forum - Published: Hello! I’m working on setting up a CI pipeline for our node-red project and and I would like to automate the deployment to target. I thought maybe I could use the node-red admin API. More specifically...moreHello! I’m working on setting up a CI pipeline for our node-red project and and I would like to automate the deployment to target. I thought maybe I could use the node-red admin API. More specifically the POST /flows. However, when I try to use the API all I get is this: 301 Moved Permanently 301 Moved Permanently nginx/1.20.1 Is the node-red admin API not available on the groov EPIC? Are th...... <less I want to 32 crc and 30 crc and 16 crc with my own polynomial Forum - Published: I want to 32 crc and 30 crc and 16 crc with my own polynomial ,how can I implement this using opto scripting? please reply...I want to 32 crc and 30 crc and 16 crc with my own polynomial ,how can I implement this using opto scripting? please reply... <less EtherNet/IP Configurator for Groov? Forum - Published: I’ve been experimenting this week with the EtherNet/IP Configurator for SNAP PAC hardware. Is it possible to configure similar communication for I/O attached directly to a Groov EPIC-PR1?...I’ve been experimenting this week with the EtherNet/IP Configurator for SNAP PAC hardware. Is it possible to configure similar communication for I/O attached directly to a Groov EPIC-PR1?... <less Understanding high-density channel data for streaming via UDP Forum - Published: Hello, I am trying to understand how to interrupt the high-density channel data located in the OPTOMMP starting at address FFFF F100 0300. According to the structure on page 155 of the manual, this...moreHello, I am trying to understand how to interrupt the high-density channel data located in the OPTOMMP starting at address FFFF F100 0300. According to the structure on page 155 of the manual, this section should have the analog channels value in engineering units and the feature data for digital channels. image898×508 86.9 KB For now, I am trying to read the state of a digital output from a GRV-ODCI-12 card located in slot 0. The controller is a GRV-EPIC-PR1. From looking at the Generic MMP usi...... <less A problem in TCP/IP communication Forum - Published: A R1 controller and 10 temperature and humidity modules communicate through Ethernet. The control strategy in R1 uses an Ethernet communication handle to connect different temperature and humidity...moreA R1 controller and 10 temperature and humidity modules communicate through Ethernet. The control strategy in R1 uses an Ethernet communication handle to connect different temperature and humidity meters by changing the parameters of the communication handle. The R1 controller is the client of TCP communication. To test the effectiveness of TCP communication, I set the polling interval to 100ms, so there is no need for such fast polling during normal use. R1 has been running normally for several...... <less Issue in Opto 22 Groov EPIC PR2 Forum - Published: We are facing critical issues in our current setup involving OPTO 22 GROOV EPIC PR2 PLC and the Ignition Full V8.17 system. Our system configuration includes- OPTO 22 PLC: First Ethernet port- Serum...moreWe are facing critical issues in our current setup involving OPTO 22 GROOV EPIC PR2 PLC and the Ignition Full V8.17 system. Our system configuration includes- OPTO 22 PLC: First Ethernet port- Serum Corporate IP & Second Ethernet port- Local IP of Siemens PLC network. Implemented Data store-and-forward within the OPTO 22 PLC. Established communication between Ignition and 6 nos of Siemens PLCs using OPC devices within the OPTO 22. Integration of 6 databases communication with SQL 2019 in...... <less « PreviousPage 4 of 128Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Display CODESYS string variable in Groov View Forum - Published: I have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I...moreI have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I click on the other variables (INT16s, Booleans, Floats), I see a list of available gadgets that I can drag into the preview space. However, when I click on foo, I don’t get any options. I’ve also tried creating a Text Area gadget from the Gadgets menu, but when I select my tag in the Data Source m...... <less Node-Red: Dynamic Groov I/O Module & Channel Index Forum - Published: Is it possible to dynamically set the values of the module/channel index fields for the Groov I/O nodes? Fairly sure I know the answer is no. But want to ask just in case I’m missing something. I am...moreIs it possible to dynamically set the values of the module/channel index fields for the Groov I/O nodes? Fairly sure I know the answer is no. But want to ask just in case I’m missing something. I am trying to handle incoming HTTP requests that have an asphalt silo number in the payload. It would be great to dynamically set the module/channel index based on the payload so I could have 1 flow to trigger N number of silos instead of needing to configure 1 flow per silo.... <less Trigger Command for Node-RED save to file time period Forum - Published: Hi, I’ve built a data logger that grabs certain points every minute from my Epic and writes the values to a csv file. I use the injector to run this. However, I’m looking for the following to make this...moreHi, I’ve built a data logger that grabs certain points every minute from my Epic and writes the values to a csv file. I use the injector to run this. However, I’m looking for the following to make this enhanced: only pulls the data starting at 8am and stops pulling the data at 4pm. each day it creates a new file log called APM1_Temp_Log_[new date].csv The new file will go to the same path /home/dev/secured/… but will be rename each day to the new date. Right now I’m using the edit-write-edit-n...... <less Problem with Groov View Forum - Published: Hello I have a system running with EPIC PR1(3.4.4) (PacControl, Node-Red, GroovView and MariaDB), it has worked well for a few weeks but lately the GroovView HMI freezes (I have no trends and there is...moreHello I have a system running with EPIC PR1(3.4.4) (PacControl, Node-Red, GroovView and MariaDB), it has worked well for a few weeks but lately the GroovView HMI freezes (I have no trends and there is little data that I show, around of 35 variables) and the controller stops working (Pac Control and Node-Red). To get everything working again I had to restart GroovView (using Groov Manage). I have checked the logs and there is nothing. I have noticed that the CPU temperature is 70 degrees and the ...... <less C++ OptoMMP SDK function for getting/setting engineering units? Forum - Published: Hello, I was wondering if there was a function/method that was part of the C++ OptoMMP SDK that would allow you to either set and/or get the engineering units for a given channel. Basically looking on...moreHello, I was wondering if there was a function/method that was part of the C++ OptoMMP SDK that would allow you to either set and/or get the engineering units for a given channel. Basically looking on how to programmatically get the Unit value from below: image913×1207 54.8 KB The closet functions I could find seemed to be GetPointConfigurationEx4() or SetPointConfigurationEx4(). However the struct passed to this (SIOMM_PointConfigArea4) doesn’t have a Unit member. Tried searching the documentat...... <less Adding a timestamp to data sent to csv file Forum - Published: I’ve created a data logger pulling analog points from my Opto Epic using the following in Node-RED: inject (msg.payload = timestamp) > groov i/o read node > change node (msg.payload to the value of...moreI’ve created a data logger pulling analog points from my Opto Epic using the following in Node-RED: inject (msg.payload = timestamp) > groov i/o read node > change node (msg.payload to the value of “value_name,” & msg.payload) > write file node (path with a file .csv) Right now I get the proper analog value coming in to the csv file as expected but there’s no timestamp allocated to each interval. I suspect I need to add something in the change node but what?? Thanks, Spencer... <less Snap-Pac-R1 and LabVIEW interface Forum - Published: Hey everyone. I am trying to integrate OPTO22 into a previous LabVIEW vi. Does anyone have some examples or previously written LabVIEW vi’s that I can tweak to interface with my current project? I will...moreHey everyone. I am trying to integrate OPTO22 into a previous LabVIEW vi. Does anyone have some examples or previously written LabVIEW vi’s that I can tweak to interface with my current project? I will need to connect over ethernet and cannot use SNMP. It will need to be another communication format. Any help would be greatly appreciate as I am new to both LabVIEW and OPTO22 interface. Kevin... <less Opto Epic I/O points collected in a data-logger to csv file Forum - Published: I’m trying to build a simple data logger collecting I/O points (mostly just analog values), from the Opto Epic (we have PAC Controller also. Basically need a timestamp, roughly 10 analog points collected...moreI’m trying to build a simple data logger collecting I/O points (mostly just analog values), from the Opto Epic (we have PAC Controller also. Basically need a timestamp, roughly 10 analog points collected every 5 seconds, put into one CSV file (each day would be a new file name based on date: 2024-01-23) and within the csv file it would have a column for the timestamp, value 1, value 2, value 3…etc. Much appreciated.... <less Deleting Unused Images In Groov View Forum - Published: Hey Folks. So, I have been creating and adding images to my Groov View project. Its looking good! However, I now have some images I’m not using. I’d like to find the folder these images I import in are...moreHey Folks. So, I have been creating and adding images to my Groov View project. Its looking good! However, I now have some images I’m not using. I’d like to find the folder these images I import in are stored and delete them. Any idea where this folder would be? Thank you.... <less How to use the GRV-IDCIS-12 to measure RPMS Forum - Published: Hello. I am having difficulties trying to program this module to measure RPMS. I am using a proximity sensor that is being toggled by a metal screw on a plastic rotating shaft. This module doesn’t have...moreHello. I am having difficulties trying to program this module to measure RPMS. I am using a proximity sensor that is being toggled by a metal screw on a plastic rotating shaft. This module doesn’t have the features to set so I am trying to get around that for the time being. I am trying to have the screw start a count-up timer that keeps restarting when it sees it again. I want to input that value from the count-up timer into a formula to output value. I am not much of a programmer at all so any...... <less Groov View Drawings and Things Forum - Published: Good afternoon. I’m still using the Trial Version of Groov View. I’m trying to build an Overview of our Facilities to illustrate machine state and data. I’m wondering if there is more drawing tools in...moreGood afternoon. I’m still using the Trial Version of Groov View. I’m trying to build an Overview of our Facilities to illustrate machine state and data. I’m wondering if there is more drawing tools in the full version of Groov View. I find I’m very limited in drawing simple objects. I can import images, but I don’t have an option to draw for example a line or a line that is on a diagonal. I don’t really see an option to draw anything. I can place a Rectangle or an Oval. That is about it. I’m gue...... <less goovView Trends Float variable too long Forum - Published: I took the EPIC class last year, August class, I asked how to truncate float variables in groovView trend graphs. Terry said he had a solution in your forums. I couldn’t find it. Please give me...moreI took the EPIC class last year, August class, I asked how to truncate float variables in groovView trend graphs. Terry said he had a solution in your forums. I couldn’t find it. Please give me directions to shorten the decimal places on float variables when using a trend in groovView. 15 decimal places is too much, not just for groovView trends, but also when I send an event as a text it makes it difficult to see on the phone screen. I’m using EPIC PR1 with Firmware 3.5 and PAC Project 10.5b ru...... <less Printer Interface via an EPIC Controller Forum - Published: Have an existing system using an EPIC controller (PACProject) with Groov View via the HDMI port that needs to print reports. The intent is to try to do this without adding a PC to the system. I’ve done...moreHave an existing system using an EPIC controller (PACProject) with Groov View via the HDMI port that needs to print reports. The intent is to try to do this without adding a PC to the system. I’ve done ASCII to Serial (RS232) Printers years ago (via PACProject and an PAC-R) BUT serial printers are not as common today (most are for labels or receipts). Is there a way (or has anybody already done this) via Node-Red, PACControl, shell access, etc. that we can send our Text Files to a standard Ether...... <less Question On Trending in Groov View Forum - Published: Good morning. My situation is… I’m using the trial version of Groov View Server for Windows on a PC currently. I have a lot of trends that are all working nicely reading PLC tags from various sources...moreGood morning. My situation is… I’m using the trial version of Groov View Server for Windows on a PC currently. I have a lot of trends that are all working nicely reading PLC tags from various sources (Coming from Node-Red EthernetIP Nodes). Currently I have to re-start the Groov Server and reopen Groov View every two hours as it’s a trial version. If I restart the server immediately upon timing out, then I retain my older data. If it sits for a bit before reopening, I lose my older data. My ques...... <less Sensors that can tap into (so we can monitor and/or manipulate) badge access to one of our more sophisticated machine shop devices, like a laser cutter Forum - Published: We’re starting our Industry 4.0 transformation with the groov RIO (& eventually EPIC) product line. We’re looking for sensors that can tap into (so we can monitor and/or manipulate) badge access to one...moreWe’re starting our Industry 4.0 transformation with the groov RIO (& eventually EPIC) product line. We’re looking for sensors that can tap into (so we can monitor and/or manipulate) badge access to one of our more sophisticated machine shop devices, like a laser cutter. We went to ensure that the technician is qualified to operate the equipment. Any thoughts or suggestions?... <less RIO Device Scan unavailable? Forum - Published: Hello everyone, Trying to play with getting this RIO (MM1001-10) going with Codesys. I have successfully connected to it and gone online, however I cannot seem to scan the device for its I/O? Do I...moreHello everyone, Trying to play with getting this RIO (MM1001-10) going with Codesys. I have successfully connected to it and gone online, however I cannot seem to scan the device for its I/O? Do I need to set up each I/O channel in Groov manage first or am I missing something? Thanks in advance!... <less Read/Write I/O using commands to read/write enter I/O unit all at once Forum - Published: This is mainly a question about OptoControl, but as we move our hardware to groov, we are looking at ways to streamline our process. We’ve recently had a lot of issues (I/O units becoming disabled and...moreThis is mainly a question about OptoControl, but as we move our hardware to groov, we are looking at ways to streamline our process. We’ve recently had a lot of issues (I/O units becoming disabled and taking to long to be able to get them communicating again is the primary issue) communicating over serial cables on our LCM4 controllers so we’ve changed how we read/write to the I/O using the the following commands: MoveMixedIoUnitToTable MoveTableToMixedIoUnit MoveAnalogIoUnitToTable MoveTableToA...... <less Node-red energy meter rs485 modbus connection Forum - Published: Hello there, i have some problems with node-re modbus connection via rs485. i have conencted raspberry to Yada dcm6636 energy meter via rs485 port. The port open and communicate each other but in node...moreHello there, i have some problems with node-re modbus connection via rs485. i have conencted raspberry to Yada dcm6636 energy meter via rs485 port. The port open and communicate each other but in node-red no values come and it give time out error. is there know this problem’s solution anyone... <less Updating node-red project API Forum - Published: Hello! I’m working on setting up a CI pipeline for our node-red project and and I would like to automate the deployment to target. I thought maybe I could use the node-red admin API. More specifically...moreHello! I’m working on setting up a CI pipeline for our node-red project and and I would like to automate the deployment to target. I thought maybe I could use the node-red admin API. More specifically the POST /flows. However, when I try to use the API all I get is this: 301 Moved Permanently 301 Moved Permanently nginx/1.20.1 Is the node-red admin API not available on the groov EPIC? Are th...... <less I want to 32 crc and 30 crc and 16 crc with my own polynomial Forum - Published: I want to 32 crc and 30 crc and 16 crc with my own polynomial ,how can I implement this using opto scripting? please reply...I want to 32 crc and 30 crc and 16 crc with my own polynomial ,how can I implement this using opto scripting? please reply... <less EtherNet/IP Configurator for Groov? Forum - Published: I’ve been experimenting this week with the EtherNet/IP Configurator for SNAP PAC hardware. Is it possible to configure similar communication for I/O attached directly to a Groov EPIC-PR1?...I’ve been experimenting this week with the EtherNet/IP Configurator for SNAP PAC hardware. Is it possible to configure similar communication for I/O attached directly to a Groov EPIC-PR1?... <less Understanding high-density channel data for streaming via UDP Forum - Published: Hello, I am trying to understand how to interrupt the high-density channel data located in the OPTOMMP starting at address FFFF F100 0300. According to the structure on page 155 of the manual, this...moreHello, I am trying to understand how to interrupt the high-density channel data located in the OPTOMMP starting at address FFFF F100 0300. According to the structure on page 155 of the manual, this section should have the analog channels value in engineering units and the feature data for digital channels. image898×508 86.9 KB For now, I am trying to read the state of a digital output from a GRV-ODCI-12 card located in slot 0. The controller is a GRV-EPIC-PR1. From looking at the Generic MMP usi...... <less A problem in TCP/IP communication Forum - Published: A R1 controller and 10 temperature and humidity modules communicate through Ethernet. The control strategy in R1 uses an Ethernet communication handle to connect different temperature and humidity...moreA R1 controller and 10 temperature and humidity modules communicate through Ethernet. The control strategy in R1 uses an Ethernet communication handle to connect different temperature and humidity meters by changing the parameters of the communication handle. The R1 controller is the client of TCP communication. To test the effectiveness of TCP communication, I set the polling interval to 100ms, so there is no need for such fast polling during normal use. R1 has been running normally for several...... <less Issue in Opto 22 Groov EPIC PR2 Forum - Published: We are facing critical issues in our current setup involving OPTO 22 GROOV EPIC PR2 PLC and the Ignition Full V8.17 system. Our system configuration includes- OPTO 22 PLC: First Ethernet port- Serum...moreWe are facing critical issues in our current setup involving OPTO 22 GROOV EPIC PR2 PLC and the Ignition Full V8.17 system. Our system configuration includes- OPTO 22 PLC: First Ethernet port- Serum Corporate IP & Second Ethernet port- Local IP of Siemens PLC network. Implemented Data store-and-forward within the OPTO 22 PLC. Established communication between Ignition and 6 nos of Siemens PLCs using OPC devices within the OPTO 22. Integration of 6 databases communication with SQL 2019 in...... <less « PreviousPage 4 of 128Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Node-Red: Dynamic Groov I/O Module & Channel Index Forum - Published: Is it possible to dynamically set the values of the module/channel index fields for the Groov I/O nodes? Fairly sure I know the answer is no. But want to ask just in case I’m missing something. I am...moreIs it possible to dynamically set the values of the module/channel index fields for the Groov I/O nodes? Fairly sure I know the answer is no. But want to ask just in case I’m missing something. I am trying to handle incoming HTTP requests that have an asphalt silo number in the payload. It would be great to dynamically set the module/channel index based on the payload so I could have 1 flow to trigger N number of silos instead of needing to configure 1 flow per silo.... <less Trigger Command for Node-RED save to file time period Forum - Published: Hi, I’ve built a data logger that grabs certain points every minute from my Epic and writes the values to a csv file. I use the injector to run this. However, I’m looking for the following to make this...moreHi, I’ve built a data logger that grabs certain points every minute from my Epic and writes the values to a csv file. I use the injector to run this. However, I’m looking for the following to make this enhanced: only pulls the data starting at 8am and stops pulling the data at 4pm. each day it creates a new file log called APM1_Temp_Log_[new date].csv The new file will go to the same path /home/dev/secured/… but will be rename each day to the new date. Right now I’m using the edit-write-edit-n...... <less Problem with Groov View Forum - Published: Hello I have a system running with EPIC PR1(3.4.4) (PacControl, Node-Red, GroovView and MariaDB), it has worked well for a few weeks but lately the GroovView HMI freezes (I have no trends and there is...moreHello I have a system running with EPIC PR1(3.4.4) (PacControl, Node-Red, GroovView and MariaDB), it has worked well for a few weeks but lately the GroovView HMI freezes (I have no trends and there is little data that I show, around of 35 variables) and the controller stops working (Pac Control and Node-Red). To get everything working again I had to restart GroovView (using Groov Manage). I have checked the logs and there is nothing. I have noticed that the CPU temperature is 70 degrees and the ...... <less C++ OptoMMP SDK function for getting/setting engineering units? Forum - Published: Hello, I was wondering if there was a function/method that was part of the C++ OptoMMP SDK that would allow you to either set and/or get the engineering units for a given channel. Basically looking on...moreHello, I was wondering if there was a function/method that was part of the C++ OptoMMP SDK that would allow you to either set and/or get the engineering units for a given channel. Basically looking on how to programmatically get the Unit value from below: image913×1207 54.8 KB The closet functions I could find seemed to be GetPointConfigurationEx4() or SetPointConfigurationEx4(). However the struct passed to this (SIOMM_PointConfigArea4) doesn’t have a Unit member. Tried searching the documentat...... <less Adding a timestamp to data sent to csv file Forum - Published: I’ve created a data logger pulling analog points from my Opto Epic using the following in Node-RED: inject (msg.payload = timestamp) > groov i/o read node > change node (msg.payload to the value of...moreI’ve created a data logger pulling analog points from my Opto Epic using the following in Node-RED: inject (msg.payload = timestamp) > groov i/o read node > change node (msg.payload to the value of “value_name,” & msg.payload) > write file node (path with a file .csv) Right now I get the proper analog value coming in to the csv file as expected but there’s no timestamp allocated to each interval. I suspect I need to add something in the change node but what?? Thanks, Spencer... <less Snap-Pac-R1 and LabVIEW interface Forum - Published: Hey everyone. I am trying to integrate OPTO22 into a previous LabVIEW vi. Does anyone have some examples or previously written LabVIEW vi’s that I can tweak to interface with my current project? I will...moreHey everyone. I am trying to integrate OPTO22 into a previous LabVIEW vi. Does anyone have some examples or previously written LabVIEW vi’s that I can tweak to interface with my current project? I will need to connect over ethernet and cannot use SNMP. It will need to be another communication format. Any help would be greatly appreciate as I am new to both LabVIEW and OPTO22 interface. Kevin... <less Opto Epic I/O points collected in a data-logger to csv file Forum - Published: I’m trying to build a simple data logger collecting I/O points (mostly just analog values), from the Opto Epic (we have PAC Controller also. Basically need a timestamp, roughly 10 analog points collected...moreI’m trying to build a simple data logger collecting I/O points (mostly just analog values), from the Opto Epic (we have PAC Controller also. Basically need a timestamp, roughly 10 analog points collected every 5 seconds, put into one CSV file (each day would be a new file name based on date: 2024-01-23) and within the csv file it would have a column for the timestamp, value 1, value 2, value 3…etc. Much appreciated.... <less Deleting Unused Images In Groov View Forum - Published: Hey Folks. So, I have been creating and adding images to my Groov View project. Its looking good! However, I now have some images I’m not using. I’d like to find the folder these images I import in are...moreHey Folks. So, I have been creating and adding images to my Groov View project. Its looking good! However, I now have some images I’m not using. I’d like to find the folder these images I import in are stored and delete them. Any idea where this folder would be? Thank you.... <less How to use the GRV-IDCIS-12 to measure RPMS Forum - Published: Hello. I am having difficulties trying to program this module to measure RPMS. I am using a proximity sensor that is being toggled by a metal screw on a plastic rotating shaft. This module doesn’t have...moreHello. I am having difficulties trying to program this module to measure RPMS. I am using a proximity sensor that is being toggled by a metal screw on a plastic rotating shaft. This module doesn’t have the features to set so I am trying to get around that for the time being. I am trying to have the screw start a count-up timer that keeps restarting when it sees it again. I want to input that value from the count-up timer into a formula to output value. I am not much of a programmer at all so any...... <less Groov View Drawings and Things Forum - Published: Good afternoon. I’m still using the Trial Version of Groov View. I’m trying to build an Overview of our Facilities to illustrate machine state and data. I’m wondering if there is more drawing tools in...moreGood afternoon. I’m still using the Trial Version of Groov View. I’m trying to build an Overview of our Facilities to illustrate machine state and data. I’m wondering if there is more drawing tools in the full version of Groov View. I find I’m very limited in drawing simple objects. I can import images, but I don’t have an option to draw for example a line or a line that is on a diagonal. I don’t really see an option to draw anything. I can place a Rectangle or an Oval. That is about it. I’m gue...... <less goovView Trends Float variable too long Forum - Published: I took the EPIC class last year, August class, I asked how to truncate float variables in groovView trend graphs. Terry said he had a solution in your forums. I couldn’t find it. Please give me...moreI took the EPIC class last year, August class, I asked how to truncate float variables in groovView trend graphs. Terry said he had a solution in your forums. I couldn’t find it. Please give me directions to shorten the decimal places on float variables when using a trend in groovView. 