Networking issues with the groov rio Forum - Published: Hello, I recently encountered a problem with our groov rio data acquisition node. I found the problem was that the system time had changed to 20min in the future. After some testing, I found that the...moreHello, I recently encountered a problem with our groov rio data acquisition node. I found the problem was that the system time had changed to 20min in the future. After some testing, I found that the groov rio could not reach the NTP servers for the correct time. The rio is setup with a static ip and I’m able to push data to our influxdb server on the network. I am able to ping the gateway and dns servers successfully, but I’m unable to ping any public servers (ie. 8.8.8.8). If I add dns server ...... <less /home/dev/unsecured/ Permissions via Node Red Dashboard Forum - Published: I am using the following link to download .csv files from a node red dashboard ui_template. It works when the user logged in has System-wide Administrator rights. I get a forbidden message in the browser...moreI am using the following link to download .csv files from a node red dashboard ui_template. It works when the user logged in has System-wide Administrator rights. I get a forbidden message in the browser when the user is logged in isn’t a System-wide Administrator and the Node Red Permission is set to Dashboard UI. Is there a way for me to allow dashboard users access to this feature? https://10.108.5.1/manage/api/v1/files/unsecured/rpc/get-file/Stage%20Report%20Doghouse%20108%20YARD%20TED%20TES...... <less Accessing Files Stored on Groov EPIC in Ignition Edge Forum - Published: I’m using Node-RED hosted on a Groov EPIC to read data from a serial device and write it to a CSV file (stored on the EPIC at /home/dev/secured/…). I want to pull data from the CSV file into Tags in...moreI’m using Node-RED hosted on a Groov EPIC to read data from a serial device and write it to a CSV file (stored on the EPIC at /home/dev/secured/…). I want to pull data from the CSV file into Tags in Ignition Edge (using a script in Ignition Edge). I know how the syntax on the Ignition Edge side of things works, but the function that reads the file in Ignition Edge requires me to specify a filepath. I tried both of these filepaths in the Ignition Edge script, but both yielded an error saying that...... <less Optimizing PID-Loop Forum - Published: We’ve recently deployed a PAC-R1 system using one PID-Loop as its main control algorithm to maintain a target level (set point) of dissolved ozone (O3) in a large tank of water. In this application, an...moreWe’ve recently deployed a PAC-R1 system using one PID-Loop as its main control algorithm to maintain a target level (set point) of dissolved ozone (O3) in a large tank of water. In this application, an ORP sensor is used to measure the ORP level (in mV) in the water being supplied from a large water tank, which in turn will drive an analog output to an ozone generator to control how much ozone to generate and inject into the water circulating back to the tank (Output is in the range of 0% to 10...... <less How to retrieve Binary data logged with PAC Display Forum - Published: We discovered that one of the data log files has been accidentally configured to save as a “Binary” file. We can change the PAC display to save in CSV as all other data files…however, now that there is...moreWe discovered that one of the data log files has been accidentally configured to save as a “Binary” file. We can change the PAC display to save in CSV as all other data files…however, now that there is quite a bit of data saved in binary, what is a recommended way to import this data and hopefully be able to convert it to CSV to be standard with other data? Thanks for any help, Andre... <less EPIC OPC Server integer variable as boolean not working Forum - Published: I’m having problems with using the “As Boolean” in the public access for PAC Control integers not reporting the correct value in the OPC Server. Bit seems to be working (so far). Config: image620×561 48...moreI’m having problems with using the “As Boolean” in the public access for PAC Control integers not reporting the correct value in the OPC Server. Bit seems to be working (so far). Config: image620×561 48.7 KB Value in PAC Control debug: Ignition Tag Browser (just dragged the values from the + devices list): image1063×53 8.5 KB EPIC firmware 3.5.1-b.85 PAC Control Basic 10.5... <less Groov Rio Capabilities Forum - Published: Hello, I am working on scoping how to implement Groov RIO on our manufacturing floor. We have 3 Manufacturing machines with Allen Bradley PLCs that I would like to connect to and publish some tags onto a...moreHello, I am working on scoping how to implement Groov RIO on our manufacturing floor. We have 3 Manufacturing machines with Allen Bradley PLCs that I would like to connect to and publish some tags onto a dashboard to be viewed remotely by other users on the plant network. The limitation as always is the cost, and I am trying to see what the most cost-efficient way is to see that data. I am thinking about connecting 3 Groov RIOs (one to each machine) and then install a groov server on a PC wher...... <less MQTT client from Groov EPIC node red keep getting disconnected to azure eventgrid MQTT broker Forum - Published: Hi, I am running MQTT broker in microsoft azure eventgrid and I have generated certificates and keys to connect the Grooc EPIC nodered MQTT out client to eventgrid mqtt broker. When I deploy i could see...moreHi, I am running MQTT broker in microsoft azure eventgrid and I have generated certificates and keys to connect the Grooc EPIC nodered MQTT out client to eventgrid mqtt broker. When I deploy i could see it is connected for 10 seconds. After that it got disconnected and every few seconds it is showing connecting and got disconnected again. I have followed microsoft azure eventgrid tutorials for this and they gave examples for mqttx app for testing purpose. I am not sure what I am missing here and...... <less MQTT Sparkolug B message types with MQTT Sparkplug B out Forum - Published: SparkplugB_04_2024.zip (2.4 KB) Hello. I want to create all message types with “MQTT Sparkplug B out” that would work in Ignition SCADA. NBIRTH and NDATA are working but DBIRTH is rejected and I get back...moreSparkplugB_04_2024.zip (2.4 KB) Hello. I want to create all message types with “MQTT Sparkplug B out” that would work in Ignition SCADA. NBIRTH and NDATA are working but DBIRTH is rejected and I get back Rebirth control. I believe that my DBIRTH message is In accordance with Sparkplug specifications. Does anybody know how to fix the DBIRTH message that would work in Ignition SCADA? Can somebody share the flow in Node-Red where all