15 decimal places is too much, not just for groovView trends, but also when I send an event as a text it makes it difficult to see on the phone screen. I’m using EPIC PR1 with Firmware 3.5 and PAC Project 10.5b ru...... <less Printer Interface via an EPIC Controller Forum - Published: Have an existing system using an EPIC controller (PACProject) with Groov View via the HDMI port that needs to print reports. The intent is to try to do this without adding a PC to the system. I’ve done...moreHave an existing system using an EPIC controller (PACProject) with Groov View via the HDMI port that needs to print reports. The intent is to try to do this without adding a PC to the system. I’ve done ASCII to Serial (RS232) Printers years ago (via PACProject and an PAC-R) BUT serial printers are not as common today (most are for labels or receipts). Is there a way (or has anybody already done this) via Node-Red, PACControl, shell access, etc. that we can send our Text Files to a standard Ether...... <less Question On Trending in Groov View Forum - Published: Good morning. My situation is… I’m using the trial version of Groov View Server for Windows on a PC currently. I have a lot of trends that are all working nicely reading PLC tags from various sources...moreGood morning. My situation is… I’m using the trial version of Groov View Server for Windows on a PC currently. I have a lot of trends that are all working nicely reading PLC tags from various sources (Coming from Node-Red EthernetIP Nodes). Currently I have to re-start the Groov Server and reopen Groov View every two hours as it’s a trial version. If I restart the server immediately upon timing out, then I retain my older data. If it sits for a bit before reopening, I lose my older data. My ques...... <less Sensors that can tap into (so we can monitor and/or manipulate) badge access to one of our more sophisticated machine shop devices, like a laser cutter Forum - Published: We’re starting our Industry 4.0 transformation with the groov RIO (& eventually EPIC) product line. We’re looking for sensors that can tap into (so we can monitor and/or manipulate) badge access to one...moreWe’re starting our Industry 4.0 transformation with the groov RIO (& eventually EPIC) product line. We’re looking for sensors that can tap into (so we can monitor and/or manipulate) badge access to one of our more sophisticated machine shop devices, like a laser cutter. We went to ensure that the technician is qualified to operate the equipment. Any thoughts or suggestions?... <less RIO Device Scan unavailable? Forum - Published: Hello everyone, Trying to play with getting this RIO (MM1001-10) going with Codesys. I have successfully connected to it and gone online, however I cannot seem to scan the device for its I/O? Do I...moreHello everyone, Trying to play with getting this RIO (MM1001-10) going with Codesys. I have successfully connected to it and gone online, however I cannot seem to scan the device for its I/O? Do I need to set up each I/O channel in Groov manage first or am I missing something? Thanks in advance!... <less Read/Write I/O using commands to read/write enter I/O unit all at once Forum - Published: This is mainly a question about OptoControl, but as we move our hardware to groov, we are looking at ways to streamline our process. We’ve recently had a lot of issues (I/O units becoming disabled and...moreThis is mainly a question about OptoControl, but as we move our hardware to groov, we are looking at ways to streamline our process. We’ve recently had a lot of issues (I/O units becoming disabled and taking to long to be able to get them communicating again is the primary issue) communicating over serial cables on our LCM4 controllers so we’ve changed how we read/write to the I/O using the the following commands: MoveMixedIoUnitToTable MoveTableToMixedIoUnit MoveAnalogIoUnitToTable MoveTableToA...... <less Node-red energy meter rs485 modbus connection Forum - Published: Hello there, i have some problems with node-re modbus connection via rs485. i have conencted raspberry to Yada dcm6636 energy meter via rs485 port. The port open and communicate each other but in node...moreHello there, i have some problems with node-re modbus connection via rs485. i have conencted raspberry to Yada dcm6636 energy meter via rs485 port. The port open and communicate each other but in node-red no values come and it give time out error. is there know this problem’s solution anyone... <less Updating node-red project API Forum - Published: Hello! I’m working on setting up a CI pipeline for our node-red project and and I would like to automate the deployment to target. I thought maybe I could use the node-red admin API. More specifically...moreHello! I’m working on setting up a CI pipeline for our node-red project and and I would like to automate the deployment to target. I thought maybe I could use the node-red admin API. More specifically the POST /flows. However, when I try to use the API all I get is this: 301 Moved Permanently 301 Moved Permanently nginx/1.20.1 Is the node-red admin API not available on the groov EPIC? Are th...... <less I want to 32 crc and 30 crc and 16 crc with my own polynomial Forum - Published: I want to 32 crc and 30 crc and 16 crc with my own polynomial ,how can I implement this using opto scripting? please reply...I want to 32 crc and 30 crc and 16 crc with my own polynomial ,how can I implement this using opto scripting? please reply... <less EtherNet/IP Configurator for Groov? Forum - Published: I’ve been experimenting this week with the EtherNet/IP Configurator for SNAP PAC hardware. Is it possible to configure similar communication for I/O attached directly to a Groov EPIC-PR1?...I’ve been experimenting this week with the EtherNet/IP Configurator for SNAP PAC hardware. Is it possible to configure similar communication for I/O attached directly to a Groov EPIC-PR1?... <less Understanding high-density channel data for streaming via UDP Forum - Published: Hello, I am trying to understand how to interrupt the high-density channel data located in the OPTOMMP starting at address FFFF F100 0300. According to the structure on page 155 of the manual, this...moreHello, I am trying to understand how to interrupt the high-density channel data located in the OPTOMMP starting at address FFFF F100 0300. According to the structure on page 155 of the manual, this section should have the analog channels value in engineering units and the feature data for digital channels. image898×508 86.9 KB For now, I am trying to read the state of a digital output from a GRV-ODCI-12 card located in slot 0. The controller is a GRV-EPIC-PR1. From looking at the Generic MMP usi...... <less A problem in TCP/IP communication Forum - Published: A R1 controller and 10 temperature and humidity modules communicate through Ethernet. The control strategy in R1 uses an Ethernet communication handle to connect different temperature and humidity...moreA R1 controller and 10 temperature and humidity modules communicate through Ethernet. The control strategy in R1 uses an Ethernet communication handle to connect different temperature and humidity meters by changing the parameters of the communication handle. The R1 controller is the client of TCP communication. To test the effectiveness of TCP communication, I set the polling interval to 100ms, so there is no need for such fast polling during normal use. R1 has been running normally for several...... <less Issue in Opto 22 Groov EPIC PR2 Forum - Published: We are facing critical issues in our current setup involving OPTO 22 GROOV EPIC PR2 PLC and the Ignition Full V8.17 system. Our system configuration includes- OPTO 22 PLC: First Ethernet port- Serum...moreWe are facing critical issues in our current setup involving OPTO 22 GROOV EPIC PR2 PLC and the Ignition Full V8.17 system. Our system configuration includes- OPTO 22 PLC: First Ethernet port- Serum Corporate IP & Second Ethernet port- Local IP of Siemens PLC network. Implemented Data store-and-forward within the OPTO 22 PLC. Established communication between Ignition and 6 nos of Siemens PLCs using OPC devices within the OPTO 22. Integration of 6 databases communication with SQL 2019 in...... <less « PreviousPage 4 of 128Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Trigger Command for Node-RED save to file time period Forum - Published: Hi, I’ve built a data logger that grabs certain points every minute from my Epic and writes the values to a csv file. I use the injector to run this. However, I’m looking for the following to make this...moreHi, I’ve built a data logger that grabs certain points every minute from my Epic and writes the values to a csv file. I use the injector to run this. However, I’m looking for the following to make this enhanced: only pulls the data starting at 8am and stops pulling the data at 4pm. each day it creates a new file log called APM1_Temp_Log_[new date].csv The new file will go to the same path /home/dev/secured/… but will be rename each day to the new date. Right now I’m using the edit-write-edit-n...... <less Problem with Groov View Forum - Published: Hello I have a system running with EPIC PR1(3.4.4) (PacControl, Node-Red, GroovView and MariaDB), it has worked well for a few weeks but lately the GroovView HMI freezes (I have no trends and there is...moreHello I have a system running with EPIC PR1(3.4.4) (PacControl, Node-Red, GroovView and MariaDB), it has worked well for a few weeks but lately the GroovView HMI freezes (I have no trends and there is little data that I show, around of 35 variables) and the controller stops working (Pac Control and Node-Red). To get everything working again I had to restart GroovView (using Groov Manage). I have checked the logs and there is nothing. I have noticed that the CPU temperature is 70 degrees and the ...... <less C++ OptoMMP SDK function for getting/setting engineering units? Forum - Published: Hello, I was wondering if there was a function/method that was part of the C++ OptoMMP SDK that would allow you to either set and/or get the engineering units for a given channel. Basically looking on...moreHello, I was wondering if there was a function/method that was part of the C++ OptoMMP SDK that would allow you to either set and/or get the engineering units for a given channel. Basically looking on how to programmatically get the Unit value from below: image913×1207 54.8 KB The closet functions I could find seemed to be GetPointConfigurationEx4() or SetPointConfigurationEx4(). However the struct passed to this (SIOMM_PointConfigArea4) doesn’t have a Unit member. Tried searching the documentat...... <less Adding a timestamp to data sent to csv file Forum - Published: I’ve created a data logger pulling analog points from my Opto Epic using the following in Node-RED: inject (msg.payload = timestamp) > groov i/o read node > change node (msg.payload to the value of...moreI’ve created a data logger pulling analog points from my Opto Epic using the following in Node-RED: inject (msg.payload = timestamp) > groov i/o read node > change node (msg.payload to the value of “value_name,” & msg.payload) > write file node (path with a file .csv) Right now I get the proper analog value coming in to the csv file as expected but there’s no timestamp allocated to each interval. I suspect I need to add something in the change node but what?? Thanks, Spencer... <less Snap-Pac-R1 and LabVIEW interface Forum - Published: Hey everyone. I am trying to integrate OPTO22 into a previous LabVIEW vi. Does anyone have some examples or previously written LabVIEW vi’s that I can tweak to interface with my current project? I will...moreHey everyone. I am trying to integrate OPTO22 into a previous LabVIEW vi. Does anyone have some examples or previously written LabVIEW vi’s that I can tweak to interface with my current project? I will need to connect over ethernet and cannot use SNMP. It will need to be another communication format. Any help would be greatly appreciate as I am new to both LabVIEW and OPTO22 interface. Kevin... <less Opto Epic I/O points collected in a data-logger to csv file Forum - Published: I’m trying to build a simple data logger collecting I/O points (mostly just analog values), from the Opto Epic (we have PAC Controller also. Basically need a timestamp, roughly 10 analog points collected...moreI’m trying to build a simple data logger collecting I/O points (mostly just analog values), from the Opto Epic (we have PAC Controller also. Basically need a timestamp, roughly 10 analog points collected every 5 seconds, put into one CSV file (each day would be a new file name based on date: 2024-01-23) and within the csv file it would have a column for the timestamp, value 1, value 2, value 3…etc. Much appreciated.... <less Deleting Unused Images In Groov View Forum - Published: Hey Folks. So, I have been creating and adding images to my Groov View project. Its looking good! However, I now have some images I’m not using. I’d like to find the folder these images I import in are...moreHey Folks. So, I have been creating and adding images to my Groov View project. Its looking good! However, I now have some images I’m not using. I’d like to find the folder these images I import in are stored and delete them. Any idea where this folder would be? Thank you.... <less How to use the GRV-IDCIS-12 to measure RPMS Forum - Published: Hello. I am having difficulties trying to program this module to measure RPMS. I am using a proximity sensor that is being toggled by a metal screw on a plastic rotating shaft. This module doesn’t have...moreHello. I am having difficulties trying to program this module to measure RPMS. I am using a proximity sensor that is being toggled by a metal screw on a plastic rotating shaft. This module doesn’t have the features to set so I am trying to get around that for the time being. I am trying to have the screw start a count-up timer that keeps restarting when it sees it again. I want to input that value from the count-up timer into a formula to output value. I am not much of a programmer at all so any...... <less Groov View Drawings and Things Forum - Published: Good afternoon. I’m still using the Trial Version of Groov View. I’m trying to build an Overview of our Facilities to illustrate machine state and data. I’m wondering if there is more drawing tools in...moreGood afternoon. I’m still using the Trial Version of Groov View. I’m trying to build an Overview of our Facilities to illustrate machine state and data. I’m wondering if there is more drawing tools in the full version of Groov View. I find I’m very limited in drawing simple objects. I can import images, but I don’t have an option to draw for example a line or a line that is on a diagonal. I don’t really see an option to draw anything. I can place a Rectangle or an Oval. That is about it. I’m gue...... <less goovView Trends Float variable too long Forum - Published: I took the EPIC class last year, August class, I asked how to truncate float variables in groovView trend graphs. Terry said he had a solution in your forums. I couldn’t find it. Please give me...moreI took the EPIC class last year, August class, I asked how to truncate float variables in groovView trend graphs. Terry said he had a solution in your forums. I couldn’t find it. Please give me directions to shorten the decimal places on float variables when using a trend in groovView. 15 decimal places is too much, not just for groovView trends, but also when I send an event as a text it makes it difficult to see on the phone screen. I’m using EPIC PR1 with Firmware 3.5 and PAC Project 10.5b ru...... <less Printer Interface via an EPIC Controller Forum - Published: Have an existing system using an EPIC controller (PACProject) with Groov View via the HDMI port that needs to print reports. The intent is to try to do this without adding a PC to the system. I’ve done...moreHave an existing system using an EPIC controller (PACProject) with Groov View via the HDMI port that needs to print reports. The intent is to try to do this without adding a PC to the system. I’ve done ASCII to Serial (RS232) Printers years ago (via PACProject and an PAC-R) BUT serial printers are not as common today (most are for labels or receipts). Is there a way (or has anybody already done this) via Node-Red, PACControl, shell access, etc. that we can send our Text Files to a standard Ether...... <less Question On Trending in Groov View Forum - Published: Good morning. My situation is… I’m using the trial version of Groov View Server for Windows on a PC currently. I have a lot of trends that are all working nicely reading PLC tags from various sources...moreGood morning. My situation is… I’m using the trial version of Groov View Server for Windows on a PC currently. I have a lot of trends that are all working nicely reading PLC tags from various sources (Coming from Node-Red EthernetIP Nodes). Currently I have to re-start the Groov Server and reopen Groov View every two hours as it’s a trial version. If I restart the server immediately upon timing out, then I retain my older data. If it sits for a bit before reopening, I lose my older data. My ques...... <less Sensors that can tap into (so we can monitor and/or manipulate) badge access to one of our more sophisticated machine shop devices, like a laser cutter Forum - Published: We’re starting our Industry 4.0 transformation with the groov RIO (& eventually EPIC) product line. We’re looking for sensors that can tap into (so we can monitor and/or manipulate) badge access to one...moreWe’re starting our Industry 4.0 transformation with the groov RIO (& eventually EPIC) product line. We’re looking for sensors that can tap into (so we can monitor and/or manipulate) badge access to one of our more sophisticated machine shop devices, like a laser cutter. We went to ensure that the technician is qualified to operate the equipment. Any thoughts or suggestions?... <less RIO Device Scan unavailable? Forum - Published: Hello everyone, Trying to play with getting this RIO (MM1001-10) going with Codesys. I have successfully connected to it and gone online, however I cannot seem to scan the device for its I/O? Do I...moreHello everyone, Trying to play with getting this RIO (MM1001-10) going with Codesys. I have successfully connected to it and gone online, however I cannot seem to scan the device for its I/O? Do I need to set up each I/O channel in Groov manage first or am I missing something? Thanks in advance!... <less Read/Write I/O using commands to read/write enter I/O unit all at once Forum - Published: This is mainly a question about OptoControl, but as we move our hardware to groov, we are looking at ways to streamline our process. We’ve recently had a lot of issues (I/O units becoming disabled and...moreThis is mainly a question about OptoControl, but as we move our hardware to groov, we are looking at ways to streamline our process. We’ve recently had a lot of issues (I/O units becoming disabled and taking to long to be able to get them communicating again is the primary issue) communicating over serial cables on our LCM4 controllers so we’ve changed how we read/write to the I/O using the the following commands: MoveMixedIoUnitToTable MoveTableToMixedIoUnit MoveAnalogIoUnitToTable MoveTableToA...... <less Node-red energy meter rs485 modbus connection Forum - Published: Hello there, i have some problems with node-re modbus connection via rs485. i have conencted raspberry to Yada dcm6636 energy meter via rs485 port. The port open and communicate each other but in node...moreHello there, i have some problems with node-re modbus connection via rs485. i have conencted raspberry to Yada dcm6636 energy meter via rs485 port. The port open and communicate each other but in node-red no values come and it give time out error. is there know this problem’s solution anyone... <less Updating node-red project API Forum - Published: Hello! I’m working on setting up a CI pipeline for our node-red project and and I would like to automate the deployment to target. I thought maybe I could use the node-red admin API. More specifically...moreHello! I’m working on setting up a CI pipeline for our node-red project and and I would like to automate the deployment to target. I thought maybe I could use the node-red admin API. More specifically the POST /flows. However, when I try to use the API all I get is this: 301 Moved Permanently 301 Moved Permanently nginx/1.20.1 Is the node-red admin API not available on the groov EPIC? Are th...... <less I want to 32 crc and 30 crc and 16 crc with my own polynomial Forum - Published: I want to 32 crc and 30 crc and 16 crc with my own polynomial ,how can I implement this using opto scripting? please reply...I want to 32 crc and 30 crc and 16 crc with my own polynomial ,how can I implement this using opto scripting? please reply... <less EtherNet/IP Configurator for Groov? Forum - Published: I’ve been experimenting this week with the EtherNet/IP Configurator for SNAP PAC hardware. Is it possible to configure similar communication for I/O attached directly to a Groov EPIC-PR1?...I’ve been experimenting this week with the EtherNet/IP Configurator for SNAP PAC hardware. Is it possible to configure similar communication for I/O attached directly to a Groov EPIC-PR1?... <less Understanding high-density channel data for streaming via UDP Forum - Published: Hello, I am trying to understand how to interrupt the high-density channel data located in the OPTOMMP starting at address FFFF F100 0300. According to the structure on page 155 of the manual, this...moreHello, I am trying to understand how to interrupt the high-density channel data located in the OPTOMMP starting at address FFFF F100 0300. According to the structure on page 155 of the manual, this section should have the analog channels value in engineering units and the feature data for digital channels. image898×508 86.9 KB For now, I am trying to read the state of a digital output from a GRV-ODCI-12 card located in slot 0. The controller is a GRV-EPIC-PR1. From looking at the Generic MMP usi...... <less A problem in TCP/IP communication Forum - Published: A R1 controller and 10 temperature and humidity modules communicate through Ethernet. The control strategy in R1 uses an Ethernet communication handle to connect different temperature and humidity...moreA R1 controller and 10 temperature and humidity modules communicate through Ethernet. The control strategy in R1 uses an Ethernet communication handle to connect different temperature and humidity meters by changing the parameters of the communication handle. The R1 controller is the client of TCP communication. To test the effectiveness of TCP communication, I set the polling interval to 100ms, so there is no need for such fast polling during normal use. R1 has been running normally for several...... <less Issue in Opto 22 Groov EPIC PR2 Forum - Published: We are facing critical issues in our current setup involving OPTO 22 GROOV EPIC PR2 PLC and the Ignition Full V8.17 system. Our system configuration includes- OPTO 22 PLC: First Ethernet port- Serum...moreWe are facing critical issues in our current setup involving OPTO 22 GROOV EPIC PR2 PLC and the Ignition Full V8.17 system. Our system configuration includes- OPTO 22 PLC: First Ethernet port- Serum Corporate IP & Second Ethernet port- Local IP of Siemens PLC network. Implemented Data store-and-forward within the OPTO 22 PLC. Established communication between Ignition and 6 nos of Siemens PLCs using OPC devices within the OPTO 22. Integration of 6 databases communication with SQL 2019 in...... <less « PreviousPage 4 of 128Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Problem with Groov View Forum - Published: Hello I have a system running with EPIC PR1(3.4.4) (PacControl, Node-Red, GroovView and MariaDB), it has worked well for a few weeks but lately the GroovView HMI freezes (I have no trends and there is...moreHello I have a system running with EPIC PR1(3.4.4) (PacControl, Node-Red, GroovView and MariaDB), it has worked well for a few weeks but lately the GroovView HMI freezes (I have no trends and there is little data that I show, around of 35 variables) and the controller stops working (Pac Control and Node-Red). To get everything working again I had to restart GroovView (using Groov Manage). I have checked the logs and there is nothing. I have noticed that the CPU temperature is 70 degrees and the ...... <less C++ OptoMMP SDK function for getting/setting engineering units? Forum - Published: Hello, I was wondering if there was a function/method that was part of the C++ OptoMMP SDK that would allow you to either set and/or get the engineering units for a given channel. Basically looking on...moreHello, I was wondering if there was a function/method that was part of the C++ OptoMMP SDK that would allow you to either set and/or get the engineering units for a given channel. Basically looking on how to programmatically get the Unit value from below: image913×1207 54.8 KB The closet functions I could find seemed to be GetPointConfigurationEx4() or SetPointConfigurationEx4(). However the struct passed to this (SIOMM_PointConfigArea4) doesn’t have a Unit member. Tried searching the documentat...... <less Adding a timestamp to data sent to csv file Forum - Published: I’ve created a data logger pulling analog points from my Opto Epic using the following in Node-RED: inject (msg.payload = timestamp) > groov i/o read node > change node (msg.payload to the value of...moreI’ve created a data logger pulling analog points from my Opto Epic using the following in Node-RED: inject (msg.payload = timestamp) > groov i/o read node > change node (msg.payload to the value of “value_name,” & msg.payload) > write file node (path with a file .csv) Right now I get the proper analog value coming in to the csv file as expected but there’s no timestamp allocated to each interval. I suspect I need to add something in the change node but what?? Thanks, Spencer... <less Snap-Pac-R1 and LabVIEW interface Forum - Published: Hey everyone. I am trying to integrate OPTO22 into a previous LabVIEW vi. Does anyone have some examples or previously written LabVIEW vi’s that I can tweak to interface with my current project? I will...moreHey everyone. I am trying to integrate OPTO22 into a previous LabVIEW vi. Does anyone have some examples or previously written LabVIEW vi’s that I can tweak to interface with my current project? I will need to connect over ethernet and cannot use SNMP. It will need to be another communication format. Any help would be greatly appreciate as I am new to both LabVIEW and OPTO22 interface. Kevin... <less Opto Epic I/O points collected in a data-logger to csv file Forum - Published: I’m trying to build a simple data logger collecting I/O points (mostly just analog values), from the Opto Epic (we have PAC Controller also. Basically need a timestamp, roughly 10 analog points collected...moreI’m trying to build a simple data logger collecting I/O points (mostly just analog values), from the Opto Epic (we have PAC Controller also. Basically need a timestamp, roughly 10 analog points collected every 5 seconds, put into one CSV file (each day would be a new file name based on date: 2024-01-23) and within the csv file it would have a column for the timestamp, value 1, value 2, value 3…etc. Much appreciated.... <less Deleting Unused Images In Groov View Forum - Published: Hey Folks. So, I have been creating and adding images to my Groov View project. Its looking good! However, I now have some images I’m not using. I’d like to find the folder these images I import in are...moreHey Folks. So, I have been creating and adding images to my Groov View project. Its looking good! However, I now have some images I’m not using. I’d like to find the folder these images I import in are stored and delete them. Any idea where this folder would be? Thank you.... <less How to use the GRV-IDCIS-12 to measure RPMS Forum - Published: Hello. I am having difficulties trying to program this module to measure RPMS. I am using a proximity sensor that is being toggled by a metal screw on a plastic rotating shaft. This module doesn’t have...moreHello. I am having difficulties trying to program this module to measure RPMS. I am using a proximity sensor that is being toggled by a metal screw on a plastic rotating shaft. This module doesn’t have the features to set so I am trying to get around that for the time being. I am trying to have the screw start a count-up timer that keeps restarting when it sees it again. I want to input that value from the count-up timer into a formula to output value. I am not much of a programmer at all so any...... <less Groov View Drawings and Things Forum - Published: Good afternoon. I’m still using the Trial Version of Groov View. I’m trying to build an Overview of our Facilities to illustrate machine state and data. I’m wondering if there is more drawing tools in...moreGood afternoon. I’m still using the Trial Version of Groov View. I’m trying to build an Overview of our Facilities to illustrate machine state and data. I’m wondering if there is more drawing tools in the full version of Groov View. I find I’m very limited in drawing simple objects. I can import images, but I don’t have an option to draw for example a line or a line that is on a diagonal. I don’t really see an option to draw anything. I can place a Rectangle or an Oval. That is about it. I’m gue...... <less goovView Trends Float variable too long Forum - Published: I took the EPIC class last year, August class, I asked how to truncate float variables in groovView trend graphs. Terry said he had a solution in your forums. I couldn’t find it. Please give me...moreI took the EPIC class last year, August class, I asked how to truncate float variables in groovView trend graphs. Terry said he had a solution in your forums. I couldn’t find it. Please give me directions to shorten the decimal places on float variables when using a trend in groovView. 15 decimal places is too much, not just for groovView trends, but also when I send an event as a text it makes it difficult to see on the phone screen. I’m using EPIC PR1 with Firmware 3.5 and PAC Project 10.5b ru...... <less Printer Interface via an EPIC Controller Forum - Published: Have an existing system using an EPIC controller (PACProject) with Groov View via the HDMI port that needs to print reports. The intent is to try to do this without adding a PC to the system. I’ve done...moreHave an existing system using an EPIC controller (PACProject) with Groov View via the HDMI port that needs to print reports. The intent is to try to do this without adding a PC to the system. I’ve done ASCII to Serial (RS232) Printers years ago (via PACProject and an PAC-R) BUT serial printers are not as common today (most are for labels or receipts). Is there a way (or has anybody already done this) via Node-Red, PACControl, shell access, etc. that we can send our Text Files to a standard Ether...... <less Question On Trending in Groov View Forum - Published: Good morning. My situation is… I’m using the trial version of Groov View Server for Windows on a PC currently. I have a lot of trends that are all working nicely reading PLC tags from various sources...moreGood morning. My situation is… I’m using the trial version of Groov View Server for Windows on a PC currently. I have a lot of trends that are all working nicely reading PLC tags from various sources (Coming from Node-Red EthernetIP Nodes). Currently I have to re-start the Groov Server and reopen Groov View every two hours as it’s a trial version. If I restart the server immediately upon timing out, then I retain my older data. If it sits for a bit before reopening, I lose my older data. My ques...... <less Sensors that can tap into (so we can monitor and/or manipulate) badge access to one of our more sophisticated machine shop devices, like a laser cutter Forum - Published: We’re starting our Industry 4.0 transformation with the groov RIO (& eventually EPIC) product line. We’re looking for sensors that can tap into (so we can monitor and/or manipulate) badge access to one...moreWe’re starting our Industry 4.0 transformation with the groov RIO (& eventually EPIC) product line. We’re looking for sensors that can tap into (so we can monitor and/or manipulate) badge access to one of our more sophisticated machine shop devices, like a laser cutter. We went to ensure that the technician is qualified to operate the equipment. Any thoughts or suggestions?... <less RIO Device Scan unavailable? Forum - Published: Hello everyone, Trying to play with getting this RIO (MM1001-10) going with Codesys. I have successfully connected to it and gone online, however I cannot seem to scan the device for its I/O? Do I...moreHello everyone, Trying to play with getting this RIO (MM1001-10) going with Codesys. I have successfully connected to it and gone online, however I cannot seem to scan the device for its I/O? Do I need to set up each I/O channel in Groov manage first or am I missing something? Thanks in advance!... <less Read/Write I/O using commands to read/write enter I/O unit all at once Forum - Published: This is mainly a question about OptoControl, but as we move our hardware to groov, we are looking at ways to streamline our process. We’ve recently had a lot of issues (I/O units becoming disabled and...moreThis is mainly a question about OptoControl, but as we move our hardware to groov, we are looking at ways to streamline our process. We’ve recently had a lot of issues (I/O units becoming disabled and taking to long to be able to get them communicating again is the primary issue) communicating over serial cables on our LCM4 controllers so we’ve changed how we read/write to the I/O using the the following commands: MoveMixedIoUnitToTable MoveTableToMixedIoUnit MoveAnalogIoUnitToTable MoveTableToA...... <less Node-red energy meter rs485 modbus connection Forum - Published: Hello there, i have some problems with node-re modbus connection via rs485. i have conencted raspberry to Yada dcm6636 energy meter via rs485 port. The port open and communicate each other but in node...moreHello there, i have some problems with node-re modbus connection via rs485. i have conencted raspberry to Yada dcm6636 energy meter via rs485 port. The port open and communicate each other but in node-red no values come and it give time out error. is there know this problem’s solution anyone... <less Updating node-red project API Forum - Published: Hello! I’m working on setting up a CI pipeline for our node-red project and and I would like to automate the deployment to target. I thought maybe I could use the node-red admin API. More specifically...moreHello! I’m working on setting up a CI pipeline for our node-red project and and I would like to automate the deployment to target. I thought maybe I could use the node-red admin API. More specifically the POST /flows. However, when I try to use the API all I get is this: 301 Moved Permanently 301 Moved Permanently nginx/1.20.1 Is the node-red admin API not available on the groov EPIC? Are th...... <less I want to 32 crc and 30 crc and 16 crc with my own polynomial Forum - Published: I want to 32 crc and 30 crc and 16 crc with my own polynomial ,how can I implement this using opto scripting? please reply...I want to 32 crc and 30 crc and 16 crc with my own polynomial ,how can I implement this using opto scripting? please reply... <less EtherNet/IP Configurator for Groov? Forum - Published: I’ve been experimenting this week with the EtherNet/IP Configurator for SNAP PAC hardware. Is it possible to configure similar communication for I/O attached directly to a Groov EPIC-PR1?...I’ve been experimenting this week with the EtherNet/IP Configurator for SNAP PAC hardware. Is it possible to configure similar communication for I/O attached directly to a Groov EPIC-PR1?... <less Understanding high-density channel data for streaming via UDP Forum - Published: Hello, I am trying to understand how to interrupt the high-density channel data located in the OPTOMMP starting at address FFFF F100 0300. According to the structure on page 155 of the manual, this...moreHello, I am trying to understand how to interrupt the high-density channel data located in the OPTOMMP starting at address FFFF F100 0300. According to the structure on page 155 of the manual, this section should have the analog channels value in engineering units and the feature data for digital channels. image898×508 86.9 KB For now, I am trying to read the state of a digital output from a GRV-ODCI-12 card located in slot 0. The controller is a GRV-EPIC-PR1. From looking at the Generic MMP usi...... <less A problem in TCP/IP communication Forum - Published: A R1 controller and 10 temperature and humidity modules communicate through Ethernet. The control strategy in R1 uses an Ethernet communication handle to connect different temperature and humidity...moreA R1 controller and 10 temperature and humidity modules communicate through Ethernet. The control strategy in R1 uses an Ethernet communication handle to connect different temperature and humidity meters by changing the parameters of the communication handle. The R1 controller is the client of TCP communication. To test the effectiveness of TCP communication, I set the polling interval to 100ms, so there is no need for such fast polling during normal use. R1 has been running normally for several...... <less Issue in Opto 22 Groov EPIC PR2 Forum - Published: We are facing critical issues in our current setup involving OPTO 22 GROOV EPIC PR2 PLC and the Ignition Full V8.17 system. Our system configuration includes- OPTO 22 PLC: First Ethernet port- Serum...moreWe are facing critical issues in our current setup involving OPTO 22 GROOV EPIC PR2 PLC and the Ignition Full V8.17 system. Our system configuration includes- OPTO 22 PLC: First Ethernet port- Serum Corporate IP & Second Ethernet port- Local IP of Siemens PLC network. Implemented Data store-and-forward within the OPTO 22 PLC. Established communication between Ignition and 6 nos of Siemens PLCs using OPC devices within the OPTO 22. Integration of 6 databases communication with SQL 2019 in...... <less « PreviousPage 4 of 128Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
C++ OptoMMP SDK function for getting/setting engineering units? Forum - Published: Hello, I was wondering if there was a function/method that was part of the C++ OptoMMP SDK that would allow you to either set and/or get the engineering units for a given channel. Basically looking on...moreHello, I was wondering if there was a function/method that was part of the C++ OptoMMP SDK that would allow you to either set and/or get the engineering units for a given channel. Basically looking on how to programmatically get the Unit value from below: image913×1207 54.8 KB The closet functions I could find seemed to be GetPointConfigurationEx4() or SetPointConfigurationEx4(). However the struct passed to this (SIOMM_PointConfigArea4) doesn’t have a Unit member. Tried searching the documentat...... <less Adding a timestamp to data sent to csv file Forum - Published: I’ve created a data logger pulling analog points from my Opto Epic using the following in Node-RED: inject (msg.payload = timestamp) > groov i/o read node > change node (msg.payload to the value of...moreI’ve created a data logger pulling analog points from my Opto Epic using the following in Node-RED: inject (msg.payload = timestamp) > groov i/o read node > change node (msg.payload to the value of “value_name,” & msg.payload) > write file node (path with a file .csv) Right now I get the proper analog value coming in to the csv file as expected but there’s no timestamp allocated to each interval. I suspect I need to add something in the change node but what?? Thanks, Spencer... <less Snap-Pac-R1 and LabVIEW interface Forum - Published: Hey everyone. I am trying to integrate OPTO22 into a previous LabVIEW vi. Does anyone have some examples or previously written LabVIEW vi’s that I can tweak to interface with my current project? I will...moreHey everyone. I am trying to integrate OPTO22 into a previous LabVIEW vi. Does anyone have some examples or previously written LabVIEW vi’s that I can tweak to interface with my current project? I will need to connect over ethernet and cannot use SNMP. It will need to be another communication format. Any help would be greatly appreciate as I am new to both LabVIEW and OPTO22 interface. Kevin... <less Opto Epic I/O points collected in a data-logger to csv file Forum - Published: I’m trying to build a simple data logger collecting I/O points (mostly just analog values), from the Opto Epic (we have PAC Controller also. Basically need a timestamp, roughly 10 analog points collected...moreI’m trying to build a simple data logger collecting I/O points (mostly just analog values), from the Opto Epic (we have PAC Controller also. Basically need a timestamp, roughly 10 analog points collected every 5 seconds, put into one CSV file (each day would be a new file name based on date: 2024-01-23) and within the csv file it would have a column for the timestamp, value 1, value 2, value 3…etc. Much appreciated.... <less Deleting Unused Images In Groov View Forum - Published: Hey Folks. So, I have been creating and adding images to my Groov View project. Its looking good! However, I now have some images I’m not using. I’d like to find the folder these images I import in are...moreHey Folks. So, I have been creating and adding images to my Groov View project. Its looking good! However, I now have some images I’m not using. I’d like to find the folder these images I import in are stored and delete them. Any idea where this folder would be? Thank you.... <less How to use the GRV-IDCIS-12 to measure RPMS Forum - Published: Hello. I am having difficulties trying to program this module to measure RPMS. I am using a proximity sensor that is being toggled by a metal screw on a plastic rotating shaft. This module doesn’t have...moreHello. I am having difficulties trying to program this module to measure RPMS. I am using a proximity sensor that is being toggled by a metal screw on a plastic rotating shaft. This module doesn’t have the features to set so I am trying to get around that for the time being. I am trying to have the screw start a count-up timer that keeps restarting when it sees it again. I want to input that value from the count-up timer into a formula to output value. I am not much of a programmer at all so any...... <less Groov View Drawings and Things Forum - Published: Good afternoon. I’m still using the Trial Version of Groov View. I’m trying to build an Overview of our Facilities to illustrate machine state and data. I’m wondering if there is more drawing tools in...moreGood afternoon. I’m still using the Trial Version of Groov View. I’m trying to build an Overview of our Facilities to illustrate machine state and data. I’m wondering if there is more drawing tools in the full version of Groov View. I find I’m very limited in drawing simple objects. I can import images, but I don’t have an option to draw for example a line or a line that is on a diagonal. I don’t really see an option to draw anything. I can place a Rectangle or an Oval. That is about it. I’m gue...... <less goovView Trends Float variable too long Forum - Published: I took the EPIC class last year, August class, I asked how to truncate float variables in groovView trend graphs. Terry said he had a solution in your forums. I couldn’t find it. Please give me...moreI took the EPIC class last year, August class, I asked how to truncate float variables in groovView trend graphs. Terry said he had a solution in your forums. I couldn’t find it. Please give me directions to shorten the decimal places on float variables when using a trend in groovView. 15 decimal places is too much, not just for groovView trends, but also when I send an event as a text it makes it difficult to see on the phone screen. I’m using EPIC PR1 with Firmware 3.5 and PAC Project 10.5b ru...... <less Printer Interface via an EPIC Controller Forum - Published: Have an existing system using an EPIC controller (PACProject) with Groov View via the HDMI port that needs to print reports. The intent is to try to do this without adding a PC to the system. I’ve done...moreHave an existing system using an EPIC controller (PACProject) with Groov View via the HDMI port that needs to print reports. The intent is to try to do this without adding a PC to the system. I’ve done ASCII to Serial (RS232) Printers years ago (via PACProject and an PAC-R) BUT serial printers are not as common today (most are for labels or receipts). Is there a way (or has anybody already done this) via Node-Red, PACControl, shell access, etc. that we can send our Text Files to a standard Ether...... <less Question On Trending in Groov View Forum - Published: Good morning. My situation is… I’m using the trial version of Groov View Server for Windows on a PC currently. I have a lot of trends that are all working nicely reading PLC tags from various sources...moreGood morning. My situation is… I’m using the trial version of Groov View Server for Windows on a PC currently. I have a lot of trends that are all working nicely reading PLC tags from various sources (Coming from Node-Red EthernetIP Nodes). Currently I have to re-start the Groov Server and reopen Groov View every two hours as it’s a trial version. If I restart the server immediately upon timing out, then I retain my older data. If it sits for a bit before reopening, I lose my older data. My ques...... <less Sensors that can tap into (so we can monitor and/or manipulate) badge access to one of our more sophisticated machine shop devices, like a laser cutter Forum - Published: We’re starting our Industry 4.0 transformation with the groov RIO (& eventually EPIC) product line. We’re looking for sensors that can tap into (so we can monitor and/or manipulate) badge access to one...moreWe’re starting our Industry 4.0 transformation with the groov RIO (& eventually EPIC) product line. We’re looking for sensors that can tap into (so we can monitor and/or manipulate) badge access to one of our more sophisticated machine shop devices, like a laser cutter. We went to ensure that the technician is qualified to operate the equipment. Any thoughts or suggestions?... <less RIO Device Scan unavailable? Forum - Published: Hello everyone, Trying to play with getting this RIO (MM1001-10) going with Codesys. I have successfully connected to it and gone online, however I cannot seem to scan the device for its I/O? Do I...moreHello everyone, Trying to play with getting this RIO (MM1001-10) going with Codesys. I have successfully connected to it and gone online, however I cannot seem to scan the device for its I/O? Do I need to set up each I/O channel in Groov manage first or am I missing something? Thanks in advance!... <less Read/Write I/O using commands to read/write enter I/O unit all at once Forum - Published: This is mainly a question about OptoControl, but as we move our hardware to groov, we are looking at ways to streamline our process. We’ve recently had a lot of issues (I/O units becoming disabled and...moreThis is mainly a question about OptoControl, but as we move our hardware to groov, we are looking at ways to streamline our process. We’ve recently had a lot of issues (I/O units becoming disabled and taking to long to be able to get them communicating again is the primary issue) communicating over serial cables on our LCM4 controllers so we’ve changed how we read/write to the I/O using the the following commands: MoveMixedIoUnitToTable MoveTableToMixedIoUnit MoveAnalogIoUnitToTable MoveTableToA...... <less Node-red energy meter rs485 modbus connection Forum - Published: Hello there, i have some problems with node-re modbus connection via rs485. i have conencted raspberry to Yada dcm6636 energy meter via rs485 port. The port open and communicate each other but in node...moreHello there, i have some problems with node-re modbus connection via rs485. i have conencted raspberry to Yada dcm6636 energy meter via rs485 port. The port open and communicate each other but in node-red no values come and it give time out error. is there know this problem’s solution anyone... <less Updating node-red project API Forum - Published: Hello! I’m working on setting up a CI pipeline for our node-red project and and I would like to automate the deployment to target. I thought maybe I could use the node-red admin API. More specifically...moreHello! I’m working on setting up a CI pipeline for our node-red project and and I would like to automate the deployment to target. I thought maybe I could use the node-red admin API. More specifically the POST /flows. However, when I try to use the API all I get is this: 301 Moved Permanently 301 Moved Permanently nginx/1.20.1 Is the node-red admin API not available on the groov EPIC? Are th...... <less I want to 32 crc and 30 crc and 16 crc with my own polynomial Forum - Published: I want to 32 crc and 30 crc and 16 crc with my own polynomial ,how can I implement this using opto scripting? please reply...I want to 32 crc and 30 crc and 16 crc with my own polynomial ,how can I implement this using opto scripting? please reply... <less EtherNet/IP Configurator for Groov? Forum - Published: I’ve been experimenting this week with the EtherNet/IP Configurator for SNAP PAC hardware. Is it possible to configure similar communication for I/O attached directly to a Groov EPIC-PR1?...I’ve been experimenting this week with the EtherNet/IP Configurator for SNAP PAC hardware. Is it possible to configure similar communication for I/O attached directly to a Groov EPIC-PR1?... <less Understanding high-density channel data for streaming via UDP Forum - Published: Hello, I am trying to understand how to interrupt the high-density channel data located in the OPTOMMP starting at address FFFF F100 0300. According to the structure on page 155 of the manual, this...moreHello, I am trying to understand how to interrupt the