Sparkplug b message types would work in Ignition SCADA (It can be...... <less Node-Red Sparkplub send JSON datatype Forum - Published: I am trying to set up function to send a JSON Obect to MQTT Broker using sparkplug B. The function is: var jsonObject = msg.payload; // Convert JSON object to string var jsonString = JSON.stringify...moreI am trying to set up function to send a JSON Obect to MQTT Broker using sparkplug B. The function is: var jsonObject = msg.payload; // Convert JSON object to string var jsonString = JSON.stringify(jsonObject); var sparkplugBMessage = { “metrics”: [ { “name”:“RECIPE”, “type”:12, “value”: jsonString } ] }; // Set the stringified JSON as the new payload msg.payload = sparkplugBMessage; //msg.js=jsonObject //msg.jsstring=jsonString // Return the modified message return msg; The debug results are: i...... <less Access Control Systems Forum - Published: Is anyone using any OPTO22 product to operate an Access Control System? We would entertain Wiegland or RFID proximity cards and readers. Our application includes three walk through gates with mag locks...moreIs anyone using any OPTO22 product to operate an Access Control System? We would entertain Wiegland or RFID proximity cards and readers. Our application includes three walk through gates with mag locks and two drive through gates with chain openers. Any advice would be much appreciated. Reay... <less Pac R1 to Automation Direct C More HMI through Modbus Forum - Published: I have a snap-pac-r1w and am trying to connect it to an Automation Direct C-More HMI EA9-T15CL-R Via modbus. The HMI is the master and we have the slave subroutine running in the strategy from the...moreI have a snap-pac-r1w and am trying to connect it to an Automation Direct C-More HMI EA9-T15CL-R Via modbus. The HMI is the master and we have the slave subroutine running in the strategy from the modbus integration kit. For testing purposes we are just using the supplied strategy from the modbus integration kit. Good news: Coils and Ints work fine. Bad news: When entering a float variable on the HMI it goes into the Int holding table over two consecutive values, not to the float holding t...... <less How to start the startegy automatically on power up? Forum - Published: Hello, On a Groov Epic I’d like the strategy runs automatically on power up, with no need to press a button on HMI or with PAC control. I checked the documentation, tried to find something on the forum...moreHello, On a Groov Epic I’d like the strategy runs automatically on power up, with no need to press a button on HMI or with PAC control. I checked the documentation, tried to find something on the forum but can’t get a clear answer. Thanks for your help.... <less Having a hard time with installing Tailscale on EPIC Forum - Published: Hello, I am trying to follow this guide from Corso Systems Corso Systems Tailscale on Opto22 groov Hardware | Corso Systems Corso Systems walks through setting up...moreHello, I am trying to follow this guide from Corso Systems Corso Systems Tailscale on Opto22 groov Hardware | Corso Systems Corso Systems walks through setting up Tailscale on an Opto22 groov RIO. Tailscale is built on the Wireguard framework, but can be easier to configure depending on your IT skillset. And I keep getting this error after I do the wget https://pkgs.tailscale.com/stable/tailscale_1.62.0_arm.tgz Connecting to pkgs.tails...... <less Fail to connect node-red to websocket (postman) Forum - Published: Fail to connect node-red to websocket (postman) because of Error on self signed certificate… Groove Rio, How listen to groove value to websocket… ...Fail to connect node-red to websocket (postman) because of Error on self signed certificate… Groove Rio, How listen to groove value to websocket… ... <less PAC Controller blocking port 22001? Forum - Published: I have a system using a SNAP-PAC-R1 for I/O, using an old program (Lookout by National Instruments) and we want to start using PAC Control instead. So I made a strategy and tried to download it to the...moreI have a system using a SNAP-PAC-R1 for I/O, using an old program (Lookout by National Instruments) and we want to start using PAC Control instead. So I made a strategy and tried to download it to the controller and got an error code -10057. The Ethernet connection is definitely there; I can ping the controller (10.90.150.56) from the PC with PAC Control (10.90.150.2). Both are on the same subnet. I asked my network admin if the switches might be blocking communication through port 22001, and he...... <less Groov View plug in display refresh rate Forum - Published: I have displayed the groov View interface using the local browser on a groov EPIC controller across a company network, and used a Dell touch screen monitor plugged directly into the HDMI port and USB...moreI have displayed the groov View interface using the local browser on a groov EPIC controller across a company network, and used a Dell touch screen monitor plugged directly into the HDMI port and USB port of the groov EPIC. The HDMI connection has a refresh time from 1 to 4 seconds, and the remote browsers refresh is 1 second or less. On another tech support issue, I was told that the local browser that is used for the HDMI connection has a bug and will be updated in the next firmware release of...... <less Unable to install node-red-contrib-azure-iot-hub 0.5.3 in Groov EPIC Forum - Published: Hi, I am working on Groov EPIC PR2 and want to connect to Azure-IOT-hub because my company uses azure for streaming and visualizing sensor data. When I try to install node-red-contrib-azure-iot-hub 0.5...moreHi, I am working on Groov EPIC PR2 and want to connect to Azure-IOT-hub because my company uses azure for streaming and visualizing sensor data. When I try to install node-red-contrib-azure-iot-hub 0.5.3 i got the following error. Can someone help here on this. Error log is added here for reference. 