high-density channel data located in the OPTOMMP starting at address FFFF F100 0300. According to the structure on page 155 of the manual, this section should have the analog channels value in engineering units and the feature data for digital channels. image898×508 86.9 KB For now, I am trying to read the state of a digital output from a GRV-ODCI-12 card located in slot 0. The controller is a GRV-EPIC-PR1. From looking at the Generic MMP usi...... <less A problem in TCP/IP communication Forum - Published: A R1 controller and 10 temperature and humidity modules communicate through Ethernet. The control strategy in R1 uses an Ethernet communication handle to connect different temperature and humidity...moreA R1 controller and 10 temperature and humidity modules communicate through Ethernet. The control strategy in R1 uses an Ethernet communication handle to connect different temperature and humidity meters by changing the parameters of the communication handle. The R1 controller is the client of TCP communication. To test the effectiveness of TCP communication, I set the polling interval to 100ms, so there is no need for such fast polling during normal use. R1 has been running normally for several...... <less Issue in Opto 22 Groov EPIC PR2 Forum - Published: We are facing critical issues in our current setup involving OPTO 22 GROOV EPIC PR2 PLC and the Ignition Full V8.17 system. Our system configuration includes- OPTO 22 PLC: First Ethernet port- Serum...moreWe are facing critical issues in our current setup involving OPTO 22 GROOV EPIC PR2 PLC and the Ignition Full V8.17 system. Our system configuration includes- OPTO 22 PLC: First Ethernet port- Serum Corporate IP & Second Ethernet port- Local IP of Siemens PLC network. Implemented Data store-and-forward within the OPTO 22 PLC. Established communication between Ignition and 6 nos of Siemens PLCs using OPC devices within the OPTO 22. Integration of 6 databases communication with SQL 2019 in...... <less « PreviousPage 4 of 128Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Adding a timestamp to data sent to csv file Forum - Published: I’ve created a data logger pulling analog points from my Opto Epic using the following in Node-RED: inject (msg.payload = timestamp) > groov i/o read node > change node (msg.payload to the value of...moreI’ve created a data logger pulling analog points from my Opto Epic using the following in Node-RED: inject (msg.payload = timestamp) > groov i/o read node > change node (msg.payload to the value of “value_name,” & msg.payload) > write file node (path with a file .csv) Right now I get the proper analog value coming in to the csv file as expected but there’s no timestamp allocated to each interval. I suspect I need to add something in the change node but what?? Thanks, Spencer... <less Snap-Pac-R1 and LabVIEW interface Forum - Published: Hey everyone. I am trying to integrate OPTO22 into a previous LabVIEW vi. Does anyone have some examples or previously written LabVIEW vi’s that I can tweak to interface with my current project? I will...moreHey everyone. I am trying to integrate OPTO22 into a previous LabVIEW vi. Does anyone have some examples or previously written LabVIEW vi’s that I can tweak to interface with my current project? I will need to connect over ethernet and cannot use SNMP. It will need to be another communication format. Any help would be greatly appreciate as I am new to both LabVIEW and OPTO22 interface. Kevin... <less Opto Epic I/O points collected in a data-logger to csv file Forum - Published: I’m trying to build a simple data logger collecting I/O points (mostly just analog values), from the Opto Epic (we have PAC Controller also. Basically need a timestamp, roughly 10 analog points collected...moreI’m trying to build a simple data logger collecting I/O points (mostly just analog values), from the Opto Epic (we have PAC Controller also. Basically need a timestamp, roughly 10 analog points collected every 5 seconds, put into one CSV file (each day would be a new file name based on date: 2024-01-23) and within the csv file it would have a column for the timestamp, value 1, value 2, value 3…etc. Much appreciated.... <less Deleting Unused Images In Groov View Forum - Published: Hey Folks. So, I have been creating and adding images to my Groov View project. Its looking good! However, I now have some images I’m not using. I’d like to find the folder these images I import in are...moreHey Folks. So, I have been creating and adding images to my Groov View project. Its looking good! However, I now have some images I’m not using. I’d like to find the folder these images I import in are stored and delete them. Any idea where this folder would be? Thank you.... <less How to use the GRV-IDCIS-12 to measure RPMS Forum - Published: Hello. I am having difficulties trying to program this module to measure RPMS. I am using a proximity sensor that is being toggled by a metal screw on a plastic rotating shaft. This module doesn’t have...moreHello. I am having difficulties trying to program this module to measure RPMS. I am using a proximity sensor that is being toggled by a metal screw on a plastic rotating shaft. This module doesn’t have the features to set so I am trying to get around that for the time being. I am trying to have the screw start a count-up timer that keeps restarting when it sees it again. I want to input that value from the count-up timer into a formula to output value. I am not much of a programmer at all so any...... <less Groov View Drawings and Things Forum - Published: Good afternoon. I’m still using the Trial Version of Groov View. I’m trying to build an Overview of our Facilities to illustrate machine state and data. I’m wondering if there is more drawing tools in...moreGood afternoon. I’m still using the Trial Version of Groov View. I’m trying to build an Overview of our Facilities to illustrate machine state and data. I’m wondering if there is more drawing tools in the full version of Groov View. I find I’m very limited in drawing simple objects. I can import images, but I don’t have an option to draw for example a line or a line that is on a diagonal. I don’t really see an option to draw anything. I can place a Rectangle or an Oval. That is about it. I’m gue...... <less goovView Trends Float variable too long Forum - Published: I took the EPIC class last year, August class, I asked how to truncate float variables in groovView trend graphs. Terry said he had a solution in your forums. I couldn’t find it. Please give me...moreI took the EPIC class last year, August class, I asked how to truncate float variables in groovView trend graphs. Terry said he had a solution in your forums. I couldn’t find it. Please give me directions to shorten the decimal places on float variables when using a trend in groovView. 15 decimal places is too much, not just for groovView trends, but also when I send an event as a text it makes it difficult to see on the phone screen. I’m using EPIC PR1 with Firmware 3.5 and PAC Project 10.5b ru...... <less Printer Interface via an EPIC Controller Forum - Published: Have an existing system using an EPIC controller (PACProject) with Groov View via the HDMI port that needs to print reports. The intent is to try to do this without adding a PC to the system. I’ve done...moreHave an existing system using an EPIC controller (PACProject) with Groov View via the HDMI port that needs to print reports. The intent is to try to do this without adding a PC to the system. I’ve done ASCII to Serial (RS232) Printers years ago (via PACProject and an PAC-R) BUT serial printers are not as common today (most are for labels or receipts). Is there a way (or has anybody already done this) via Node-Red, PACControl, shell access, etc. that we can send our Text Files to a standard Ether...... <less Question On Trending in Groov View Forum - Published: Good morning. My situation is… I’m using the trial version of Groov View Server for Windows on a PC currently. I have a lot of trends that are all working nicely reading PLC tags from various sources...moreGood morning. My situation is… I’m using the trial version of Groov View Server for Windows on a PC currently. I have a lot of trends that are all working nicely reading PLC tags from various sources (Coming from Node-Red EthernetIP Nodes). Currently I have to re-start the Groov Server and reopen Groov View every two hours as it’s a trial version. If I restart the server immediately upon timing out, then I retain my older data. If it sits for a bit before reopening, I lose my older data. My ques...... <less Sensors that can tap into (so we can monitor and/or manipulate) badge access to one of our more sophisticated machine shop devices, like a laser cutter Forum - Published: We’re starting our Industry 4.0 transformation with the groov RIO (& eventually EPIC) product line. We’re looking for sensors that can tap into (so we can monitor and/or manipulate) badge access to one...moreWe’re starting our Industry 4.0 transformation with the groov RIO (& eventually EPIC) product line. We’re looking for sensors that can tap into (so we can monitor and/or manipulate) badge access to one of our more sophisticated machine shop devices, like a laser cutter. We went to ensure that the technician is qualified to operate the equipment. Any thoughts or suggestions?... <less RIO Device Scan unavailable? Forum - Published: Hello everyone, Trying to play with getting this RIO (MM1001-10) going with Codesys. I have successfully connected to it and gone online, however I cannot seem to scan the device for its I/O? Do I...moreHello everyone, Trying to play with getting this RIO (MM1001-10) going with Codesys. I have successfully connected to it and gone online, however I cannot seem to scan the device for its I/O? Do I need to set up each I/O channel in Groov manage first or am I missing something? Thanks in advance!... <less Read/Write I/O using commands to read/write enter I/O unit all at once Forum - Published: This is mainly a question about OptoControl, but as we move our hardware to groov, we are looking at ways to streamline our process. We’ve recently had a lot of issues (I/O units becoming disabled and...moreThis is mainly a question about OptoControl, but as we move our hardware to groov, we are looking at ways to streamline our process. We’ve recently had a lot of issues (I/O units becoming disabled and taking to long to be able to get them communicating again is the primary issue) communicating over serial cables on our LCM4 controllers so we’ve changed how we read/write to the I/O using the the following commands: MoveMixedIoUnitToTable MoveTableToMixedIoUnit MoveAnalogIoUnitToTable MoveTableToA...... <less Node-red energy meter rs485 modbus connection Forum - Published: Hello there, i have some problems with node-re modbus connection via rs485. i have conencted raspberry to Yada dcm6636 energy meter via rs485 port. The port open and communicate each other but in node...moreHello there, i have some problems with node-re modbus connection via rs485. i have conencted raspberry to Yada dcm6636 energy meter via rs485 port. The port open and communicate each other but in node-red no values come and it give time out error. is there know this problem’s solution anyone... <less Updating node-red project API Forum - Published: Hello! I’m working on setting up a CI pipeline for our node-red project and and I would like to automate the deployment to target. I thought maybe I could use the node-red admin API. More specifically...moreHello! I’m working on setting up a CI pipeline for our node-red project and and I would like to automate the deployment to target. I thought maybe I could use the node-red admin API. More specifically the POST /flows. However, when I try to use the API all I get is this: 301 Moved Permanently 301 Moved Permanently nginx/1.20.1 Is the node-red admin API not available on the groov EPIC? Are th...... <less I want to 32 crc and 30 crc and 16 crc with my own polynomial Forum - Published: I want to 32 crc and 30 crc and 16 crc with my own polynomial ,how can I implement this using opto scripting? please reply...I want to 32 crc and 30 crc and 16 crc with my own polynomial ,how can I implement this using opto scripting? please reply... <less EtherNet/IP Configurator for Groov? Forum - Published: I’ve been experimenting this week with the EtherNet/IP Configurator for SNAP PAC hardware. Is it possible to configure similar communication for I/O attached directly to a Groov EPIC-PR1?...I’ve been experimenting this week with the EtherNet/IP Configurator for SNAP PAC hardware. Is it possible to configure similar communication for I/O attached directly to a Groov EPIC-PR1?... <less Understanding high-density channel data for streaming via UDP Forum - Published: Hello, I am trying to understand how to interrupt the high-density channel data located in the OPTOMMP starting at address FFFF F100 0300. According to the structure on page 155 of the manual, this...moreHello, I am trying to understand how to interrupt the high-density channel data located in the OPTOMMP starting at address FFFF F100 0300. According to the structure on page 155 of the manual, this section should have the analog channels value in engineering units and the feature data for digital channels. image898×508 86.9 KB For now, I am trying to read the state of a digital output from a GRV-ODCI-12 card located in slot 0. The controller is a GRV-EPIC-PR1. From looking at the Generic MMP usi...... <less A problem in TCP/IP communication Forum - Published: A R1 controller and 10 temperature and humidity modules communicate through Ethernet. The control strategy in R1 uses an Ethernet communication handle to connect different temperature and humidity...moreA R1 controller and 10 temperature and humidity modules communicate through Ethernet. The control strategy in R1 uses an Ethernet communication handle to connect different temperature and humidity meters by changing the parameters of the communication handle. The R1 controller is the client of TCP communication. To test the effectiveness of TCP communication, I set the polling interval to 100ms, so there is no need for such fast polling during normal use. R1 has been running normally for several...... <less Issue in Opto 22 Groov EPIC PR2 Forum - Published: We are facing critical issues in our current setup involving OPTO 22 GROOV EPIC PR2 PLC and the Ignition Full V8.17 system. Our system configuration includes- OPTO 22 PLC: First Ethernet port- Serum...moreWe are facing critical issues in our current setup involving OPTO 22 GROOV EPIC PR2 PLC and the Ignition Full V8.17 system. Our system configuration includes- OPTO 22 PLC: First Ethernet port- Serum Corporate IP & Second Ethernet port- Local IP of Siemens PLC network. Implemented Data store-and-forward within the OPTO 22 PLC. Established communication between Ignition and 6 nos of Siemens PLCs using OPC devices within the OPTO 22. Integration of 6 databases communication with SQL 2019 in...... <less « PreviousPage 4 of 128Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Snap-Pac-R1 and LabVIEW interface Forum - Published: Hey everyone. I am trying to integrate OPTO22 into a previous LabVIEW vi. Does anyone have some examples or previously written LabVIEW vi’s that I can tweak to interface with my current project? I will...moreHey everyone. I am trying to integrate OPTO22 into a previous LabVIEW vi. Does anyone have some examples or previously written LabVIEW vi’s that I can tweak to interface with my current project? I will need to connect over ethernet and cannot use SNMP. It will need to be another communication format. Any help would be greatly appreciate as I am new to both LabVIEW and OPTO22 interface. Kevin... <less Opto Epic I/O points collected in a data-logger to csv file Forum - Published: I’m trying to build a simple data logger collecting I/O points (mostly just analog values), from the Opto Epic (we have PAC Controller also. Basically need a timestamp, roughly 10 analog points collected...moreI’m trying to build a simple data logger collecting I/O points (mostly just analog values), from the Opto Epic (we have PAC Controller also. Basically need a timestamp, roughly 10 analog points collected every 5 seconds, put into one CSV file (each day would be a new file name based on date: 2024-01-23) and within the csv file it would have a column for the timestamp, value 1, value 2, value 3…etc. Much appreciated.... <less Deleting Unused Images In Groov View Forum - Published: Hey Folks. So, I have been creating and adding images to my Groov View project. Its looking good! However, I now have some images I’m not using. I’d like to find the folder these images I import in are...moreHey Folks. So, I have been creating and adding images to my Groov View project. Its looking good! However, I now have some images I’m not using. I’d like to find the folder these images I import in are stored and delete them. Any idea where this folder would be? Thank you.... <less How to use the GRV-IDCIS-12 to measure RPMS Forum - Published: Hello. I am having difficulties trying to program this module to measure RPMS. I am using a proximity sensor that is being toggled by a metal screw on a plastic rotating shaft. This module doesn’t have...moreHello. I am having difficulties trying to program this module to measure RPMS. I am using a proximity sensor that is being toggled by a metal screw on a plastic rotating shaft. This module doesn’t have the features to set so I am trying to get around that for the time being. I am trying to have the screw start a count-up timer that keeps restarting when it sees it again. I want to input that value from the count-up timer into a formula to output value. I am not much of a programmer at all so any...... <less Groov View Drawings and Things Forum - Published: Good afternoon. I’m still using the Trial Version of Groov View. I’m trying to build an Overview of our Facilities to illustrate machine state and data. I’m wondering if there is more drawing tools in...moreGood afternoon. I’m still using the Trial Version of Groov View. I’m trying to build an Overview of our Facilities to illustrate machine state and data. I’m wondering if there is more drawing tools in the full version of Groov View. I find I’m very limited in drawing simple objects. I can import images, but I don’t have an option to draw for example a line or a line that is on a diagonal. I don’t really see an option to draw anything. I can place a Rectangle or an Oval. That is about it. I’m gue...... <less goovView Trends Float variable too long Forum - Published: I took the EPIC class last year, August class, I asked how to truncate float variables in groovView trend graphs. Terry said he had a solution in your forums. I couldn’t find it. Please give me...moreI took the EPIC class last year, August class, I asked how to truncate float variables in groovView trend graphs. Terry said he had a solution in your forums. I couldn’t find it. Please give me directions to shorten the decimal places on float variables when using a trend in groovView. 15 decimal places is too much, not just for groovView trends, but also when I send an event as a text it makes it difficult to see on the phone screen. I’m using EPIC PR1 with Firmware 3.5 and PAC Project 10.5b ru...... <less Printer Interface via an EPIC Controller Forum - Published: Have an existing system using an EPIC controller (PACProject) with Groov View via the HDMI port that needs to print reports. The intent is to try to do this without adding a PC to the system. I’ve done...moreHave an existing system using an EPIC controller (PACProject) with Groov View via the HDMI port that needs to print reports. The intent is to try to do this without adding a PC to the system. I’ve done ASCII to Serial (RS232) Printers years ago (via PACProject and an PAC-R) BUT serial printers are not as common today (most are for labels or receipts). Is there a way (or has anybody already done this) via Node-Red, PACControl, shell access, etc. that we can send our Text Files to a standard Ether...... <less Question On Trending in Groov View Forum - Published: Good morning. My situation is… I’m using the trial version of Groov View Server for Windows on a PC currently. I have a lot of trends that are all working nicely reading PLC tags from various sources...moreGood morning. My situation is… I’m using the trial version of Groov View Server for Windows on a PC currently. I have a lot of trends that are all working nicely reading PLC tags from various sources (Coming from Node-Red EthernetIP Nodes). Currently I have to re-start the Groov Server and reopen Groov View every two hours as it’s a trial version. If I restart the server immediately upon timing out, then I retain my older data. If it sits for a bit before reopening, I lose my older data. My ques...... <less Sensors that can tap into (so we can monitor and/or manipulate) badge access to one of our more sophisticated machine shop devices, like a laser cutter Forum - Published: We’re starting our Industry 4.0 transformation with the groov RIO (& eventually EPIC) product line. We’re looking for sensors that can tap into (so we can monitor and/or manipulate) badge access to one...moreWe’re starting our Industry 4.0 transformation with the groov RIO (& eventually EPIC) product line. We’re looking for sensors that can tap into (so we can monitor and/or manipulate) badge access to one of our more sophisticated machine shop devices, like a laser cutter. We went to ensure that the technician is qualified to operate the equipment. Any thoughts or suggestions?... <less RIO Device Scan unavailable? Forum - Published: Hello everyone, Trying to play with getting this RIO (MM1001-10) going with Codesys. I have successfully connected to it and gone online, however I cannot seem to scan the device for its I/O? Do I...moreHello everyone, Trying to play with getting this RIO (MM1001-10) going with Codesys. I have successfully connected to it and gone online, however I cannot seem to scan the device for its I/O? Do I need to set up each I/O channel in Groov manage first or am I missing something? Thanks in advance!... <less Read/Write I/O using commands to read/write enter I/O unit all at once Forum - Published: This is mainly a question about OptoControl, but as we move our hardware to groov, we are looking at ways to streamline our process. We’ve recently had a lot of issues (I/O units becoming disabled and...moreThis is mainly a question about OptoControl, but as we move our hardware to groov, we are looking at ways to streamline our process. We’ve recently had a lot of issues (I/O units becoming disabled and taking to long to be able to get them communicating again is the primary issue) communicating over serial cables on our LCM4 controllers so we’ve changed how we read/write to the I/O using the the following commands: MoveMixedIoUnitToTable MoveTableToMixedIoUnit MoveAnalogIoUnitToTable MoveTableToA...... <less Node-red energy meter rs485 modbus connection Forum - Published: Hello there, i have some problems with node-re modbus connection via rs485. i have conencted raspberry to Yada dcm6636 energy meter via rs485 port. The port open and communicate each other but in node...moreHello there, i have some problems with node-re modbus connection via rs485. i have conencted raspberry to Yada dcm6636 energy meter via rs485 port. The port open and communicate each other but in node-red no values come and it give time out error. is there know this problem’s solution anyone... <less Updating node-red project API Forum - Published: Hello! I’m working on setting up a CI pipeline for our node-red project and and I would like to automate the deployment to target. I thought maybe I could use the node-red admin API. More specifically...moreHello! I’m working on setting up a CI pipeline for our node-red project and and I would like to automate the deployment to target. I thought maybe I could use the node-red admin API. More specifically the POST /flows. However, when I try to use the API all I get is this: 301 Moved Permanently 301 Moved Permanently nginx/1.20.1 Is the node-red admin API not available on the groov EPIC? Are th...... <less I want to 32 crc and 30 crc and 16 crc with my own polynomial Forum - Published: I want to 32 crc and 30 crc and 16 crc with my own polynomial ,how can I implement this using opto scripting? please reply...I want to 32 crc and 30 crc and 16 crc with my own polynomial ,how can I implement this using opto scripting? please reply... <less EtherNet/IP Configurator for Groov? Forum - Published: I’ve been experimenting this week with the EtherNet/IP Configurator for SNAP PAC hardware. Is it possible to configure similar communication for I/O attached directly to a Groov EPIC-PR1?...I’ve been experimenting this week with the EtherNet/IP Configurator for SNAP PAC hardware. Is it possible to configure similar communication for I/O attached directly to a Groov EPIC-PR1?... <less Understanding high-density channel data for streaming via UDP Forum - Published: Hello, I am trying to understand how to interrupt the high-density channel data located in the OPTOMMP starting at address FFFF F100 0300. According to the structure on page 155 of the manual, this...moreHello, I am trying to understand how to interrupt the high-density channel data located in the OPTOMMP starting at address FFFF F100 0300. According to the structure on page 155 of the manual, this section should have the analog channels value in engineering units and the feature data for digital channels. image898×508 86.9 KB For now, I am trying to read the state of a digital output from a GRV-ODCI-12 card located in slot 0. The controller is a GRV-EPIC-PR1. From looking at the Generic MMP usi...... <less A problem in TCP/IP communication Forum - Published: A R1 controller and 10 temperature and humidity modules communicate through Ethernet. The control strategy in R1 uses an Ethernet communication handle to connect different temperature and humidity...moreA R1 controller and 10 temperature and humidity modules communicate through Ethernet. The control strategy in R1 uses an Ethernet communication handle to connect different temperature and humidity meters by changing the parameters of the communication handle. The R1 controller is the client of TCP communication. To test the effectiveness of TCP communication, I set the polling interval to 100ms, so there is no need for such fast polling during normal use. R1 has been running normally for several...... <less Issue in Opto 22 Groov EPIC PR2 Forum - Published: We are facing critical issues in our current setup involving OPTO 22 GROOV EPIC PR2 PLC and the Ignition Full V8.17 system. Our system configuration includes- OPTO 22 PLC: First Ethernet port- Serum...moreWe are facing critical issues in our current setup involving OPTO 22 GROOV EPIC PR2 PLC and the Ignition Full V8.17 system. Our system configuration includes- OPTO 22 PLC: First Ethernet port- Serum Corporate IP & Second Ethernet port- Local IP of Siemens PLC network. Implemented Data store-and-forward within the OPTO 22 PLC. Established communication between Ignition and 6 nos of Siemens PLCs using OPC devices within the OPTO 22. Integration of 6 databases communication with SQL 2019 in...... <less « PreviousPage 4 of 128Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Opto Epic I/O points collected in a data-logger to csv file Forum - Published: I’m trying to build a simple data logger collecting I/O points (mostly just analog values), from the Opto Epic (we have PAC Controller also. Basically need a timestamp, roughly 10 analog points collected...moreI’m trying to build a simple data logger collecting I/O points (mostly just analog values), from the Opto Epic (we have PAC Controller also. Basically need a timestamp, roughly 10 analog points collected every 5 seconds, put into one CSV file (each day would be a new file name based on date: 2024-01-23) and within the csv file it would have a column for the timestamp, value 1, value 2, value 3…etc. Much appreciated.... <less Deleting Unused Images In Groov View Forum - Published: Hey Folks. So, I have been creating and adding images to my Groov View project. Its looking good! However, I now have some images I’m not using. I’d like to find the folder these images I import in are...moreHey Folks. So, I have been creating and adding images to my Groov View project. Its looking good! However, I now have some images I’m not using. I’d like to find the folder these images I import in are stored and delete them. Any idea where this folder would be? Thank you.... <less How to use the GRV-IDCIS-12 to measure RPMS Forum - Published: Hello. I am having difficulties trying to program this module to measure RPMS. I am using a proximity sensor that is being toggled by a metal screw on a plastic rotating shaft. This module doesn’t have...moreHello. I am having difficulties trying to program this module to measure RPMS. I am using a proximity sensor that is being toggled by a metal screw on a plastic rotating shaft. This module doesn’t have the features to set so I am trying to get around that for the time being. I am trying to have the screw start a count-up timer that keeps restarting when it sees it again. I want to input that value from the count-up timer into a formula to output value. I am not much of a programmer at all so any...... <less Groov View Drawings and Things Forum - Published: Good afternoon. I’m still using the Trial Version of Groov View. I’m trying to build an Overview of our Facilities to illustrate machine state and data. I’m wondering if there is more drawing tools in...moreGood afternoon. I’m still using the Trial Version of Groov View. I’m trying to build an Overview of our Facilities to illustrate machine state and data. I’m wondering if there is more drawing tools in the full version of Groov View. I find I’m very limited in drawing simple objects. I can import images, but I don’t have an option to draw for example a line or a line that is on a diagonal. I don’t really see an option to draw anything. I can place a Rectangle or an Oval. That is about it. I’m gue...... <less goovView Trends Float variable too long Forum - Published: I took the EPIC class last year, August class, I asked how to truncate float variables in groovView trend graphs. Terry said he had a solution in your forums. I couldn’t find it. Please give me...moreI took the EPIC class last year, August class, I asked how to truncate float variables in groovView trend graphs. Terry said he had a solution in your forums. I couldn’t find it. Please give me directions to shorten the decimal places on float variables when using a trend in groovView. 15 decimal places is too much, not just for groovView trends, but also when I send an event as a text it makes it difficult to see on the phone screen. I’m using EPIC PR1 with Firmware 3.5 and PAC Project 10.5b ru...... <less Printer Interface via an EPIC Controller Forum - Published: Have an existing system using an EPIC controller (PACProject) with Groov View via the HDMI port that needs to print reports. The intent is to try to do this without adding a PC to the system. I’ve done...moreHave an existing system using an EPIC controller (PACProject) with Groov View via the HDMI port that needs to print reports. The intent is to try to do this without adding a PC to the system. I’ve done ASCII to Serial (RS232) Printers years ago (via PACProject and an PAC-R) BUT serial printers are not as common today (most are for labels or receipts). Is there a way (or has anybody already done this) via Node-Red, PACControl, shell access, etc. that we can send our Text Files to a standard Ether...... <less Question On Trending in Groov View Forum - Published: Good morning. My situation is… I’m using the trial version of Groov View Server for Windows on a PC currently. I have a lot of trends that are all working nicely reading PLC tags from various sources...moreGood morning. My situation is… I’m using the trial version of Groov View Server for Windows on a PC currently. I have a lot of trends that are all working nicely reading PLC tags from various sources (Coming from Node-Red EthernetIP Nodes). Currently I have to re-start the Groov Server and reopen Groov View every two hours as it’s a trial version. If I restart the server immediately upon timing out, then I retain my older data. If it sits for a bit before reopening, I lose my older data. My ques...... <less Sensors that can tap into (so we can monitor and/or manipulate) badge access to one of our more sophisticated machine shop devices, like a laser cutter Forum - Published: We’re starting our Industry 4.0 transformation with the groov RIO (& eventually EPIC) product line. We’re looking for sensors that can tap into (so we can monitor and/or manipulate) badge access to one...moreWe’re starting our Industry 4.0 transformation with the groov RIO (& eventually EPIC) product line. We’re looking for sensors that can tap into (so we can monitor and/or manipulate) badge access to one of our more sophisticated machine shop devices, like a laser cutter. We went to ensure that the technician is qualified to operate the equipment. Any thoughts or suggestions?... <less RIO Device Scan unavailable? Forum - Published: Hello everyone, Trying to play with getting this RIO (MM1001-10) going with Codesys. I have successfully connected to it and gone online, however I cannot seem to scan the device for its I/O? Do I...moreHello everyone, Trying to play with getting this RIO (MM1001-10) going with Codesys. I have successfully connected to it and gone online, however I cannot seem to scan the device for its I/O? Do I need to set up each I/O channel in Groov manage first or am I missing something? Thanks in advance!... <less Read/Write I/O using commands to read/write enter I/O unit all at once Forum - Published: This is mainly a question about OptoControl, but as we move our hardware to groov, we are looking at ways to streamline our process. We’ve recently had a lot of issues (I/O units becoming disabled and...moreThis is mainly a question about OptoControl, but as we move our hardware to groov, we are looking at ways to streamline our process. We’ve recently had a lot of issues (I/O units becoming disabled and taking to long to be able to get them communicating again is the primary issue) communicating over serial cables on our LCM4 controllers so we’ve changed how we read/write to the I/O using the the following commands: MoveMixedIoUnitToTable MoveTableToMixedIoUnit MoveAnalogIoUnitToTable MoveTableToA...... <less Node-red energy meter rs485 modbus connection Forum - Published: Hello there, i have some problems with node-re modbus connection via rs485. i have conencted raspberry to Yada dcm6636 energy meter via rs485 port. The port open and communicate each other but in node...moreHello there, i have some problems with node-re modbus connection via rs485. i have conencted raspberry to Yada dcm6636 energy meter via rs485 port. The port open and communicate each other but in node-red no values come and it give time out error. is there know this problem’s solution anyone... <less Updating node-red project API Forum - Published: Hello! I’m working on setting up a CI pipeline for our node-red project and and I would like to automate the deployment to target. I thought maybe I could use the node-red admin API. More specifically...moreHello! I’m working on setting up a CI pipeline for our node-red project and and I would like to automate the deployment to target. I thought maybe I could use the node-red admin API. More specifically the POST /flows. However, when I try to use the API all I get is this: 301 Moved Permanently 301 Moved Permanently nginx/1.20.1 Is the node-red admin API not available on the groov EPIC? Are th...... <less I want to 32 crc and 30 crc and 16 crc with my own polynomial Forum - Published: I want to 32 crc and 30 crc and 16 crc with my own polynomial ,how can I implement this using opto scripting? please reply...I want to 32 crc and 30 crc and 16 crc with my own polynomial ,how can I implement this using opto scripting? please reply... <less EtherNet/IP Configurator for Groov? Forum - Published: I’ve been experimenting this week with the EtherNet/IP Configurator for SNAP PAC hardware. Is it possible to configure similar communication for I/O attached directly to a Groov EPIC-PR1?...I’ve been experimenting this week with the EtherNet/IP Configurator for SNAP PAC hardware. Is it possible to configure similar communication for I/O attached directly to a Groov EPIC-PR1?... <less Understanding high-density channel data for streaming via UDP Forum - Published: Hello, I am trying to understand how to interrupt the high-density channel data located in the OPTOMMP starting at address FFFF F100 0300. According to the structure on page 155 of the manual, this...moreHello, I am trying to understand how to interrupt the high-density channel data located in the OPTOMMP starting at address FFFF F100 0300. According to the structure on page 155 of the manual, this section should have the analog channels value in engineering units and the feature data for digital channels. image898×508 86.9 KB For now, I am trying to read the state of a digital output from a GRV-ODCI-12 card located in slot 0. The controller is a GRV-EPIC-PR1. From looking at the Generic MMP usi...... <less A problem in TCP/IP communication Forum - Published: A R1 controller and 10 temperature and humidity modules communicate through Ethernet. The control strategy in R1 uses an Ethernet communication handle to connect different temperature and humidity...moreA R1 controller and 10 temperature and humidity modules communicate through Ethernet. The control strategy in R1 uses an Ethernet communication handle to connect different temperature and humidity meters by changing the parameters of the communication handle. The R1 controller is the client of TCP communication. To test the effectiveness of TCP communication, I set the polling interval to 100ms, so there is no need for such fast polling during normal use. R1 has been running normally for several...... <less Issue in Opto 22 Groov EPIC PR2 Forum - Published: We are facing critical issues in our current setup involving OPTO 22 GROOV EPIC PR2 PLC and the Ignition Full V8.17 system. Our system configuration includes- OPTO 22 PLC: First Ethernet port- Serum...moreWe are facing critical issues in our current setup involving OPTO 22 GROOV EPIC PR2 PLC and the Ignition Full V8.17 system. Our system configuration includes- OPTO 22 PLC: First Ethernet port- Serum Corporate IP & Second Ethernet port- Local IP of Siemens PLC network. Implemented Data store-and-forward within the OPTO 22 PLC. Established communication between Ignition and 6 nos of Siemens PLCs using OPC devices within the OPTO 22. Integration of 6 databases communication with SQL 2019 in...... <less « PreviousPage 4 of 128Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Deleting Unused Images In Groov View Forum - Published: Hey Folks. So, I have been creating and adding images to my Groov View project. Its looking good! However, I now have some images I’m not using. I’d like to find the folder these images I import in are...moreHey Folks. So, I have been creating and adding images to my Groov View project. Its looking good! However, I now have some images I’m not using. I’d like to find the folder these images I import in are stored and delete them. Any idea where this folder would be? Thank you.... <less How to use the GRV-IDCIS-12 to measure RPMS Forum - Published: Hello. I am having difficulties trying to program this module to measure RPMS. I am using a proximity sensor that is being toggled by a metal screw on a plastic rotating shaft. This module doesn’t have...moreHello. I am having difficulties trying to program this module to measure RPMS. I am using a proximity sensor that is being toggled by a metal screw on a plastic rotating shaft. This module doesn’t have the features to set so I am trying to get around that for the time being. I am trying to have the screw start a count-up timer that keeps restarting when it sees it again. I want to input that value from the count-up timer into a formula to output value. I am not much of a programmer at all so any...... <less Groov View Drawings and Things Forum - Published: Good afternoon. I’m still using the Trial Version of Groov View. I’m trying to build an Overview of our Facilities to illustrate machine state and data. I’m wondering if there is more drawing tools in...moreGood afternoon. I’m still using the Trial Version of Groov View. I’m trying to build an Overview of our Facilities to illustrate machine state and data. I’m wondering if there is more drawing tools in the full version of Groov View. I find I’m very limited in drawing simple objects. I can import images, but I don’t have an option to draw for example a line or a line that is on a diagonal. I don’t really see an option to draw anything. I can place a Rectangle or an Oval. That is about it. I’m gue...... <less goovView Trends Float variable too long Forum - Published: I took the EPIC class last year, August class, I asked how to truncate float variables in groovView trend graphs. Terry said he had a solution in your forums. I couldn’t find it. Please give me...moreI took the EPIC class last year, August class, I asked how to truncate float variables in groovView trend graphs. Terry said he had a solution in your forums. I couldn’t find it. Please give me directions to shorten the decimal places on float variables when using a trend in groovView. 15 decimal places is too much, not just for groovView trends, but also when I send an event as a text it makes it difficult to see on the phone screen. I’m using EPIC PR1 with Firmware 3.5 and PAC Project 10.5b ru...... <less Printer Interface via an EPIC Controller Forum - Published: Have an existing system using an EPIC controller (PACProject) with Groov View via the HDMI port that needs to print reports. The intent is to try to do this without adding a PC to the system. I’ve done...moreHave an existing system using an EPIC controller (PACProject) with Groov View via the HDMI port that needs to print reports. The intent is to try to do this without adding a PC to the system. I’ve done ASCII to Serial (RS232) Printers years ago (via PACProject and an PAC-R) BUT serial printers are not as common today (most are for labels or receipts). Is there a way (or has anybody already done this) via Node-Red, PACControl, shell access, etc. that we can send our Text Files to a standard Ether...... <less Question On Trending in Groov View Forum - Published: Good morning. My situation is… I’m using the trial version of Groov View Server for Windows on a PC currently. I have a lot of trends that are all working nicely reading PLC tags from various sources...moreGood morning. My situation is… I’m using the trial version of Groov View Server for Windows on a PC currently. I have a lot of trends that are all working nicely reading PLC tags from various sources (Coming from Node-Red EthernetIP Nodes). Currently I have to re-start the Groov Server and reopen Groov View every two hours as it’s a trial version. If I restart the server immediately upon timing out, then I retain my older data. If it sits for a bit before reopening, I lose my older data. My ques...... <less Sensors that can tap into (so we can monitor and/or manipulate) badge access to one of our more sophisticated machine shop devices, like a laser cutter Forum - Published: We’re starting our Industry 4.0 transformation with the groov RIO (& eventually EPIC) product line. We’re looking for sensors that can tap into (so we can monitor and/or manipulate) badge access to one...moreWe’re starting our Industry 4.0 transformation with the groov RIO (& eventually EPIC) product line. We’re looking for sensors that can tap into (so we can monitor and/or manipulate) badge access to one of our more sophisticated machine shop devices, like a laser cutter. We went to ensure that the technician is qualified to operate the equipment. Any thoughts or suggestions?... <less RIO Device Scan unavailable? Forum - Published: Hello everyone, Trying to play with getting this RIO (MM1001-10) going with Codesys. I have successfully connected to it and gone online, however I cannot seem to scan the device for its I/O? Do I...moreHello everyone, Trying to play with getting this RIO (MM1001-10) going with Codesys. I have successfully connected to it and gone online, however I cannot seem to scan the device for its I/O? Do I need to set up each I/O channel in Groov manage first or am I missing something? Thanks in advance!... <less Read/Write I/O using commands to read/write enter I/O unit all at once Forum - Published: This is mainly a question about OptoControl, but as we move our hardware to groov, we are looking at ways to streamline our process. We’ve recently had a lot of issues (I/O units becoming disabled and...moreThis is mainly a question about OptoControl, but as we move our hardware to groov, we are looking at ways to streamline our process. We’ve recently had a lot of issues (I/O units becoming disabled and taking to long to be able to get them communicating again is the primary issue) communicating over serial cables on our LCM4 controllers so we’ve changed how we read/write to the I/O using the the following commands: MoveMixedIoUnitToTable MoveTableToMixedIoUnit MoveAnalogIoUnitToTable MoveTableToA...... <less Node-red energy meter rs485 modbus connection Forum - Published: Hello there, i have some problems with node-re modbus connection via rs485. i have conencted raspberry to Yada dcm6636 energy meter via rs485 port. The port open and communicate each other but in node...moreHello there, i have some problems with node-re modbus connection via rs485. i have conencted raspberry to Yada dcm6636 energy meter via rs485 port. The port open and communicate each other but in node-red no values come and it give time out error. is there know this problem’s solution anyone... <less Updating node-red project API Forum - Published: Hello! I’m working on setting up a CI pipeline for our node-red project and and I would like to automate the deployment to target. I thought maybe I could use the node-red admin API. More specifically...moreHello! I’m working on setting up a CI pipeline for our node-red project and and I would like to automate the deployment to target. I thought maybe I could use the node-red admin API. More specifically the POST /flows. However, when I try to use the API all I get is this: 301 Moved Permanently 301 Moved Permanently nginx/1.20.1 Is the node-red admin API not available on the groov EPIC? Are th...... <less I want to 32 crc and 30 crc and 16 crc with my own polynomial Forum - Published: I want to 32 crc and 30 crc and 16 crc with my own polynomial ,how can I implement this using opto scripting? please reply...I want to 32 crc and 30 crc and 16 crc with my own polynomial ,how can I implement this using opto scripting? please reply... <less EtherNet/IP Configurator for Groov? Forum - Published: I’ve been experimenting this week with the EtherNet/IP Configurator for SNAP PAC hardware. Is it possible to configure similar communication for I/O attached directly to a Groov EPIC-PR1?...I’ve been experimenting this week with the EtherNet/IP Configurator for SNAP PAC hardware. Is it possible to configure similar communication for I/O attached directly to a Groov EPIC-PR1?... <less Understanding high-density channel data for streaming via UDP Forum - Published: Hello, I am trying to understand how to interrupt the high-density channel data located in the OPTOMMP starting at address FFFF F100 0300. According to the structure on page 155 of the manual, this...moreHello, I am trying to understand how to interrupt the high-density channel data located in the OPTOMMP starting at address FFFF F100 0300. According to the structure on page 155 of the manual, this section should have the analog channels value in engineering units and the feature data for digital channels. image898×508 86.9 KB For now, I am trying to read the state of a digital output from a GRV-ODCI-12 card located in slot 0. The controller is a GRV-EPIC-PR1. From looking at the Generic MMP usi...... <less A problem in TCP/IP communication Forum - Published: A R1 controller and 10 temperature and humidity modules communicate through Ethernet. The control strategy in R1 uses an Ethernet communication handle to connect different temperature and humidity...moreA R1 controller and 10 temperature and humidity modules communicate through Ethernet. The control strategy in R1 uses an Ethernet communication handle to connect different temperature and humidity meters by changing the parameters of the communication handle. The R1 controller is the client of TCP communication. To test the effectiveness of TCP communication, I set the polling interval to 100ms, so there is no need for such fast polling during normal use. R1 has been running normally for several...... <less Issue in Opto 22 Groov EPIC PR2 Forum - Published: We are facing critical issues in our current setup involving OPTO 22 GROOV EPIC PR2 PLC and the Ignition Full V8.17 system. Our system configuration includes- OPTO 22 PLC: First Ethernet port- Serum...moreWe are facing critical issues in our current setup involving OPTO 22 GROOV EPIC PR2 PLC and the Ignition Full V8.17 system. Our system configuration includes- OPTO 22 PLC: First Ethernet port- Serum Corporate IP & Second Ethernet port- Local IP of Siemens PLC network. Implemented Data store-and-forward within the OPTO 22 PLC. Established communication between Ignition and 6 nos of Siemens PLCs using OPC devices within the OPTO 22. Integration of 6 databases communication with SQL 2019 in...... <less « PreviousPage 4 of 128Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