024-03-20T08:16:17.120Z Install : @nodecolor/node-red-contrib-azure-iot-hub 0.5.3 2024-03-20T08:16:18.366Z npm install --no-audit --no-update-notifier --no-fund --save --save-prefix=~ --production --...... <less Groovepic not getting connected with Vi network Forum - Published: In India Vi is a renowned mobile service provider. When I am trying to use the hotspot through Vi network then I am unable to access groovepic at my machine. PFB the IP addresses- Hotspot’s IP address...moreIn India Vi is a renowned mobile service provider. When I am trying to use the hotspot through Vi network then I am unable to access groovepic at my machine. PFB the IP addresses- Hotspot’s IP address(at my laptop accessing this IP)-192.168.116.132 IP address to access groovepic at my laptop-192.168.137.68. When I am accessing 192.168.137.68 at chrome then it throws internet timed out error message. Please suggest as to how to access groovepic at laptop through Vi hotspot... <less Can the AS-i network be connected to the R1 controller? Forum - Published: Hello everyone, one of my customers asked me about AS-i. Can his existing AS-i network be connected to the R1 controller? If it is possible, how can I do it? What equipment needs to be added? There is...moreHello everyone, one of my customers asked me about AS-i. Can his existing AS-i network be connected to the R1 controller? If it is possible, how can I do it? What equipment needs to be added? There is an AS-i master station and more than 20 AS-i actuators and sensors. Thanks!... <less Point I/O for EPIC Forum - Published: I would like to know if there is a product that could be used as a Point I/O (like the Allen Bradley Points I/O) I am using this EPIC processor that must activate more than 30 valves that are like 30...moreI would like to know if there is a product that could be used as a Point I/O (like the Allen Bradley Points I/O) I am using this EPIC processor that must activate more than 30 valves that are like 30 feet away from the device. Another EPIC will not be the best solution. I am looking for this Point I/O so I can communicate with them through ethernet IP (or similar).... <less Is There A Limit to Context Data Storage in Node-RED? Forum - Published: I have finally found a method for passing tags from Node-RED to Ignition Edge to use in Ignition Designer, but it requires storing values as Context Data in Node-RED then calling these values in the...moreI have finally found a method for passing tags from Node-RED to Ignition Edge to use in Ignition Designer, but it requires storing values as Context Data in Node-RED then calling these values in the Address Space of an OPC-UA server node (node-red-contrib-opcua-server). However, I will eventually need to pass a much higher volume of data and I’m wondering if using this method will be an issue if there is a limit to how many values I can store as Context Data.... <less Pointer to an Up Timer Forum - Published: I’ve created a pointer table containing pointers to a series of up timers. Here’s an example of how the table values are assigned, see below. SetUpTimerTarget(60, Timer_sec); ptTimerTable[0] = &Timer...moreI’ve created a pointer table containing pointers to a series of up timers. Here’s an example of how the table values are assigned, see below. SetUpTimerTarget(60, Timer_sec); ptTimerTable[0] = &Timer_sec; I then start the time in later code, see below. StartTimer(*ptTimerTable[0]); When Test Compiling I get the following syntax error. Unable to find variable or command “*ptTimerTable[0]” What am I doing wrong here? Thanks in Advance, DKMarion... <less Can I use Ignition Node-RED module with Ignition Edge Free Trial? Forum - Published: I’m attempting to set up an API Key with the Ignition Node-RED module, but am getting an error that the license is invalid. I can’t tell if this is saying that (a) I can’t use this module with Ignition...moreI’m attempting to set up an API Key with the Ignition Node-RED module, but am getting an error that the license is invalid. I can’t tell if this is saying that (a) I can’t use this module with Ignition Edge unless I have an Ignition Edge license (and am not just using the free trial) or (b) I can’t use this module with Ignition Edge because the module license itself is invalid. image1254×213 9.61 KB Has anyone come across this?... <less PAC 10.5 Analog Input - Moving Average Forum - Published: A simple questions that I cannot find documented (or I didn’t look in the right place). The new Moving Average built into the Analog Inputs can be setup to look at X Number of Samples. What determines...moreA simple questions that I cannot find documented (or I didn’t look in the right place). The new Moving Average built into the Analog Inputs can be setup to look at X Number of Samples. What determines the rate of each sample ? A moving average of 10 samples at 1 sec is very different from a moving average of 10 samples at 100msec - both of which I’ve done in the past via logic. Is it based on every time the configuration reads the point (which may or may not be at a set time base) OR is it based...... <less Page 1 of 128Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
/home/dev/unsecured/ Permissions via Node Red Dashboard Forum - Published: I am using the following link to download .csv files from a node red dashboard ui_template. It works when the user logged in has System-wide Administrator rights. I get a forbidden message in the browser...moreI am using the following link to download .csv files from a node red dashboard ui_template. It works when the user logged in has System-wide Administrator rights. I get a forbidden message in the browser when the user is logged in isn’t a System-wide Administrator and the Node Red Permission is set to Dashboard UI. Is there a way for me to allow dashboard users access to this feature? https://10.108.5.1/manage/api/v1/files/unsecured/rpc/get-file/Stage%20Report%20Doghouse%20108%20YARD%20TED%20TES...... <less Accessing Files Stored on Groov EPIC in Ignition Edge Forum - Published: I’m using Node-RED hosted on a Groov EPIC to read data from a serial device and write it to a CSV file (stored on the EPIC at /home/dev/secured/…). I want to pull data from the CSV file into Tags in...moreI’m using Node-RED hosted on a Groov EPIC to read data from a serial device and write it to a CSV file (stored on the EPIC at /home/dev/secured/…). I want to pull data from the CSV file into Tags in Ignition Edge (using a script in Ignition Edge). I know how the syntax on the Ignition Edge side of things works, but the function that reads the file in Ignition Edge requires me to specify a filepath. I tried both of these filepaths in the Ignition Edge script, but both yielded an error saying that...... <less Optimizing PID-Loop Forum - Published: We’ve recently deployed a PAC-R1 system using one PID-Loop as its main control algorithm to maintain a target level (set point) of dissolved ozone (O3) in a large tank of water. In this application, an...moreWe’ve recently deployed a PAC-R1 system using one PID-Loop as its main control algorithm to maintain a target level (set point) of dissolved ozone (O3) in a large tank of water. In this application, an ORP sensor is used to measure the ORP level (in mV) in the water being supplied from a large water tank, which in turn will drive an analog output to an ozone generator to control how much ozone to generate and inject into the water circulating back to the tank (Output is in the range of 0% to 10...... <less How to retrieve Binary data logged with PAC Display Forum - Published: We discovered that one of the data log files has been accidentally configured to save as a “Binary” file. We can change the PAC display to save in CSV as all other data files…however, now that there is...moreWe discovered that one of the data log files has been accidentally configured to save as a “Binary” file. We can change the PAC display to save in CSV as all other data files…however, now that there is quite a bit of data saved in binary, what is a recommended way to import this data and hopefully be able to convert it to CSV to be standard with other data? Thanks for any help, Andre... <less EPIC OPC Server integer variable as boolean not working Forum - Published: I’m having problems with using the “As Boolean” in the public access for PAC Control integers not reporting the correct value in the OPC Server. Bit seems to be working (so far). Config: image620×561 48...moreI’m having problems with using the “As Boolean” in the public access for PAC Control integers not reporting the correct value in the OPC Server. Bit seems to be working (so far). Config: image620×561 48.7 KB Value in PAC Control debug: Ignition Tag Browser (just dragged the values from the + devices list): image1063×53 8.5 KB EPIC firmware 3.5.1-b.85 PAC Control Basic 10.5... <less Groov Rio Capabilities Forum - Published: Hello, I am working on scoping how to implement Groov RIO on our manufacturing floor. We have 3 Manufacturing machines with Allen Bradley PLCs that I would like to connect to and publish some tags onto a...moreHello, I am working on scoping how to implement Groov RIO on our manufacturing floor. We have 3 Manufacturing machines with Allen Bradley PLCs that I would like to connect to and publish some tags onto a dashboard to be viewed remotely by other users on the plant network. The limitation as always is the cost, and I am trying to see what the most cost-efficient way is to see that data. I am thinking about connecting 3 Groov RIOs (one to each machine) and then install a groov server on a PC wher...... <less MQTT client from Groov EPIC node red keep getting disconnected to azure eventgrid MQTT broker Forum - Published: Hi, I am running MQTT broker in microsoft azure eventgrid and I have generated certificates and keys to connect the Grooc EPIC nodered MQTT out client to eventgrid mqtt broker. When I deploy i could see...moreHi, I am running MQTT broker in microsoft azure eventgrid and I have generated certificates and keys to connect the Grooc EPIC nodered MQTT out client to eventgrid mqtt broker. When I deploy i could see it is connected for 10 seconds. After that it got disconnected and every few seconds it is showing connecting and got disconnected again. I have followed microsoft azure eventgrid tutorials for this and they gave examples for mqttx app for testing purpose. I am not sure what I am missing here and...... <less MQTT Sparkolug B message types with MQTT Sparkplug B out Forum - Published: SparkplugB_04_2024.zip (2.4 KB) Hello. I want to create all message types with “MQTT Sparkplug B out” that would work in Ignition SCADA. NBIRTH and NDATA are working but DBIRTH is rejected and I get back...moreSparkplugB_04_2024.zip (2.4 KB) Hello. I want to create all message types with “MQTT Sparkplug B out” that would work in Ignition SCADA. NBIRTH and NDATA are working but DBIRTH is rejected and I get back Rebirth control. I believe that my DBIRTH message is In accordance with Sparkplug specifications. Does anybody know how to fix the DBIRTH message that would work in Ignition SCADA? Can somebody share the flow in Node-Red where all Sparkplug b message types would work in Ignition SCADA (It can be...... <less Node-Red Sparkplub send JSON datatype Forum - Published: I am trying to set up function to send a JSON Obect to MQTT Broker using sparkplug B. The function is: var jsonObject = msg.payload; // Convert JSON object to string var jsonString = JSON.stringify...moreI am trying to set up function to send a JSON Obect to MQTT Broker using sparkplug B. The function is: var jsonObject = msg.payload; // Convert JSON object to string var jsonString = JSON.stringify(jsonObject); var sparkplugBMessage = { “metrics”: [ { “name”:“RECIPE”, “type”:12, “value”: jsonString } ] }; // Set the stringified JSON as the new payload msg.payload = sparkplugBMessage; //msg.js=jsonObject //msg.jsstring=jsonString // Return the modified message return msg; The debug results are: i...... <less Access Control Systems Forum - Published: Is anyone using any OPTO22 product to operate an Access Control System? We would entertain Wiegland or RFID proximity cards and readers. Our application includes three walk through gates with mag locks...moreIs anyone using any OPTO22 product to operate an Access Control System? We would entertain Wiegland or RFID proximity cards and readers. Our application includes three walk through gates with mag locks and two drive through gates with chain openers. Any advice would be much appreciated. Reay... <less Pac R1 to Automation Direct C More HMI through Modbus Forum - Published: I have a snap-pac-r1w and am trying to connect it to an Automation Direct C-More HMI EA9-T15CL-R Via modbus. The HMI is the master and we have the slave subroutine running in the strategy from the...moreI have a snap-pac-r1w and am trying to connect it to an Automation Direct C-More HMI EA9-T15CL-R Via modbus. The HMI is the master and we have the slave subroutine running in the strategy from the modbus integration kit. For testing purposes we are just using the supplied strategy from the modbus integration kit. Good news: Coils and Ints work fine. Bad news: When entering a float variable on the HMI it goes into the Int holding table over two consecutive values, not to the float holding t...... <less How to start the startegy automatically on power up? Forum - Published: Hello, On a Groov Epic I’d like the strategy runs automatically on power up, with no need to press a button on HMI or with PAC control. I checked the documentation, tried to find something on the forum...moreHello, On a Groov Epic I’d like the strategy runs automatically on power up, with no need to press a button on HMI or with PAC control. I checked the documentation, tried to find something on the forum but can’t get a clear answer. Thanks for your help.... <less Having a hard time with installing Tailscale on EPIC Forum - Published: Hello, I am trying to follow this guide from Corso Systems Corso Systems Tailscale on Opto22 groov Hardware | Corso Systems Corso Systems walks through setting up...moreHello, I am trying to follow this guide from Corso Systems Corso Systems Tailscale on Opto22 groov Hardware | Corso Systems Corso Systems walks through setting up Tailscale on an Opto22 groov RIO. Tailscale is built on the Wireguard