How to use the GRV-IDCIS-12 to measure RPMS Forum - Published: Hello. I am having difficulties trying to program this module to measure RPMS. I am using a proximity sensor that is being toggled by a metal screw on a plastic rotating shaft. This module doesn’t have...moreHello. I am having difficulties trying to program this module to measure RPMS. I am using a proximity sensor that is being toggled by a metal screw on a plastic rotating shaft. This module doesn’t have the features to set so I am trying to get around that for the time being. I am trying to have the screw start a count-up timer that keeps restarting when it sees it again. I want to input that value from the count-up timer into a formula to output value. I am not much of a programmer at all so any...... <less Groov View Drawings and Things Forum - Published: Good afternoon. I’m still using the Trial Version of Groov View. I’m trying to build an Overview of our Facilities to illustrate machine state and data. I’m wondering if there is more drawing tools in...moreGood afternoon. I’m still using the Trial Version of Groov View. I’m trying to build an Overview of our Facilities to illustrate machine state and data. I’m wondering if there is more drawing tools in the full version of Groov View. I find I’m very limited in drawing simple objects. I can import images, but I don’t have an option to draw for example a line or a line that is on a diagonal. I don’t really see an option to draw anything. I can place a Rectangle or an Oval. That is about it. I’m gue...... <less goovView Trends Float variable too long Forum - Published: I took the EPIC class last year, August class, I asked how to truncate float variables in groovView trend graphs. Terry said he had a solution in your forums. I couldn’t find it. Please give me...moreI took the EPIC class last year, August class, I asked how to truncate float variables in groovView trend graphs. Terry said he had a solution in your forums. I couldn’t find it. Please give me directions to shorten the decimal places on float variables when using a trend in groovView. 15 decimal places is too much, not just for groovView trends, but also when I send an event as a text it makes it difficult to see on the phone screen. I’m using EPIC PR1 with Firmware 3.5 and PAC Project 10.5b ru...... <less Printer Interface via an EPIC Controller Forum - Published: Have an existing system using an EPIC controller (PACProject) with Groov View via the HDMI port that needs to print reports. The intent is to try to do this without adding a PC to the system. I’ve done...moreHave an existing system using an EPIC controller (PACProject) with Groov View via the HDMI port that needs to print reports. The intent is to try to do this without adding a PC to the system. I’ve done ASCII to Serial (RS232) Printers years ago (via PACProject and an PAC-R) BUT serial printers are not as common today (most are for labels or receipts). Is there a way (or has anybody already done this) via Node-Red, PACControl, shell access, etc. that we can send our Text Files to a standard Ether...... <less Question On Trending in Groov View Forum - Published: Good morning. My situation is… I’m using the trial version of Groov View Server for Windows on a PC currently. I have a lot of trends that are all working nicely reading PLC tags from various sources...moreGood morning. My situation is… I’m using the trial version of Groov View Server for Windows on a PC currently. I have a lot of trends that are all working nicely reading PLC tags from various sources (Coming from Node-Red EthernetIP Nodes). Currently I have to re-start the Groov Server and reopen Groov View every two hours as it’s a trial version. If I restart the server immediately upon timing out, then I retain my older data. If it sits for a bit before reopening, I lose my older data. My ques...... <less Sensors that can tap into (so we can monitor and/or manipulate) badge access to one of our more sophisticated machine shop devices, like a laser cutter Forum - Published: We’re starting our Industry 4.0 transformation with the groov RIO (& eventually EPIC) product line. We’re looking for sensors that can tap into (so we can monitor and/or manipulate) badge access to one...moreWe’re starting our Industry 4.0 transformation with the groov RIO (& eventually EPIC) product line. We’re looking for sensors that can tap into (so we can monitor and/or manipulate) badge access to one of our more sophisticated machine shop devices, like a laser cutter. We went to ensure that the technician is qualified to operate the equipment. Any thoughts or suggestions?... <less RIO Device Scan unavailable? Forum - Published: Hello everyone, Trying to play with getting this RIO (MM1001-10) going with Codesys. I have successfully connected to it and gone online, however I cannot seem to scan the device for its I/O? Do I...moreHello everyone, Trying to play with getting this RIO (MM1001-10) going with Codesys. I have successfully connected to it and gone online, however I cannot seem to scan the device for its I/O? Do I need to set up each I/O channel in Groov manage first or am I missing something? Thanks in advance!... <less Read/Write I/O using commands to read/write enter I/O unit all at once Forum - Published: This is mainly a question about OptoControl, but as we move our hardware to groov, we are looking at ways to streamline our process. We’ve recently had a lot of issues (I/O units becoming disabled and...moreThis is mainly a question about OptoControl, but as we move our hardware to groov, we are looking at ways to streamline our process. We’ve recently had a lot of issues (I/O units becoming disabled and taking to long to be able to get them communicating again is the primary issue) communicating over serial cables on our LCM4 controllers so we’ve changed how we read/write to the I/O using the the following commands: MoveMixedIoUnitToTable MoveTableToMixedIoUnit MoveAnalogIoUnitToTable MoveTableToA...... <less Node-red energy meter rs485 modbus connection Forum - Published: Hello there, i have some problems with node-re modbus connection via rs485. i have conencted raspberry to Yada dcm6636 energy meter via rs485 port. The port open and communicate each other but in node...moreHello there, i have some problems with node-re modbus connection via rs485. i have conencted raspberry to Yada dcm6636 energy meter via rs485 port. The port open and communicate each other but in node-red no values come and it give time out error. is there know this problem’s solution anyone... <less Updating node-red project API Forum - Published: Hello! I’m working on setting up a CI pipeline for our node-red project and and I would like to automate the deployment to target. I thought maybe I could use the node-red admin API. More specifically...moreHello! I’m working on setting up a CI pipeline for our node-red project and and I would like to automate the deployment to target. I thought maybe I could use the node-red admin API. More specifically the POST /flows. However, when I try to use the API all I get is this: 301 Moved Permanently 301 Moved Permanently nginx/1.20.1 Is the node-red admin API not available on the groov EPIC? Are th...... <less I want to 32 crc and 30 crc and 16 crc with my own polynomial Forum - Published: I want to 32 crc and 30 crc and 16 crc with my own polynomial ,how can I implement this using opto scripting? please reply...I want to 32 crc and 30 crc and 16 crc with my own polynomial ,how can I implement this using opto scripting? please reply... <less EtherNet/IP Configurator for Groov? Forum - Published: I’ve been experimenting this week with the EtherNet/IP Configurator for SNAP PAC hardware. Is it possible to configure similar communication for I/O attached directly to a Groov EPIC-PR1?...I’ve been experimenting this week with the EtherNet/IP Configurator for SNAP PAC hardware. Is it possible to configure similar communication for I/O attached directly to a Groov EPIC-PR1?... <less Understanding high-density channel data for streaming via UDP Forum - Published: Hello, I am trying to understand how to interrupt the high-density channel data located in the OPTOMMP starting at address FFFF F100 0300. According to the structure on page 155 of the manual, this...moreHello, I am trying to understand how to interrupt the high-density channel data located in the OPTOMMP starting at address FFFF F100 0300. According to the structure on page 155 of the manual, this section should have the analog channels value in engineering units and the feature data for digital channels. image898×508 86.9 KB For now, I am trying to read the state of a digital output from a GRV-ODCI-12 card located in slot 0. The controller is a GRV-EPIC-PR1. From looking at the Generic MMP usi...... <less A problem in TCP/IP communication Forum - Published: A R1 controller and 10 temperature and humidity modules communicate through Ethernet. The control strategy in R1 uses an Ethernet communication handle to connect different temperature and humidity...moreA R1 controller and 10 temperature and humidity modules communicate through Ethernet. The control strategy in R1 uses an Ethernet communication handle to connect different temperature and humidity meters by changing the parameters of the communication handle. The R1 controller is the client of TCP communication. To test the effectiveness of TCP communication, I set the polling interval to 100ms, so there is no need for such fast polling during normal use. R1 has been running normally for several...... <less Issue in Opto 22 Groov EPIC PR2 Forum - Published: We are facing critical issues in our current setup involving OPTO 22 GROOV EPIC PR2 PLC and the Ignition Full V8.17 system. Our system configuration includes- OPTO 22 PLC: First Ethernet port- Serum...moreWe are facing critical issues in our current setup involving OPTO 22 GROOV EPIC PR2 PLC and the Ignition Full V8.17 system. Our system configuration includes- OPTO 22 PLC: First Ethernet port- Serum Corporate IP & Second Ethernet port- Local IP of Siemens PLC network. Implemented Data store-and-forward within the OPTO 22 PLC. Established communication between Ignition and 6 nos of Siemens PLCs using OPC devices within the OPTO 22. Integration of 6 databases communication with SQL 2019 in...... <less « PreviousPage 4 of 128Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Groov View Drawings and Things Forum - Published: Good afternoon. I’m still using the Trial Version of Groov View. I’m trying to build an Overview of our Facilities to illustrate machine state and data. I’m wondering if there is more drawing tools in...moreGood afternoon. I’m still using the Trial Version of Groov View. I’m trying to build an Overview of our Facilities to illustrate machine state and data. I’m wondering if there is more drawing tools in the full version of Groov View. I find I’m very limited in drawing simple objects. I can import images, but I don’t have an option to draw for example a line or a line that is on a diagonal. I don’t really see an option to draw anything. I can place a Rectangle or an Oval. That is about it. I’m gue...... <less goovView Trends Float variable too long Forum - Published: I took the EPIC class last year, August class, I asked how to truncate float variables in groovView trend graphs. Terry said he had a solution in your forums. I couldn’t find it. Please give me...moreI took the EPIC class last year, August class, I asked how to truncate float variables in groovView trend graphs. Terry said he had a solution in your forums. I couldn’t find it. Please give me directions to shorten the decimal places on float variables when using a trend in groovView. 15 decimal places is too much, not just for groovView trends, but also when I send an event as a text it makes it difficult to see on the phone screen. I’m using EPIC PR1 with Firmware 3.5 and PAC Project 10.5b ru...... <less Printer Interface via an EPIC Controller Forum - Published: Have an existing system using an EPIC controller (PACProject) with Groov View via the HDMI port that needs to print reports. The intent is to try to do this without adding a PC to the system. I’ve done...moreHave an existing system using an EPIC controller (PACProject) with Groov View via the HDMI port that needs to print reports. The intent is to try to do this without adding a PC to the system. I’ve done ASCII to Serial (RS232) Printers years ago (via PACProject and an PAC-R) BUT serial printers are not as common today (most are for labels or receipts). Is there a way (or has anybody already done this) via Node-Red, PACControl, shell access, etc. that we can send our Text Files to a standard Ether...... <less Question On Trending in Groov View Forum - Published: Good morning. My situation is… I’m using the trial version of Groov View Server for Windows on a PC currently. I have a lot of trends that are all working nicely reading PLC tags from various sources...moreGood morning. My situation is… I’m using the trial version of Groov View Server for Windows on a PC currently. I have a lot of trends that are all working nicely reading PLC tags from various sources (Coming from Node-Red EthernetIP Nodes). Currently I have to re-start the Groov Server and reopen Groov View every two hours as it’s a trial version. If I restart the server immediately upon timing out, then I retain my older data. If it sits for a bit before reopening, I lose my older data. My ques...... <less Sensors that can tap into (so we can monitor and/or manipulate) badge access to one of our more sophisticated machine shop devices, like a laser cutter Forum - Published: We’re starting our Industry 4.0 transformation with the groov RIO (& eventually EPIC) product line. We’re looking for sensors that can tap into (so we can monitor and/or manipulate) badge access to one...moreWe’re starting our Industry 4.0 transformation with the groov RIO (& eventually EPIC) product line. We’re looking for sensors that can tap into (so we can monitor and/or manipulate) badge access to one of our more sophisticated machine shop devices, like a laser cutter. We went to ensure that the technician is qualified to operate the equipment. Any thoughts or suggestions?... <less RIO Device Scan unavailable? Forum - Published: Hello everyone, Trying to play with getting this RIO (MM1001-10) going with Codesys. I have successfully connected to it and gone online, however I cannot seem to scan the device for its I/O? Do I...moreHello everyone, Trying to play with getting this RIO (MM1001-10) going with Codesys. I have successfully connected to it and gone online, however I cannot seem to scan the device for its I/O? Do I need to set up each I/O channel in Groov manage first or am I missing something? Thanks in advance!... <less Read/Write I/O using commands to read/write enter I/O unit all at once Forum - Published: This is mainly a question about OptoControl, but as we move our hardware to groov, we are looking at ways to streamline our process. We’ve recently had a lot of issues (I/O units becoming disabled and...moreThis is mainly a question about OptoControl, but as we move our hardware to groov, we are looking at ways to streamline our process. We’ve recently had a lot of issues (I/O units becoming disabled and taking to long to be able to get them communicating again is the primary issue) communicating over serial cables on our LCM4 controllers so we’ve changed how we read/write to the I/O using the the following commands: MoveMixedIoUnitToTable MoveTableToMixedIoUnit MoveAnalogIoUnitToTable MoveTableToA...... <less Node-red energy meter rs485 modbus connection Forum - Published: Hello there, i have some problems with node-re modbus connection via rs485. i have conencted raspberry to Yada dcm6636 energy meter via rs485 port. The port open and communicate each other but in node...moreHello there, i have some problems with node-re modbus connection via rs485. i have conencted raspberry to Yada dcm6636 energy meter via rs485 port. The port open and communicate each other but in node-red no values come and it give time out error. is there know this problem’s solution anyone... <less Updating node-red project API Forum - Published: Hello! I’m working on setting up a CI pipeline for our node-red project and and I would like to automate the deployment to target. I thought maybe I could use the node-red admin API. More specifically...moreHello! I’m working on setting up a CI pipeline for our node-red project and and I would like to automate the deployment to target. I thought maybe I could use the node-red admin API. More specifically the POST /flows. However, when I try to use the API all I get is this: 301 Moved Permanently 301 Moved Permanently nginx/1.20.1 Is the node-red admin API not available on the groov EPIC? Are th...... <less I want to 32 crc and 30 crc and 16 crc with my own polynomial Forum - Published: I want to 32 crc and 30 crc and 16 crc with my own polynomial ,how can I implement this using opto scripting? please reply...I want to 32 crc and 30 crc and 16 crc with my own polynomial ,how can I implement this using opto scripting? please reply... <less EtherNet/IP Configurator for Groov? Forum - Published: I’ve been experimenting this week with the EtherNet/IP Configurator for SNAP PAC hardware. Is it possible to configure similar communication for I/O attached directly to a Groov EPIC-PR1?...I’ve been experimenting this week with the EtherNet/IP Configurator for SNAP PAC hardware. Is it possible to configure similar communication for I/O attached directly to a Groov EPIC-PR1?... <less Understanding high-density channel data for streaming via UDP Forum - Published: Hello, I am trying to understand how to interrupt the high-density channel data located in the OPTOMMP starting at address FFFF F100 0300. According to the structure on page 155 of the manual, this...moreHello, I am trying to understand how to interrupt the high-density channel data located in the OPTOMMP starting at address FFFF F100 0300. According to the structure on page 155 of the manual, this section should have the analog channels value in engineering units and the feature data for digital channels. image898×508 86.9 KB For now, I am trying to read the state of a digital output from a GRV-ODCI-12 card located in slot 0. The controller is a GRV-EPIC-PR1. From looking at the Generic MMP usi...... <less A problem in TCP/IP communication Forum - Published: A R1 controller and 10 temperature and humidity modules communicate through Ethernet. The control strategy in R1 uses an Ethernet communication handle to connect different temperature and humidity...moreA R1 controller and 10 temperature and humidity modules communicate through Ethernet. The control strategy in R1 uses an Ethernet communication handle to connect different temperature and humidity meters by changing the parameters of the communication handle. The R1 controller is the client of TCP communication. To test the effectiveness of TCP communication, I set the polling interval to 100ms, so there is no need for such fast polling during normal use. R1 has been running normally for several...... <less Issue in Opto 22 Groov EPIC PR2 Forum - Published: We are facing critical issues in our current setup involving OPTO 22 GROOV EPIC PR2 PLC and the Ignition Full V8.17 system. Our system configuration includes- OPTO 22 PLC: First Ethernet port- Serum...moreWe are facing critical issues in our current setup involving OPTO 22 GROOV EPIC PR2 PLC and the Ignition Full V8.17 system. Our system configuration includes- OPTO 22 PLC: First Ethernet port- Serum Corporate IP & Second Ethernet port- Local IP of Siemens PLC network. Implemented Data store-and-forward within the OPTO 22 PLC. Established communication between Ignition and 6 nos of Siemens PLCs using OPC devices within the OPTO 22. Integration of 6 databases communication with SQL 2019 in...... <less « PreviousPage 4 of 128Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
goovView Trends Float variable too long Forum - Published: I took the EPIC class last year, August class, I asked how to truncate float variables in groovView trend graphs. Terry said he had a solution in your forums. I couldn’t find it. Please give me...moreI took the EPIC class last year, August class, I asked how to truncate float variables in groovView trend graphs. Terry said he had a solution in your forums. I couldn’t find it. Please give me directions to shorten the decimal places on float variables when using a trend in groovView. 15 decimal places is too much, not just for groovView trends, but also when I send an event as a text it makes it difficult to see on the phone screen. I’m using EPIC PR1 with Firmware 3.5 and PAC Project 10.5b ru...... <less Printer Interface via an EPIC Controller Forum - Published: Have an existing system using an EPIC controller (PACProject) with Groov View via the HDMI port that needs to print reports. The intent is to try to do this without adding a PC to the system. I’ve done...moreHave an existing system using an EPIC controller (PACProject) with Groov View via the HDMI port that needs to print reports. The intent is to try to do this without adding a PC to the system. I’ve done ASCII to Serial (RS232) Printers years ago (via PACProject and an PAC-R) BUT serial printers are not as common today (most are for labels or receipts). Is there a way (or has anybody already done this) via Node-Red, PACControl, shell access, etc. that we can send our Text Files to a standard Ether...... <less Question On Trending in Groov View Forum - Published: Good morning. My situation is… I’m using the trial version of Groov View Server for Windows on a PC currently. I have a lot of trends that are all working nicely reading PLC tags from various sources...moreGood morning. My situation is… I’m using the trial version of Groov View Server for Windows on a PC currently. I have a lot of trends that are all working nicely reading PLC tags from various sources (Coming from Node-Red EthernetIP Nodes). Currently I have to re-start the Groov Server and reopen Groov View every two hours as it’s a trial version. If I restart the server immediately upon timing out, then I retain my older data. If it sits for a bit before reopening, I lose my older data. My ques...... <less Sensors that can tap into (so we can monitor and/or manipulate) badge access to one of our more sophisticated machine shop devices, like a laser cutter Forum - Published: We’re starting our Industry 4.0 transformation with the groov RIO (& eventually EPIC) product line. We’re looking for sensors that can tap into (so we can monitor and/or manipulate) badge access to one...moreWe’re starting our Industry 4.0 transformation with the groov RIO (& eventually EPIC) product line. We’re looking for sensors that can tap into (so we can monitor and/or manipulate) badge access to one of our more sophisticated machine shop devices, like a laser cutter. We went to ensure that the technician is qualified to operate the equipment. Any thoughts or suggestions?... <less RIO Device Scan unavailable? Forum - Published: Hello everyone, Trying to play with getting this RIO (MM1001-10) going with Codesys. I have successfully connected to it and gone online, however I cannot seem to scan the device for its I/O? Do I...moreHello everyone, Trying to play with getting this RIO (MM1001-10) going with Codesys. I have successfully connected to it and gone online, however I cannot seem to scan the device for its I/O? Do I need to set up each I/O channel in Groov manage first or am I missing something? Thanks in advance!... <less Read/Write I/O using commands to read/write enter I/O unit all at once Forum - Published: This is mainly a question about OptoControl, but as we move our hardware to groov, we are looking at ways to streamline our process. We’ve recently had a lot of issues (I/O units becoming disabled and...moreThis is mainly a question about OptoControl, but as we move our hardware to groov, we are looking at ways to streamline our process. We’ve recently had a lot of issues (I/O units becoming disabled and taking to long to be able to get them communicating again is the primary issue) communicating over serial cables on our LCM4 controllers so we’ve changed how we read/write to the I/O using the the following commands: MoveMixedIoUnitToTable MoveTableToMixedIoUnit MoveAnalogIoUnitToTable MoveTableToA...... <less Node-red energy meter rs485 modbus connection Forum - Published: Hello there, i have some problems with node-re modbus connection via rs485. i have conencted raspberry to Yada dcm6636 energy meter via rs485 port. The port open and communicate each other but in node...moreHello there, i have some problems with node-re modbus connection via rs485. i have conencted raspberry to Yada dcm6636 energy meter via rs485 port. The port open and communicate each other but in node-red no values come and it give time out error. is there know this problem’s solution anyone... <less Updating node-red project API Forum - Published: Hello! I’m working on setting up a CI pipeline for our node-red project and and I would like to automate the deployment to target. I thought maybe I could use the node-red admin API. More specifically...moreHello! I’m working on setting up a CI pipeline for our node-red project and and I would like to automate the deployment to target. I thought maybe I could use the node-red admin API. More specifically the POST /flows. However, when I try to use the API all I get is this: 301 Moved Permanently 301 Moved Permanently nginx/1.20.1 Is the node-red admin API not available on the groov EPIC? Are th...... <less I want to 32 crc and 30 crc and 16 crc with my own polynomial Forum - Published: I want to 32 crc and 30 crc and 16 crc with my own polynomial ,how can I implement this using opto scripting? please reply...I want to 32 crc and 30 crc and 16 crc with my own polynomial ,how can I implement this using opto scripting? please reply... <less EtherNet/IP Configurator for Groov? Forum - Published: I’ve been experimenting this week with the EtherNet/IP Configurator for SNAP PAC hardware. Is it possible to configure similar communication for I/O attached directly to a Groov EPIC-PR1?...I’ve been experimenting this week with the EtherNet/IP Configurator for SNAP PAC hardware. Is it possible to configure similar communication for I/O attached directly to a Groov EPIC-PR1?... <less Understanding high-density channel data for streaming via UDP Forum - Published: Hello, I am trying to understand how to interrupt the high-density channel data located in the OPTOMMP starting at address FFFF F100 0300. According to the structure on page 155 of the manual, this...moreHello, I am trying to understand how to interrupt the high-density channel data located in the OPTOMMP starting at address FFFF F100 0300. According to the structure on page 155 of the manual, this section should have the analog channels value in engineering units and the feature data for digital channels. image898×508 86.9 KB For now, I am trying to read the state of a digital output from a GRV-ODCI-12 card located in slot 0. The controller is a GRV-EPIC-PR1. From looking at the Generic MMP usi...... <less A problem in TCP/IP communication Forum - Published: A R1 controller and 10 temperature and humidity modules communicate through Ethernet. The control strategy in R1 uses an Ethernet communication handle to connect different temperature and humidity...moreA R1 controller and 10 temperature and humidity modules communicate through Ethernet. The control strategy in R1 uses an Ethernet communication handle to connect different temperature and humidity meters by changing the parameters of the communication handle. The R1 controller is the client of TCP communication. To test the effectiveness of TCP communication, I set the polling interval to 100ms, so there is no need for such fast polling during normal use. R1 has been running normally for several...... <less Issue in Opto 22 Groov EPIC PR2 Forum - Published: We are facing critical issues in our current setup involving OPTO 22 GROOV EPIC PR2 PLC and the Ignition Full V8.17 system. Our system configuration includes- OPTO 22 PLC: First Ethernet port- Serum...moreWe are facing critical issues in our current setup involving OPTO 22 GROOV EPIC PR2 PLC and the Ignition Full V8.17 system. Our system configuration includes- OPTO 22 PLC: First Ethernet port- Serum