framework, but can be easier to configure depending on your IT skillset. And I keep getting this error after I do the wget https://pkgs.tailscale.com/stable/tailscale_1.62.0_arm.tgz Connecting to pkgs.tails...... <less Fail to connect node-red to websocket (postman) Forum - Published: Fail to connect node-red to websocket (postman) because of Error on self signed certificate… Groove Rio, How listen to groove value to websocket… ...Fail to connect node-red to websocket (postman) because of Error on self signed certificate… Groove Rio, How listen to groove value to websocket… ... <less PAC Controller blocking port 22001? Forum - Published: I have a system using a SNAP-PAC-R1 for I/O, using an old program (Lookout by National Instruments) and we want to start using PAC Control instead. So I made a strategy and tried to download it to the...moreI have a system using a SNAP-PAC-R1 for I/O, using an old program (Lookout by National Instruments) and we want to start using PAC Control instead. So I made a strategy and tried to download it to the controller and got an error code -10057. The Ethernet connection is definitely there; I can ping the controller (10.90.150.56) from the PC with PAC Control (10.90.150.2). Both are on the same subnet. I asked my network admin if the switches might be blocking communication through port 22001, and he...... <less Groov View plug in display refresh rate Forum - Published: I have displayed the groov View interface using the local browser on a groov EPIC controller across a company network, and used a Dell touch screen monitor plugged directly into the HDMI port and USB...moreI have displayed the groov View interface using the local browser on a groov EPIC controller across a company network, and used a Dell touch screen monitor plugged directly into the HDMI port and USB port of the groov EPIC. The HDMI connection has a refresh time from 1 to 4 seconds, and the remote browsers refresh is 1 second or less. On another tech support issue, I was told that the local browser that is used for the HDMI connection has a bug and will be updated in the next firmware release of...... <less Unable to install node-red-contrib-azure-iot-hub 0.5.3 in Groov EPIC Forum - Published: Hi, I am working on Groov EPIC PR2 and want to connect to Azure-IOT-hub because my company uses azure for streaming and visualizing sensor data. When I try to install node-red-contrib-azure-iot-hub 0.5...moreHi, I am working on Groov EPIC PR2 and want to connect to Azure-IOT-hub because my company uses azure for streaming and visualizing sensor data. When I try to install node-red-contrib-azure-iot-hub 0.5.3 i got the following error. Can someone help here on this. Error log is added here for reference. 024-03-20T08:16:17.120Z Install : @nodecolor/node-red-contrib-azure-iot-hub 0.5.3 2024-03-20T08:16:18.366Z npm install --no-audit --no-update-notifier --no-fund --save --save-prefix=~ --production --...... <less Groovepic not getting connected with Vi network Forum - Published: In India Vi is a renowned mobile service provider. When I am trying to use the hotspot through Vi network then I am unable to access groovepic at my machine. PFB the IP addresses- Hotspot’s IP address...moreIn India Vi is a renowned mobile service provider. When I am trying to use the hotspot through Vi network then I am unable to access groovepic at my machine. PFB the IP addresses- Hotspot’s IP address(at my laptop accessing this IP)-192.168.116.132 IP address to access groovepic at my laptop-192.168.137.68. When I am accessing 192.168.137.68 at chrome then it throws internet timed out error message. Please suggest as to how to access groovepic at laptop through Vi hotspot... <less Can the AS-i network be connected to the R1 controller? Forum - Published: Hello everyone, one of my customers asked me about AS-i. Can his existing AS-i network be connected to the R1 controller? If it is possible, how can I do it? What equipment needs to be added? There is...moreHello everyone, one of my customers asked me about AS-i. Can his existing AS-i network be connected to the R1 controller? If it is possible, how can I do it? What equipment needs to be added? There is an AS-i master station and more than 20 AS-i actuators and sensors. Thanks!... <less Point I/O for EPIC Forum - Published: I would like to know if there is a product that could be used as a Point I/O (like the Allen Bradley Points I/O) I am using this EPIC processor that must activate more than 30 valves that are like 30...moreI would like to know if there is a product that could be used as a Point I/O (like the Allen Bradley Points I/O) I am using this EPIC processor that must activate more than 30 valves that are like 30 feet away from the device. Another EPIC will not be the best solution. I am looking for this Point I/O so I can communicate with them through ethernet IP (or similar).... <less Is There A Limit to Context Data Storage in Node-RED? Forum - Published: I have finally found a method for passing tags from Node-RED to Ignition Edge to use in Ignition Designer, but it requires storing values as Context Data in Node-RED then calling these values in the...moreI have finally found a method for passing tags from Node-RED to Ignition Edge to use in Ignition Designer, but it requires storing values as Context Data in Node-RED then calling these values in the Address Space of an OPC-UA server node (node-red-contrib-opcua-server). However, I will eventually need to pass a much higher volume of data and I’m wondering if using this method will be an issue if there is a limit to how many values I can store as Context Data.... <less Pointer to an Up Timer Forum - Published: I’ve created a pointer table containing pointers to a series of up timers. Here’s an example of how the table values are assigned, see below. SetUpTimerTarget(60, Timer_sec); ptTimerTable[0] = &Timer...moreI’ve created a pointer table containing pointers to a series of up timers. Here’s an example of how the table values are assigned, see below. SetUpTimerTarget(60, Timer_sec); ptTimerTable[0] = &Timer_sec; I then start the time in later code, see below. StartTimer(*ptTimerTable[0]); When Test Compiling I get the following syntax error. Unable to find variable or command “*ptTimerTable[0]” What am I doing wrong here? Thanks in Advance, DKMarion... <less Can I use Ignition Node-RED module with Ignition Edge Free Trial? Forum - Published: I’m attempting to set up an API Key with the Ignition Node-RED module, but am getting an error that the license is invalid. I can’t tell if this is saying that (a) I can’t use this module with Ignition...moreI’m attempting to set up an API Key with the Ignition Node-RED module, but am getting an error that the license is invalid. I can’t tell if this is saying that (a) I can’t use this module with Ignition Edge unless I have an Ignition Edge license (and am not just using the free trial) or (b) I can’t use this module with Ignition Edge because the module license itself is invalid. image1254×213 9.61 KB Has anyone come across this?... <less PAC 10.5 Analog Input - Moving Average Forum - Published: A simple questions that I cannot find documented (or I didn’t look in the right place). The new Moving Average built into the Analog Inputs can be setup to look at X Number of Samples. What determines...moreA simple questions that I cannot find documented (or I didn’t look in the right place). The new Moving Average built into the Analog Inputs can be setup to look at X Number of Samples. What determines the rate of each sample ? A moving average of 10 samples at 1 sec is very different from a moving average of 10 samples at 100msec - both of which I’ve done in the past via logic. Is it based on every time the configuration reads the point (which may or may not be at a set time base) OR is it based...... <less Page 1 of 128Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Accessing Files Stored on Groov EPIC in Ignition Edge Forum - Published: I’m using Node-RED hosted on a Groov EPIC to read data from a serial device and write it to a CSV file (stored on the EPIC at /home/dev/secured/…). I want to pull data from the CSV file into Tags in...moreI’m using Node-RED hosted on a Groov EPIC to read data from a serial device and write it to a CSV file (stored on the EPIC at /home/dev/secured/…). I want to pull data from the CSV file into Tags in Ignition Edge (using a script in Ignition Edge). I know how the syntax on the Ignition Edge side of things works, but the function that reads the file in Ignition Edge requires me to specify a filepath. I tried both of these filepaths in the Ignition Edge script, but both yielded an error saying that...... <less Optimizing PID-Loop Forum - Published: We’ve recently deployed a PAC-R1 system using one PID-Loop as its main control algorithm to maintain a target level (set point) of dissolved ozone (O3) in a large tank of water. In this application, an...moreWe’ve recently deployed a PAC-R1 system using one PID-Loop as its main control algorithm to maintain a target level (set point) of dissolved ozone (O3) in a large tank of water. In this application, an ORP sensor is used to measure the ORP level (in mV) in the water being supplied from a large water tank, which in turn will drive an analog output to an ozone generator to control how much ozone to generate and inject into the water circulating back to the tank (Output is in the range of 0% to 10...... <less How to retrieve Binary data logged with PAC Display Forum - Published: We discovered that one of the data log files has been accidentally configured to save as a “Binary” file. We can change the PAC display to save in CSV as all other data files…however, now that there is...moreWe discovered that one of the data log files has been accidentally configured to save as a “Binary” file. We can change the PAC display to save in CSV as all other data files…however, now that there is quite a bit of data saved in binary, what is a recommended way to import this data and hopefully be able to convert it to CSV to be standard with other data? Thanks for any help, Andre... <less EPIC OPC Server integer variable as boolean not working Forum - Published: I’m having problems with using the “As Boolean” in the public access for PAC Control integers not reporting the correct value in the OPC Server. Bit seems to be working (so far). Config: image620×561 48...moreI’m having problems with using the “As Boolean” in the public access for PAC Control integers not reporting the correct value in the OPC Server. Bit seems to be working (so far). Config: image620×561 48.7 KB Value in PAC Control debug: Ignition Tag Browser (just dragged the values from the + devices list): image1063×53 8.5 KB EPIC firmware 3.5.1-b.85 PAC Control Basic 10.5... <less Groov Rio Capabilities Forum - Published: Hello, I am working on scoping how to implement Groov RIO on our manufacturing floor. We have 3 Manufacturing machines with Allen Bradley PLCs that I would like to connect to and publish some tags onto a...moreHello, I am working on scoping how to implement Groov RIO on our manufacturing floor. We have 3 Manufacturing machines with Allen Bradley PLCs that I would like to connect to and publish some tags onto a dashboard to be viewed remotely by other users on the plant network. The limitation as always is the cost, and I am trying to see what the most cost-efficient way is to see that data. I am thinking about connecting 3 Groov RIOs (one to each machine) and then install a groov server on a PC wher...... <less MQTT client from Groov EPIC node red keep getting disconnected to azure eventgrid MQTT broker Forum - Published: Hi, I am running MQTT broker in microsoft azure eventgrid and I have generated certificates and keys to connect the Grooc EPIC nodered MQTT out client to eventgrid mqtt broker. When I deploy i could see...moreHi, I am running MQTT broker in microsoft azure eventgrid and I have generated certificates and keys to connect the Grooc EPIC nodered MQTT out client to eventgrid mqtt broker. When I deploy i could see it is connected for 10 seconds. After that it got disconnected and every few seconds it is showing connecting and got disconnected again. I have followed microsoft azure eventgrid tutorials for this and they gave examples for mqttx app for testing purpose. I am not sure what I am missing here and...... <less MQTT Sparkolug B message types with MQTT Sparkplug B out Forum - Published: SparkplugB_04_2024.zip (2.4 KB) Hello. I want to create all message types with “MQTT Sparkplug B out” that would work in Ignition SCADA. NBIRTH and NDATA are working but DBIRTH is rejected and I get back...moreSparkplugB_04_2024.zip (2.4 KB) Hello. I want to create all message types with “MQTT Sparkplug B out” that would work in Ignition SCADA. NBIRTH and NDATA are working but DBIRTH is rejected and I get back Rebirth control. I believe that my DBIRTH message is In accordance with Sparkplug specifications. Does anybody know how to fix the DBIRTH message that would work in Ignition SCADA? Can somebody share the flow in Node-Red where all Sparkplug b message types would work in Ignition SCADA (It can be...... <less Node-Red Sparkplub send JSON datatype Forum - Published: I am trying to set up function to send a JSON Obect to MQTT Broker using sparkplug B. The function is: var jsonObject = msg.payload; // Convert JSON object to string var jsonString = JSON.stringify...moreI am trying to set up function to send a JSON Obect to MQTT Broker using sparkplug B. The