Corporate IP & Second Ethernet port- Local IP of Siemens PLC network. Implemented Data store-and-forward within the OPTO 22 PLC. Established communication between Ignition and 6 nos of Siemens PLCs using OPC devices within the OPTO 22. Integration of 6 databases communication with SQL 2019 in...... <less « PreviousPage 4 of 128Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Printer Interface via an EPIC Controller Forum - Published: Have an existing system using an EPIC controller (PACProject) with Groov View via the HDMI port that needs to print reports. The intent is to try to do this without adding a PC to the system. I’ve done...moreHave an existing system using an EPIC controller (PACProject) with Groov View via the HDMI port that needs to print reports. The intent is to try to do this without adding a PC to the system. I’ve done ASCII to Serial (RS232) Printers years ago (via PACProject and an PAC-R) BUT serial printers are not as common today (most are for labels or receipts). Is there a way (or has anybody already done this) via Node-Red, PACControl, shell access, etc. that we can send our Text Files to a standard Ether...... <less Question On Trending in Groov View Forum - Published: Good morning. My situation is… I’m using the trial version of Groov View Server for Windows on a PC currently. I have a lot of trends that are all working nicely reading PLC tags from various sources...moreGood morning. My situation is… I’m using the trial version of Groov View Server for Windows on a PC currently. I have a lot of trends that are all working nicely reading PLC tags from various sources (Coming from Node-Red EthernetIP Nodes). Currently I have to re-start the Groov Server and reopen Groov View every two hours as it’s a trial version. If I restart the server immediately upon timing out, then I retain my older data. If it sits for a bit before reopening, I lose my older data. My ques...... <less Sensors that can tap into (so we can monitor and/or manipulate) badge access to one of our more sophisticated machine shop devices, like a laser cutter Forum - Published: We’re starting our Industry 4.0 transformation with the groov RIO (& eventually EPIC) product line. We’re looking for sensors that can tap into (so we can monitor and/or manipulate) badge access to one...moreWe’re starting our Industry 4.0 transformation with the groov RIO (& eventually EPIC) product line. We’re looking for sensors that can tap into (so we can monitor and/or manipulate) badge access to one of our more sophisticated machine shop devices, like a laser cutter. We went to ensure that the technician is qualified to operate the equipment. Any thoughts or suggestions?... <less RIO Device Scan unavailable? Forum - Published: Hello everyone, Trying to play with getting this RIO (MM1001-10) going with Codesys. I have successfully connected to it and gone online, however I cannot seem to scan the device for its I/O? Do I...moreHello everyone, Trying to play with getting this RIO (MM1001-10) going with Codesys. I have successfully connected to it and gone online, however I cannot seem to scan the device for its I/O? Do I need to set up each I/O channel in Groov manage first or am I missing something? Thanks in advance!... <less Read/Write I/O using commands to read/write enter I/O unit all at once Forum - Published: This is mainly a question about OptoControl, but as we move our hardware to groov, we are looking at ways to streamline our process. We’ve recently had a lot of issues (I/O units becoming disabled and...moreThis is mainly a question about OptoControl, but as we move our hardware to groov, we are looking at ways to streamline our process. We’ve recently had a lot of issues (I/O units becoming disabled and taking to long to be able to get them communicating again is the primary issue) communicating over serial cables on our LCM4 controllers so we’ve changed how we read/write to the I/O using the the following commands: MoveMixedIoUnitToTable MoveTableToMixedIoUnit MoveAnalogIoUnitToTable MoveTableToA...... <less Node-red energy meter rs485 modbus connection Forum - Published: Hello there, i have some problems with node-re modbus connection via rs485. i have conencted raspberry to Yada dcm6636 energy meter via rs485 port. The port open and communicate each other but in node...moreHello there, i have some problems with node-re modbus connection via rs485. i have conencted raspberry to Yada dcm6636 energy meter via rs485 port. The port open and communicate each other but in node-red no values come and it give time out error. is there know this problem’s solution anyone... <less Updating node-red project API Forum - Published: Hello! I’m working on setting up a CI pipeline for our node-red project and and I would like to automate the deployment to target. I thought maybe I could use the node-red admin API. More specifically...moreHello! I’m working on setting up a CI pipeline for our node-red project and and I would like to automate the deployment to target. I thought maybe I could use the node-red admin API. More specifically the POST /flows. However, when I try to use the API all I get is this: 301 Moved Permanently 301 Moved Permanently nginx/1.20.1 Is the node-red admin API not available on the groov EPIC? Are th...... <less I want to 32 crc and 30 crc and 16 crc with my own polynomial Forum - Published: I want to 32 crc and 30 crc and 16 crc with my own polynomial ,how can I implement this using opto scripting? please reply...I want to 32 crc and 30 crc and 16 crc with my own polynomial ,how can I implement this using opto scripting? please reply... <less EtherNet/IP Configurator for Groov? Forum - Published: I’ve been experimenting this week with the EtherNet/IP Configurator for SNAP PAC hardware. Is it possible to configure similar communication for I/O attached directly to a Groov EPIC-PR1?...I’ve been experimenting this week with the EtherNet/IP Configurator for SNAP PAC hardware. Is it possible to configure similar communication for I/O attached directly to a Groov EPIC-PR1?... <less Understanding high-density channel data for streaming via UDP Forum - Published: Hello, I am trying to understand how to interrupt the high-density channel data located in the OPTOMMP starting at address FFFF F100 0300. According to the structure on page 155 of the manual, this...moreHello, I am trying to understand how to interrupt the high-density channel data located in the OPTOMMP starting at address FFFF F100 0300. According to the structure on page 155 of the manual, this section should have the analog channels value in engineering units and the feature data for digital channels. image898×508 86.9 KB For now, I am trying to read the state of a digital output from a GRV-ODCI-12 card located in slot 0. The controller is a GRV-EPIC-PR1. From looking at the Generic MMP usi...... <less A problem in TCP/IP communication Forum - Published: A R1 controller and 10 temperature and humidity modules communicate through Ethernet. The control strategy in R1 uses an Ethernet communication handle to connect different temperature and humidity...moreA R1 controller and 10 temperature and humidity modules communicate through Ethernet. The control strategy in R1 uses an Ethernet communication handle to connect different temperature and humidity meters by changing the parameters of the communication handle. The R1 controller is the client of TCP communication. To test the effectiveness of TCP communication, I set the polling interval to 100ms, so there is no need for such fast polling during normal use. R1 has been running normally for several...... <less Issue in Opto 22 Groov EPIC PR2 Forum - Published: We are facing critical issues in our current setup involving OPTO 22 GROOV EPIC PR2 PLC and the Ignition Full V8.17 system. Our system configuration includes- OPTO 22 PLC: First Ethernet port- Serum...moreWe are facing critical issues in our current setup involving OPTO 22 GROOV EPIC PR2 PLC and the Ignition Full V8.17 system. Our system configuration includes- OPTO 22 PLC: First Ethernet port- Serum Corporate IP & Second Ethernet port- Local IP of Siemens PLC network. Implemented Data store-and-forward within the OPTO 22 PLC. Established communication between Ignition and 6 nos of Siemens PLCs using OPC devices within the OPTO 22. Integration of 6 databases communication with SQL 2019 in...... <less « PreviousPage 4 of 128Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Question On Trending in Groov View Forum - Published: Good morning. My situation is… I’m using the trial version of Groov View Server for Windows on a PC currently. I have a lot of trends that are all working nicely reading PLC tags from various sources...moreGood morning. My situation is… I’m using the trial version of Groov View Server for Windows on a PC currently. I have a lot of trends that are all working nicely reading PLC tags from various sources (Coming from Node-Red EthernetIP Nodes). Currently I have to re-start the Groov Server and reopen Groov View every two hours as it’s a trial version. If I restart the server immediately upon timing out, then I retain my older data. If it sits for a bit before reopening, I lose my older data. My ques...... <less Sensors that can tap into (so we can monitor and/or manipulate) badge access to one of our more sophisticated machine shop devices, like a laser cutter Forum - Published: We’re starting our Industry 4.0 transformation with the groov RIO (& eventually EPIC) product line. We’re looking for sensors that can tap into (so we can monitor and/or manipulate) badge access to one...moreWe’re starting our Industry 4.0 transformation with the groov RIO (& eventually EPIC) product line. We’re looking for sensors that can tap into (so we can monitor and/or manipulate) badge access to one of our more sophisticated machine shop devices, like a laser cutter. We went to ensure that the technician is qualified to operate the equipment. Any thoughts or suggestions?... <less RIO Device Scan unavailable? Forum - Published: Hello everyone, Trying to play with getting this RIO (MM1001-10) going with Codesys. I have successfully connected to it and gone online, however I cannot seem to scan the device for its I/O? Do I...moreHello everyone, Trying to play with getting this RIO (MM1001-10) going with Codesys. I have successfully connected to it and gone online, however I cannot seem to scan the device for its I/O? Do I need to set up each I/O channel in Groov manage first or am I missing something? Thanks in advance!... <less Read/Write I/O using commands to read/write enter I/O unit all at once Forum - Published: This is mainly a question about OptoControl, but as we move our hardware to groov, we are looking at ways to streamline our process. We’ve recently had a lot of issues (I/O units becoming disabled and...moreThis is mainly a question about OptoControl, but as we move our hardware to groov, we are looking at ways to streamline our process. We’ve recently had a lot of issues (I/O units becoming disabled and taking to long to be able to get them communicating again is the primary issue) communicating over serial cables on our LCM4 controllers so we’ve changed how we read/write to the I/O using the the following commands: MoveMixedIoUnitToTable MoveTableToMixedIoUnit MoveAnalogIoUnitToTable MoveTableToA...... <less Node-red energy meter rs485 modbus connection Forum - Published: Hello there, i have some problems with node-re modbus connection via rs485. i have conencted raspberry to Yada dcm6636 energy meter via rs485 port. The port open and communicate each other but in node...moreHello there, i have some problems with node-re modbus connection via rs485. i have conencted raspberry to Yada dcm6636 energy meter via rs485 port. The port open and communicate each other but in node-red no values come and it give time out error. is there know this problem’s solution anyone... <less Updating node-red project API Forum - Published: Hello! I’m working on setting up a CI pipeline for our node-red project and and I would like to automate the deployment to target. I thought maybe I could use the node-red admin API. More specifically...moreHello! I’m working on setting up a CI pipeline for our node-red project and and I would like to automate the deployment to target. I thought maybe I could use the node-red admin API. More specifically the POST /flows. However, when I try to use the API all I get is this: 301 Moved Permanently 301 Moved Permanently nginx/1.20.1 Is the node-red admin API not available on the groov EPIC? Are th...... <less I want to 32 crc and 30 crc and 16 crc with my own polynomial Forum - Published: I want to 32 crc and 30 crc and 16 crc with my own polynomial ,how can I implement this using opto scripting? please reply...I want to 32 crc and 30 crc and 16 crc with my own polynomial ,how can I implement this using opto scripting? please reply... <less EtherNet/IP Configurator for Groov? Forum - Published: I’ve been experimenting this week with the EtherNet/IP Configurator for SNAP PAC hardware. Is it possible to configure similar communication for I/O attached directly to a Groov EPIC-PR1?...I’ve been experimenting this week with the EtherNet/IP Configurator for SNAP PAC hardware. Is it possible to configure similar communication for I/O attached directly to a Groov EPIC-PR1?... <less Understanding high-density channel data for streaming via UDP Forum - Published: Hello, I am trying to understand how to interrupt the high-density channel data located in the OPTOMMP starting at address FFFF F100 0300. According to the structure on page 155 of the manual, this...moreHello, I am trying to understand how to interrupt the high-density channel data located in the OPTOMMP starting at address FFFF F100 0300. According to the structure on page 155 of the manual, this section should have the analog channels value in engineering units and the feature data for digital channels. image898×508 86.9 KB For now, I am trying to read the state of a digital output from a GRV-ODCI-12 card located in slot 0. The controller is a GRV-EPIC-PR1. From looking at the Generic MMP usi...... <less A problem in TCP/IP communication Forum - Published: A R1 controller and 10 temperature and humidity modules communicate through Ethernet. The control strategy in R1 uses an Ethernet communication handle to connect different temperature and humidity...moreA R1 controller and 10 temperature and humidity modules communicate through Ethernet. The control strategy in R1 uses an Ethernet communication handle to connect different temperature and humidity meters by changing the parameters of the communication handle. The R1 controller is the client of TCP communication. To test the effectiveness of TCP communication, I set the polling interval to 100ms, so there is no need for such fast polling during normal use. R1 has been running normally for several...... <less Issue in Opto 22 Groov EPIC PR2 Forum - Published: We are facing critical issues in our current setup involving OPTO 22 GROOV EPIC PR2 PLC and the Ignition Full V8.17 system. Our system configuration includes- OPTO 22 PLC: First Ethernet port- Serum...moreWe are facing critical issues in our current setup involving OPTO 22 GROOV EPIC PR2 PLC and the Ignition Full V8.17 system. Our system configuration includes- OPTO 22 PLC: First Ethernet port- Serum Corporate IP & Second Ethernet port- Local IP of Siemens PLC network. Implemented Data store-and-forward within the OPTO 22 PLC. Established communication between Ignition and 6 nos of Siemens PLCs using OPC devices within the OPTO 22. Integration of 6 databases communication with SQL 2019 in...... <less « PreviousPage 4 of 128Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Sensors that can tap into (so we can monitor and/or manipulate) badge access to one of our more sophisticated machine shop devices, like a laser cutter Forum - Published: We’re starting our Industry 4.0 transformation with the groov RIO (& eventually EPIC) product line. We’re looking for sensors that can tap into (so we can monitor and/or manipulate) badge access to one...moreWe’re starting our Industry 4.0 transformation with the groov RIO (& eventually EPIC) product line. We’re looking for sensors that can tap into (so we can monitor and/or manipulate) badge access to one of our more sophisticated machine shop devices, like a laser cutter. We went to ensure that the technician is qualified to operate the equipment. Any thoughts or suggestions?... <less RIO Device Scan unavailable? Forum - Published: Hello everyone, Trying to play with getting this RIO (MM1001-10) going with Codesys. I have successfully connected to it and gone online, however I cannot seem to scan the device for its I/O? Do I...moreHello everyone, Trying to play with getting this RIO (MM1001-10) going with Codesys. I have successfully connected to it and gone online, however I cannot seem to scan the device for its I/O? Do I need to set up each I/O channel in Groov manage first or am I missing something? Thanks in advance!... <less Read/Write I/O using commands to read/write enter I/O unit all at once Forum - Published: This is mainly a question about OptoControl, but as we move our hardware to groov, we are looking at ways to streamline our process. We’ve recently had a lot of issues (I/O units becoming disabled and...moreThis is mainly a question about OptoControl, but as we move our hardware to groov, we are looking at ways to streamline our process. We’ve recently had a lot of issues (I/O units becoming disabled and taking to long to be able to get them communicating again is the primary issue) communicating over serial cables on our LCM4 controllers so we’ve changed how we read/write to the I/O using the the following commands: MoveMixedIoUnitToTable MoveTableToMixedIoUnit MoveAnalogIoUnitToTable MoveTableToA...... <less Node-red energy meter rs485 modbus connection Forum - Published: Hello there, i have some problems with node-re modbus connection via rs485. i have conencted raspberry to Yada dcm6636 energy meter via rs485 port. The port open and communicate each other but in node...moreHello there, i have some problems with node-re modbus connection via rs485. i have conencted raspberry to Yada dcm6636 energy meter via rs485 port. The port open and communicate each other but in node-red no values come and it give time out error. is there know this problem’s solution anyone... <less Updating node-red project API Forum - Published: Hello! I’m working on setting up a CI pipeline for our node-red project and and I would like to automate the deployment to target. I thought maybe I could use the node-red admin API. More specifically...moreHello! I’m working on setting up a CI pipeline for our node-red project and and I would like to automate the deployment to target. I thought maybe I could use the node-red admin API. More specifically the POST /flows. However, when I try to use the API all I get is this: 301 Moved Permanently 301 Moved Permanently nginx/1.20.1 Is the node-red admin API not available on the groov EPIC? Are th...... <less I want to 32 crc and 30 crc and 16 crc with my own polynomial Forum - Published: I want to 32 crc and 30 crc and 16 crc with my own polynomial ,how can I implement this using opto scripting? please reply...I want to 32 crc and 30 crc and 16 crc with my own polynomial ,how can I implement this using opto scripting? please reply... <less EtherNet/IP Configurator for Groov? Forum - Published: I’ve been experimenting this week with the EtherNet/IP Configurator for SNAP PAC hardware. Is it possible to configure similar communication for I/O attached directly to a Groov EPIC-PR1?...I’ve been experimenting this week with the EtherNet/IP Configurator for SNAP PAC hardware. Is it possible to configure similar communication for I/O attached directly to a Groov EPIC-PR1?... <less Understanding high-density channel data for streaming via UDP Forum - Published: Hello, I am trying to understand how to interrupt the high-density channel data located in the OPTOMMP starting at address FFFF F100 0300. According to the structure on page 155 of the manual, this...moreHello, I am trying to understand how to interrupt the high-density channel data located in the OPTOMMP starting at address FFFF F100 0300. According to the structure on page 155 of the manual, this section should have the analog channels value in engineering units and the feature data for digital channels. image898×508 86.9 KB For now, I am trying to read the state of a digital output from a GRV-ODCI-12 card located in slot 0. The controller is a GRV-EPIC-PR1. From looking at the Generic MMP usi...... <less A problem in TCP/IP communication Forum - Published: A R1 controller and 10 temperature and humidity modules communicate through Ethernet. The control strategy in R1 uses an Ethernet communication handle to connect different temperature and humidity...moreA R1 controller and 10 temperature and humidity modules communicate through Ethernet. The control strategy in R1 uses an Ethernet communication handle to connect different temperature and humidity meters by changing the parameters of the communication handle. The R1 controller is the client of TCP communication. To test the effectiveness of TCP communication, I set the polling interval to 100ms, so there is no need for such fast polling during normal use. R1 has been running normally for several...... <less Issue in Opto 22 Groov EPIC PR2 Forum - Published: We are facing critical issues in our current setup involving OPTO 22 GROOV EPIC PR2 PLC and the Ignition Full V8.17 system. Our system configuration includes- OPTO 22 PLC: First Ethernet port- Serum...moreWe are facing critical issues in our current setup involving OPTO 22 GROOV EPIC PR2 PLC and the Ignition Full V8.17 system. Our system configuration includes- OPTO 22 PLC: First Ethernet port- Serum Corporate IP & Second Ethernet port- Local IP of Siemens PLC network. Implemented Data store-and-forward within the OPTO 22 PLC. Established communication between Ignition and 6 nos of Siemens PLCs using OPC devices within the OPTO 22. Integration of 6 databases communication with SQL 2019 in...... <less « PreviousPage 4 of 128Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