function is: var jsonObject = msg.payload; // Convert JSON object to string var jsonString = JSON.stringify(jsonObject); var sparkplugBMessage = { “metrics”: [ { “name”:“RECIPE”, “type”:12, “value”: jsonString } ] }; // Set the stringified JSON as the new payload msg.payload = sparkplugBMessage; //msg.js=jsonObject //msg.jsstring=jsonString // Return the modified message return msg; The debug results are: i...... <less Access Control Systems Forum - Published: Is anyone using any OPTO22 product to operate an Access Control System? We would entertain Wiegland or RFID proximity cards and readers. Our application includes three walk through gates with mag locks...moreIs anyone using any OPTO22 product to operate an Access Control System? We would entertain Wiegland or RFID proximity cards and readers. Our application includes three walk through gates with mag locks and two drive through gates with chain openers. Any advice would be much appreciated. Reay... <less Pac R1 to Automation Direct C More HMI through Modbus Forum - Published: I have a snap-pac-r1w and am trying to connect it to an Automation Direct C-More HMI EA9-T15CL-R Via modbus. The HMI is the master and we have the slave subroutine running in the strategy from the...moreI have a snap-pac-r1w and am trying to connect it to an Automation Direct C-More HMI EA9-T15CL-R Via modbus. The HMI is the master and we have the slave subroutine running in the strategy from the modbus integration kit. For testing purposes we are just using the supplied strategy from the modbus integration kit. Good news: Coils and Ints work fine. Bad news: When entering a float variable on the HMI it goes into the Int holding table over two consecutive values, not to the float holding t...... <less How to start the startegy automatically on power up? Forum - Published: Hello, On a Groov Epic I’d like the strategy runs automatically on power up, with no need to press a button on HMI or with PAC control. I checked the documentation, tried to find something on the forum...moreHello, On a Groov Epic I’d like the strategy runs automatically on power up, with no need to press a button on HMI or with PAC control. I checked the documentation, tried to find something on the forum but can’t get a clear answer. Thanks for your help.... <less Having a hard time with installing Tailscale on EPIC Forum - Published: Hello, I am trying to follow this guide from Corso Systems Corso Systems Tailscale on Opto22 groov Hardware | Corso Systems Corso Systems walks through setting up...moreHello, I am trying to follow this guide from Corso Systems Corso Systems Tailscale on Opto22 groov Hardware | Corso Systems Corso Systems walks through setting up Tailscale on an Opto22 groov RIO. Tailscale is built on the Wireguard framework, but can be easier to configure depending on your IT skillset. And I keep getting this error after I do the wget https://pkgs.tailscale.com/stable/tailscale_1.62.0_arm.tgz Connecting to pkgs.tails...... <less Fail to connect node-red to websocket (postman) Forum - Published: Fail to connect node-red to websocket (postman) because of Error on self signed certificate… Groove Rio, How listen to groove value to websocket… ...Fail to connect node-red to websocket (postman) because of Error on self signed certificate… Groove Rio, How listen to groove value to websocket… ... <less PAC Controller blocking port 22001? Forum - Published: I have a system using a SNAP-PAC-R1 for I/O, using an old program (Lookout by National Instruments) and we want to start using PAC Control instead. So I made a strategy and tried to download it to the...moreI have a system using a SNAP-PAC-R1 for I/O, using an old program (Lookout by National Instruments) and we want to start using PAC Control instead. So I made a strategy and tried to download it to the controller and got an error code -10057. The Ethernet connection is definitely there; I can ping the controller (10.90.150.56) from the PC with PAC Control (10.90.150.2). Both are on the same subnet. I asked my network admin if the switches might be blocking communication through port 22001, and he...... <less Groov View plug in display refresh rate Forum - Published: I have displayed the groov View interface using the local browser on a groov EPIC controller across a company network, and used a Dell touch screen monitor plugged directly into the HDMI port and USB...moreI have displayed the groov View interface using the local browser on a groov EPIC controller across a company network, and used a Dell touch screen monitor plugged directly into the HDMI port and USB port of the groov EPIC. The HDMI connection has a refresh time from 1 to 4 seconds, and the remote browsers refresh is 1 second or less. On another tech support issue, I was told that the local browser that is used for the HDMI connection has a bug and will be updated in the next firmware release of...... <less Unable to install node-red-contrib-azure-iot-hub 0.5.3 in Groov EPIC Forum - Published: Hi, I am working on Groov EPIC PR2 and want to connect to Azure-IOT-hub because my company uses azure for streaming and visualizing sensor data. When I try to install node-red-contrib-azure-iot-hub 0.5...moreHi, I am working on Groov EPIC PR2 and want to connect to Azure-IOT-hub because my company uses azure for streaming and visualizing sensor data. When I try to install node-red-contrib-azure-iot-hub 0.5.3 i got the following error. Can someone help here on this. Error log is added here for reference. 024-03-20T08:16:17.120Z Install : @nodecolor/node-red-contrib-azure-iot-hub 0.5.3 2024-03-20T08:16:18.366Z npm install --no-audit --no-update-notifier --no-fund --save --save-prefix=~ --production --...... <less Groovepic not getting connected with Vi network Forum - Published: In India Vi is a renowned mobile service provider. When I am trying to use the hotspot through Vi network then I am unable to access groovepic at my machine. PFB the IP addresses- Hotspot’s IP address...moreIn India Vi is a renowned mobile service provider. When I am trying to use the hotspot through Vi network then I am unable to access groovepic at my machine. PFB the IP addresses- Hotspot’s IP address(at my laptop accessing this IP)-192.168.116.132 IP address to access groovepic at my laptop-192.168.137.68. When I am accessing 192.168.137.68 at chrome then it throws internet timed out error message. Please suggest as to how to access groovepic at laptop through Vi hotspot... <less Can the AS-i network be connected to the R1 controller? Forum - Published: Hello everyone, one of my customers asked me about AS-i. Can his existing AS-i network be connected to the R1 controller? If it is possible, how can I do it? What equipment needs to be added? There is...moreHello everyone, one