RIO Device Scan unavailable? Forum - Published: Hello everyone, Trying to play with getting this RIO (MM1001-10) going with Codesys. I have successfully connected to it and gone online, however I cannot seem to scan the device for its I/O? Do I...moreHello everyone, Trying to play with getting this RIO (MM1001-10) going with Codesys. I have successfully connected to it and gone online, however I cannot seem to scan the device for its I/O? Do I need to set up each I/O channel in Groov manage first or am I missing something? Thanks in advance!... <less Read/Write I/O using commands to read/write enter I/O unit all at once Forum - Published: This is mainly a question about OptoControl, but as we move our hardware to groov, we are looking at ways to streamline our process. We’ve recently had a lot of issues (I/O units becoming disabled and...moreThis is mainly a question about OptoControl, but as we move our hardware to groov, we are looking at ways to streamline our process. We’ve recently had a lot of issues (I/O units becoming disabled and taking to long to be able to get them communicating again is the primary issue) communicating over serial cables on our LCM4 controllers so we’ve changed how we read/write to the I/O using the the following commands: MoveMixedIoUnitToTable MoveTableToMixedIoUnit MoveAnalogIoUnitToTable MoveTableToA...... <less Node-red energy meter rs485 modbus connection Forum - Published: Hello there, i have some problems with node-re modbus connection via rs485. i have conencted raspberry to Yada dcm6636 energy meter via rs485 port. The port open and communicate each other but in node...moreHello there, i have some problems with node-re modbus connection via rs485. i have conencted raspberry to Yada dcm6636 energy meter via rs485 port. The port open and communicate each other but in node-red no values come and it give time out error. is there know this problem’s solution anyone... <less Updating node-red project API Forum - Published: Hello! I’m working on setting up a CI pipeline for our node-red project and and I would like to automate the deployment to target. I thought maybe I could use the node-red admin API. More specifically...moreHello! I’m working on setting up a CI pipeline for our node-red project and and I would like to automate the deployment to target. I thought maybe I could use the node-red admin API. More specifically the POST /flows. However, when I try to use the API all I get is this: 301 Moved Permanently 301 Moved Permanently nginx/1.20.1 Is the node-red admin API not available on the groov EPIC? Are th...... <less I want to 32 crc and 30 crc and 16 crc with my own polynomial Forum - Published: I want to 32 crc and 30 crc and 16 crc with my own polynomial ,how can I implement this using opto scripting? please reply...I want to 32 crc and 30 crc and 16 crc with my own polynomial ,how can I implement this using opto scripting? please reply... <less EtherNet/IP Configurator for Groov? Forum - Published: I’ve been experimenting this week with the EtherNet/IP Configurator for SNAP PAC hardware. Is it possible to configure similar communication for I/O attached directly to a Groov EPIC-PR1?...I’ve been experimenting this week with the EtherNet/IP Configurator for SNAP PAC hardware. Is it possible to configure similar communication for I/O attached directly to a Groov EPIC-PR1?... <less Understanding high-density channel data for streaming via UDP Forum - Published: Hello, I am trying to understand how to interrupt the high-density channel data located in the OPTOMMP starting at address FFFF F100 0300. According to the structure on page 155 of the manual, this...moreHello, I am trying to understand how to interrupt the high-density channel data located in the OPTOMMP starting at address FFFF F100 0300. According to the structure on page 155 of the manual, this section should have the analog channels value in engineering units and the feature data for digital channels. image898×508 86.9 KB For now, I am trying to read the state of a digital output from a GRV-ODCI-12 card located in slot 0. The controller is a GRV-EPIC-PR1. From looking at the Generic MMP usi...... <less A problem in TCP/IP communication Forum - Published: A R1 controller and 10 temperature and humidity modules communicate through Ethernet. The control strategy in R1 uses an Ethernet communication handle to connect different temperature and humidity...moreA R1 controller and 10 temperature and humidity modules communicate through Ethernet. The control strategy in R1 uses an Ethernet communication handle to connect different temperature and humidity meters by changing the parameters of the communication handle. The R1 controller is the client of TCP communication. To test the effectiveness of TCP communication, I set the polling interval to 100ms, so there is no need for such fast polling during normal use. R1 has been running normally for several...... <less Issue in Opto 22 Groov EPIC PR2 Forum - Published: We are facing critical issues in our current setup involving OPTO 22 GROOV EPIC PR2 PLC and the Ignition Full V8.17 system. Our system configuration includes- OPTO 22 PLC: First Ethernet port- Serum...moreWe are facing critical issues in our current setup involving OPTO 22 GROOV EPIC PR2 PLC and the Ignition Full V8.17 system. Our system configuration includes- OPTO 22 PLC: First Ethernet port- Serum Corporate IP & Second Ethernet port- Local IP of Siemens PLC network. Implemented Data store-and-forward within the OPTO 22 PLC. Established communication between Ignition and 6 nos of Siemens PLCs using OPC devices within the OPTO 22. Integration of 6 databases communication with SQL 2019 in...... <less « PreviousPage 4 of 128Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Read/Write I/O using commands to read/write enter I/O unit all at once Forum - Published: This is mainly a question about OptoControl, but as we move our hardware to groov, we are looking at ways to streamline our process. We’ve recently had a lot of issues (I/O units becoming disabled and...moreThis is mainly a question about OptoControl, but as we move our hardware to groov, we are looking at ways to streamline our process. We’ve recently had a lot of issues (I/O units becoming disabled and taking to long to be able to get them communicating again is the primary issue) communicating over serial cables on our LCM4 controllers so we’ve changed how we read/write to the I/O using the the following commands: MoveMixedIoUnitToTable MoveTableToMixedIoUnit MoveAnalogIoUnitToTable MoveTableToA...... <less Node-red energy meter rs485 modbus connection Forum - Published: Hello there, i have some problems with node-re modbus connection via rs485. i have conencted raspberry to Yada dcm6636 energy meter via rs485 port. The port open and communicate each other but in node...moreHello there, i have some problems with node-re modbus connection via rs485. i have conencted raspberry to Yada dcm6636 energy meter via rs485 port. The port open and communicate each other but in node-red no values come and it give time out error. is there know this problem’s solution anyone... <less Updating node-red project API Forum - Published: Hello! I’m working on setting up a CI pipeline for our node-red project and and I would like to automate the deployment to target. I thought maybe I could use the node-red admin API. More specifically...moreHello! I’m working on setting up a CI pipeline for our node-red project and and I would like to automate the deployment to target. I thought maybe I could use the node-red admin API. More specifically the POST /flows. However, when I try to use the API all I get is this: 301 Moved Permanently 301 Moved Permanently nginx/1.20.1 Is the node-red admin API not available on the groov EPIC? Are th...... <less I want to 32 crc and 30 crc and 16 crc with my own polynomial Forum - Published: I want to 32 crc and 30 crc and 16 crc with my own polynomial ,how can I implement this using opto scripting? please reply...I want to 32 crc and 30 crc and 16 crc with my own polynomial ,how can I implement this using opto scripting? please reply... <less EtherNet/IP Configurator for Groov? Forum - Published: I’ve been experimenting this week with the EtherNet/IP Configurator for SNAP PAC hardware. Is it possible to configure similar communication for I/O attached directly to a Groov EPIC-PR1?...I’ve been experimenting this week with the EtherNet/IP Configurator for SNAP PAC hardware. Is it possible to configure similar communication for I/O attached directly to a Groov EPIC-PR1?... <less Understanding high-density channel data for streaming via UDP Forum - Published: Hello, I am trying to understand how to interrupt the high-density channel data located in the OPTOMMP starting at address FFFF F100 0300. According to the structure on page 155 of the manual, this...moreHello, I am trying to understand how to interrupt the high-density channel data located in the OPTOMMP starting at address FFFF F100 0300. According to the structure on page 155 of the manual, this section should have the analog channels value in engineering units and the feature data for digital channels. image898×508 86.9 KB For now, I am trying to read the state of a digital output from a GRV-ODCI-12 card located in slot 0. The controller is a GRV-EPIC-PR1. From looking at the Generic MMP usi...... <less A problem in TCP/IP communication Forum - Published: A R1 controller and 10 temperature and humidity modules communicate through Ethernet. The control strategy in R1 uses an Ethernet communication handle to connect different temperature and humidity...moreA R1 controller and 10 temperature and humidity modules communicate through Ethernet. The control strategy in R1 uses an Ethernet communication handle to connect different temperature and humidity meters by changing the parameters of the communication handle. The R1 controller is the client of TCP communication. To test the effectiveness of TCP communication, I set the polling interval to 100ms, so there is no need for such fast polling during normal use. R1 has been running normally for several...... <less Issue in Opto 22 Groov EPIC PR2 Forum - Published: We are facing critical issues in our current setup involving OPTO 22 GROOV EPIC PR2 PLC and the Ignition Full V8.17 system. Our system configuration includes- OPTO 22 PLC: First Ethernet port- Serum...moreWe are facing critical issues in our current setup involving OPTO 22 GROOV EPIC PR2 PLC and the Ignition Full V8.17 system. Our system configuration includes- OPTO 22 PLC: First Ethernet port- Serum Corporate IP & Second Ethernet port- Local IP of Siemens PLC network. Implemented Data store-and-forward within the OPTO 22 PLC. Established communication between Ignition and 6 nos of Siemens PLCs using OPC devices within the OPTO 22. Integration of 6 databases communication with SQL 2019 in...... <less « PreviousPage 4 of 128Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Node-red energy meter rs485 modbus connection Forum - Published: Hello there, i have some problems with node-re modbus connection via rs485. i have conencted raspberry to Yada dcm6636 energy meter via rs485 port. The port open and communicate each other but in node...moreHello there, i have some problems with node-re modbus connection via rs485. i have conencted raspberry to Yada dcm6636 energy meter via rs485 port. The port open and communicate each other but in node-red no values come and it give time out error. is there know this problem’s solution anyone... <less Updating node-red project API Forum - Published: Hello! I’m working on setting up a CI pipeline for our node-red project and and I would like to automate the deployment to target. I thought maybe I could use the node-red admin API. More specifically...moreHello! I’m working on setting up a CI pipeline for our node-red project and and I would like to automate the deployment to target. I thought maybe I could use the node-red admin API. More specifically the POST /flows. However, when I try to use the API all I get is this: 301 Moved Permanently 301 Moved Permanently nginx/1.20.1 Is the node-red admin API not available on the groov EPIC? Are th...... <less I want to 32 crc and 30 crc and 16 crc with my own polynomial Forum - Published: I want to 32 crc and 30 crc and 16 crc with my own polynomial ,how can I implement this using opto scripting? please reply...I want to 32 crc and 30 crc and 16 crc with my own polynomial ,how can I implement this using opto scripting? please reply... <less EtherNet/IP Configurator for Groov? Forum - Published: I’ve been experimenting this week with the EtherNet/IP Configurator for SNAP PAC hardware. Is it possible to configure similar communication for I/O attached directly to a Groov EPIC-PR1?...I’ve been experimenting this week with the EtherNet/IP Configurator for SNAP PAC hardware. Is it possible to configure similar communication for I/O attached directly to a Groov EPIC-PR1?... <less Understanding high-density channel data for streaming via UDP Forum - Published: Hello, I am trying to understand how to interrupt the high-density channel data located in the OPTOMMP starting at address FFFF F100 0300. According to the structure on page 155 of the manual, this...moreHello, I am trying to understand how to interrupt the high-density channel data located in the OPTOMMP starting at address FFFF F100 0300. According to the structure on page 155 of the manual, this section should have the analog channels value in engineering units and the feature data for digital channels. image898×508 86.9 KB For now, I am trying to read the state of a digital output from a GRV-ODCI-12 card located in slot 0. The controller is a GRV-EPIC-PR1. From looking at the Generic MMP usi...... <less A problem in TCP/IP communication Forum - Published: A R1 controller and 10 temperature and humidity modules communicate through Ethernet. The control strategy in R1 uses an Ethernet communication handle to connect different temperature and humidity...moreA R1 controller and 10 temperature and humidity modules communicate through Ethernet. The control strategy in R1 uses an Ethernet communication handle to connect different temperature and humidity meters by changing the parameters of the communication handle. The R1 controller is the client of TCP communication. To test the effectiveness of TCP communication, I set the polling interval to 100ms, so there is no need for such fast polling during normal use. R1 has been running normally for several...... <less Issue in Opto 22 Groov EPIC PR2 Forum - Published: We are facing critical issues in our current setup involving OPTO 22 GROOV EPIC PR2 PLC and the Ignition Full V8.17 system. Our system configuration includes- OPTO 22 PLC: First Ethernet port- Serum...moreWe are facing critical issues in our current setup involving OPTO 22 GROOV EPIC PR2 PLC and the Ignition Full V8.17 system. Our system configuration includes- OPTO 22 PLC: First Ethernet port- Serum Corporate IP & Second Ethernet port- Local IP of Siemens PLC network. Implemented Data store-and-forward within the OPTO 22 PLC. Established communication between Ignition and 6 nos of Siemens PLCs using OPC devices within the OPTO 22. Integration of 6 databases communication with SQL 2019 in...... <less « PreviousPage 4 of 128Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Updating node-red project API Forum - Published: Hello! I’m working on setting up a CI pipeline for our node-red project and and I would like to automate the deployment to target. I thought maybe I could use the node-red admin API. More specifically...moreHello! I’m working on setting up a CI pipeline for our node-red project and and I would like to automate the deployment to target. I thought maybe I could use the node-red admin API. More specifically the POST /flows. However, when I try to use the API all I get is this: 301 Moved Permanently 301 Moved Permanently nginx/1.20.1 Is the node-red admin API not available on the groov EPIC? Are th...... <less I want to 32 crc and 30 crc and 16 crc with my own polynomial Forum - Published: I want to 32 crc and 30 crc and 16 crc with my own polynomial ,how can I implement this using opto scripting? please reply...I want to 32 crc and 30 crc and 16 crc with my own polynomial ,how can I implement this using opto scripting? please reply... <less EtherNet/IP Configurator for Groov? Forum - Published: I’ve been experimenting this week with the EtherNet/IP Configurator for SNAP PAC hardware. Is it possible to configure similar communication for I/O attached directly to a Groov EPIC-PR1?...I’ve been experimenting this week with the EtherNet/IP Configurator for SNAP PAC hardware. Is it possible to configure similar communication for I/O attached directly to a Groov EPIC-PR1?... <less Understanding high-density channel data for streaming via UDP Forum - Published: Hello, I am trying to understand how to interrupt the high-density channel data located in the OPTOMMP starting at address FFFF F100 0300. According to the structure on page 155 of the manual, this...moreHello, I am trying to understand how to interrupt the high-density channel data located in the OPTOMMP starting at address FFFF F100 0300. According to the structure on page 155 of the manual, this section should have the analog channels value in engineering units and the feature data for digital channels. image898×508 86.9 KB For now, I am trying to read the state of a digital output from a GRV-ODCI-12 card located in slot 0. The controller is a GRV-EPIC-PR1. From looking at the Generic MMP usi...... <less A problem in TCP/IP communication Forum - Published: A R1 controller and 10 temperature and humidity modules communicate through Ethernet. The control strategy in R1 uses an Ethernet communication handle to connect different temperature and humidity...moreA R1 controller and 10 temperature and humidity modules communicate through Ethernet. The control strategy in R1 uses an Ethernet communication handle to connect different temperature and humidity meters by changing the parameters of the communication handle. The R1 controller is the client of TCP communication. To test the effectiveness of TCP communication, I set the polling interval to 100ms, so there is no need for such fast polling during normal use. R1 has been running normally for several...... <less Issue in Opto 22 Groov EPIC PR2 Forum - Published: We are facing critical issues in our current setup involving OPTO 22 GROOV EPIC PR2 PLC and the Ignition Full V8.17 system. Our system configuration includes- OPTO 22 PLC: First Ethernet port- Serum...moreWe are facing critical issues in our current setup involving OPTO 22 GROOV EPIC PR2 PLC and the Ignition Full V8.17 system. Our system configuration includes- OPTO 22 PLC: First Ethernet port- Serum Corporate IP & Second Ethernet port- Local IP of Siemens PLC network. Implemented Data store-and-forward within the OPTO 22 PLC. Established communication between Ignition and 6 nos of Siemens PLCs using OPC devices within the OPTO 22. Integration of 6 databases communication with SQL 2019 in...... <less « PreviousPage 4 of 128Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
I want to 32 crc and 30 crc and 16 crc with my own polynomial Forum - Published: I want to 32 crc and 30 crc and 16 crc with my own polynomial ,how can I implement this using opto scripting? please reply...I want to 32 crc and 30 crc and 16 crc with my own polynomial ,how can I implement this using opto scripting? please reply... <less EtherNet/IP Configurator for Groov? Forum - Published: I’ve been experimenting this week with the EtherNet/IP Configurator for SNAP PAC hardware. Is it possible to configure similar communication for I/O attached directly to a Groov EPIC-PR1?...I’ve been experimenting this week with the EtherNet/IP Configurator for SNAP PAC hardware. Is it possible to configure similar communication for I/O attached directly to a Groov EPIC-PR1?... <less Understanding high-density channel data for streaming via UDP Forum - Published: Hello, I am trying to understand how to interrupt the high-density channel data located in the OPTOMMP starting at address FFFF F100 0300. According to the structure on page 155 of the manual, this...moreHello, I am trying to understand how to interrupt the high-density channel data located in the OPTOMMP starting at address FFFF F100 0300. According to the structure on page 155 of the manual, this section should have the analog channels value in engineering units and the feature data for digital channels. image898×508 86.9 KB For now, I am trying to read the state of a digital output from a GRV-ODCI-12 card located in slot 0. The controller is a GRV-EPIC-PR1. From looking at the Generic MMP usi...... <less A problem in TCP/IP communication Forum - Published: A R1 controller and 10 temperature and humidity modules communicate through Ethernet. The control strategy in R1 uses an Ethernet communication handle to connect different temperature and humidity...moreA R1 controller and 10 temperature and humidity modules communicate through Ethernet. The control strategy in R1 uses an Ethernet communication handle to connect different temperature and humidity meters by changing the parameters of the communication handle. The R1 controller is the client of TCP communication. To test the effectiveness of TCP communication, I set the polling interval to 100ms, so there is no need for such fast polling during normal use. R1 has been running normally for several...... <less Issue in Opto 22 Groov EPIC PR2 Forum - Published: We are facing critical issues in our current setup involving OPTO 22 GROOV EPIC PR2 PLC and the Ignition Full V8.17 system. Our system configuration includes- OPTO 22 PLC: First Ethernet port- Serum...moreWe are facing critical issues in our current setup involving OPTO 22 GROOV EPIC PR2 PLC and the Ignition Full V8.17 system. Our system configuration includes- OPTO 22 PLC: First Ethernet port- Serum Corporate IP & Second Ethernet port- Local IP of Siemens PLC network. Implemented Data store-and-forward within the OPTO 22 PLC. Established communication between Ignition and 6 nos of Siemens PLCs using OPC devices within the OPTO 22. Integration of 6 databases communication with SQL 2019 in...... <less « PreviousPage 4 of 128Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
EtherNet/IP Configurator for Groov? Forum - Published: I’ve been experimenting this week with the EtherNet/IP Configurator for SNAP PAC hardware. Is it possible to configure similar communication for I/O attached directly to a Groov EPIC-PR1?...I’ve been experimenting this week with the EtherNet/IP Configurator for SNAP PAC hardware. Is it possible to configure similar communication for I/O attached directly to a Groov EPIC-PR1?... <less Understanding high-density channel data for streaming via UDP Forum - Published: Hello, I am trying to understand how to interrupt the high-density channel data located in the OPTOMMP starting at address FFFF F100 0300. According to the structure on page 155 of the manual, this...moreHello, I am trying to understand how to interrupt the high-density channel data located in the OPTOMMP starting at address FFFF F100 0300. According to the structure on page 155 of the manual, this section should have the analog channels value in engineering units and the feature data for digital channels. image898×508 86.9 KB For now, I am trying to read the state of a digital output from a GRV-ODCI-12 card located in slot 0. The controller is a GRV-EPIC-PR1. From looking at the Generic MMP usi...... <less A problem in TCP/IP communication Forum - Published: A R1 controller and 10 temperature and humidity modules communicate through Ethernet. The control strategy in R1 uses an Ethernet communication handle to connect different temperature and humidity...moreA R1 controller and 10 temperature and humidity modules communicate through Ethernet. The control strategy in R1 uses an Ethernet communication handle to connect different temperature and humidity meters by changing the parameters of the communication handle. The R1 controller is the client of TCP communication. To test the effectiveness of TCP communication, I set the polling interval to 100ms, so there is no need for such fast polling during normal use. R1 has been running normally for several...... <less Issue in Opto 22 Groov EPIC PR2 Forum - Published: We are facing critical issues in our current setup involving OPTO 22 GROOV EPIC PR2 PLC and the Ignition Full V8.17 system. Our system configuration includes- OPTO 22 PLC: First Ethernet port- Serum...moreWe are facing critical issues in our current setup involving OPTO 22 GROOV EPIC PR2 PLC and the Ignition Full V8.17 system. Our system configuration includes- OPTO 22 PLC: First Ethernet port- Serum Corporate IP & Second Ethernet port- Local IP of Siemens PLC network. Implemented Data store-and-forward within the OPTO 22 PLC. Established communication between Ignition and 6 nos of Siemens PLCs using OPC devices within the OPTO 22. Integration of 6 databases communication with SQL 2019 in...... <less « PreviousPage 4 of 128Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Understanding high-density channel data for streaming via UDP Forum - Published: Hello, I am trying to understand how to interrupt the high-density channel data located in the OPTOMMP starting at address FFFF F100 0300. According to the structure on page 155 of the manual, this...moreHello, I am trying to understand how to interrupt the high-density channel data located in the OPTOMMP starting at address FFFF F100 0300. According to the structure on page 155 of the manual, this section should have the analog channels value in engineering units and the feature data for digital channels. image898×508 86.9 KB For now, I am trying to read the state of a digital output from a GRV-ODCI-12 card located in slot 0. The controller is a GRV-EPIC-PR1. From looking at the Generic MMP usi...... <less A problem in TCP/IP communication Forum - Published: A R1 controller and 10 temperature and humidity modules communicate through Ethernet. The control strategy in R1 uses an Ethernet communication handle to connect different temperature and humidity...moreA R1 controller and 10 temperature and humidity modules communicate through Ethernet. The control strategy in R1 uses an Ethernet communication handle to connect different temperature and humidity meters by changing the parameters of the communication handle. The R1 controller is the client of TCP communication. To test the effectiveness of TCP communication, I set the polling interval to 100ms, so there is no need for such fast polling during normal use. R1 has been running normally for several...... <less Issue in Opto 22 Groov EPIC PR2 Forum - Published: We are facing critical issues in our current setup involving OPTO 22 GROOV EPIC PR2 PLC and the Ignition Full V8.17 system. Our system configuration includes- OPTO 22 PLC: First Ethernet port- Serum...moreWe are facing critical issues in our current setup involving OPTO 22 GROOV EPIC PR2 PLC and the Ignition Full V8.17 system. Our system configuration includes- OPTO 22 PLC: First Ethernet port- Serum Corporate IP & Second Ethernet port- Local IP of Siemens PLC network. Implemented Data store-and-forward within the OPTO 22 PLC. Established communication between Ignition and 6 nos of Siemens PLCs using OPC devices within the OPTO 22. Integration of 6 databases communication with SQL 2019 in...... <less « PreviousPage 4 of 128Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
A problem in TCP/IP communication Forum - Published: A R1 controller and 10 temperature and humidity modules communicate through Ethernet. The control strategy in R1 uses an Ethernet communication handle to connect different temperature and humidity...moreA R1 controller and 10 temperature and humidity modules communicate through Ethernet. The control strategy in R1 uses an Ethernet communication handle to connect different temperature and humidity meters by changing the parameters of the communication handle. The R1 controller is the client of TCP communication. To test the effectiveness of TCP communication, I set the polling interval to 100ms, so there is no need for such fast polling during normal use. R1 has been running normally for several...... <less Issue in Opto 22 Groov EPIC PR2 Forum - Published: We are facing critical issues in our current setup involving OPTO 22 GROOV EPIC PR2 PLC and the Ignition Full V8.17 system. Our system configuration includes- OPTO 22 PLC: First Ethernet port- Serum...moreWe are facing critical issues in our current setup involving OPTO 22 GROOV EPIC PR2 PLC and the Ignition Full V8.17 system. Our system configuration includes- OPTO 22 PLC: First Ethernet port- Serum Corporate IP & Second Ethernet port- Local IP of Siemens PLC network. Implemented Data store-and-forward within the OPTO 22 PLC. Established communication between Ignition and 6 nos of Siemens PLCs using OPC devices within the OPTO 22. Integration of 6 databases communication with SQL 2019 in...... <less « PreviousPage 4 of 128Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Issue in Opto 22 Groov EPIC PR2 Forum - Published: We are facing critical issues in our current setup involving OPTO 22 GROOV EPIC PR2 PLC and the Ignition Full V8.17 system. Our system configuration includes- OPTO 22 PLC: First Ethernet port- Serum...moreWe are facing critical issues in our current setup involving OPTO 22 GROOV EPIC PR2 PLC and the Ignition Full V8.17 system. Our system configuration includes- OPTO 22 PLC: First Ethernet port- Serum Corporate IP & Second Ethernet port- Local IP of Siemens PLC network. Implemented Data store-and-forward within the OPTO 22 PLC. Established communication between Ignition and 6 nos of Siemens PLCs using OPC devices within the OPTO 22. Integration of 6 databases communication with SQL 2019 in...... <less « PreviousPage 4 of 128Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items