of my customers asked me about AS-i. Can his existing AS-i network be connected to the R1 controller? If it is possible, how can I do it? What equipment needs to be added? There is an AS-i master station and more than 20 AS-i actuators and sensors. Thanks!... <less Point I/O for EPIC Forum - Published: I would like to know if there is a product that could be used as a Point I/O (like the Allen Bradley Points I/O) I am using this EPIC processor that must activate more than 30 valves that are like 30...moreI would like to know if there is a product that could be used as a Point I/O (like the Allen Bradley Points I/O) I am using this EPIC processor that must activate more than 30 valves that are like 30 feet away from the device. Another EPIC will not be the best solution. I am looking for this Point I/O so I can communicate with them through ethernet IP (or similar).... <less Is There A Limit to Context Data Storage in Node-RED? Forum - Published: I have finally found a method for passing tags from Node-RED to Ignition Edge to use in Ignition Designer, but it requires storing values as Context Data in Node-RED then calling these values in the...moreI have finally found a method for passing tags from Node-RED to Ignition Edge to use in Ignition Designer, but it requires storing values as Context Data in Node-RED then calling these values in the Address Space of an OPC-UA server node (node-red-contrib-opcua-server). However, I will eventually need to pass a much higher volume of data and I’m wondering if using this method will be an issue if there is a limit to how many values I can store as Context Data.... <less Pointer to an Up Timer Forum - Published: I’ve created a pointer table containing pointers to a series of up timers. Here’s an example of how the table values are assigned, see below. SetUpTimerTarget(60, Timer_sec); ptTimerTable[0] = &Timer...moreI’ve created a pointer table containing pointers to a series of up timers. Here’s an example of how the table values are assigned, see below. SetUpTimerTarget(60, Timer_sec); ptTimerTable[0] = &Timer_sec; I then start the time in later code, see below. StartTimer(*ptTimerTable[0]); When Test Compiling I get the following syntax error. Unable to find variable or command “*ptTimerTable[0]” What am I doing wrong here? Thanks in Advance, DKMarion... <less Can I use Ignition Node-RED module with Ignition Edge Free Trial? Forum - Published: I’m attempting to set up an API Key with the Ignition Node-RED module, but am getting an error that the license is invalid. I can’t tell if this is saying that (a) I can’t use this module with Ignition...moreI’m attempting to set up an API Key with the Ignition Node-RED module, but am getting an error that the license is invalid. I can’t tell if this is saying that (a) I can’t use this module with Ignition Edge unless I have an Ignition Edge license (and am not just using the free trial) or (b) I can’t use this module with Ignition Edge because the module license itself is invalid. image1254×213 9.61 KB Has anyone come across this?... <less PAC 10.5 Analog Input - Moving Average Forum - Published: A simple questions that I cannot find documented (or I didn’t look in the right place). The new Moving Average built into the Analog Inputs can be setup to look at X Number of Samples. What determines...moreA simple questions that I cannot find documented (or I didn’t look in the right place). The new Moving Average built into the Analog Inputs can be setup to look at X Number of Samples. What determines the rate of each sample ? A moving average of 10 samples at 1 sec is very different from a moving average of 10 samples at 100msec - both of which I’ve done in the past via logic. Is it based on every time the configuration reads the point (which may or may not be at a set time base) OR is it based...... <less Page 1 of 128Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Optimizing PID-Loop Forum - Published: We’ve recently deployed a PAC-R1 system using one PID-Loop as its main control algorithm to maintain a target level (set point) of dissolved ozone (O3) in a large tank of water. In this application, an...moreWe’ve recently deployed a PAC-R1 system using one PID-Loop as its main control algorithm to maintain a target level (set point) of dissolved ozone (O3) in a large tank of water. In this application, an ORP sensor is used to measure the ORP level (in mV) in the water being supplied from a large water tank, which in turn will drive an analog output to an ozone generator to control how much ozone to generate and inject into the water circulating back to the tank (Output is in the range of 0% to 10...... <less How to retrieve Binary data logged with PAC Display Forum - Published: We discovered that one of the data log files has been accidentally configured to save as a “Binary” file. We can change the PAC display to save in CSV as all other data files…however, now that there is...moreWe discovered that one of the data log files has been accidentally configured to save as a “Binary” file. We can change the PAC display to save in CSV as all other data files…however, now that there is quite a bit of data saved in binary, what is a recommended way to import this data and hopefully be able to convert it to CSV to be standard with other data? Thanks for any help, Andre... <less EPIC OPC Server integer variable as boolean not working Forum - Published: I’m having problems with using the “As Boolean” in the public access for PAC Control integers not reporting the correct value in the OPC Server. Bit seems to be working (so far). Config: image620×561 48...moreI’m having problems with using the “As Boolean” in the public access for PAC Control integers not reporting the correct value in the OPC Server. Bit seems to be working (so far). Config: image620×561 48.7 KB Value in PAC Control debug: Ignition Tag Browser (just dragged the values from the + devices list): image1063×53 8.5 KB EPIC firmware 3.5.1-b.85 PAC Control Basic 10.5... <less Groov Rio Capabilities Forum - Published: Hello, I am working on scoping how to implement Groov RIO on our manufacturing floor. We have 3 Manufacturing machines with Allen Bradley PLCs that I would like to connect to and publish some tags onto a...moreHello, I am working on scoping how to implement Groov RIO on our manufacturing floor. We have 3 Manufacturing machines with Allen Bradley PLCs that I would like to connect to and publish some tags onto a dashboard to be viewed remotely by other users on the plant network. The limitation as always is the cost, and I am trying to see what the most cost-efficient way is to see that data. I am thinking about connecting 3 Groov RIOs (one to each machine) and then install a groov server on a PC wher...... <less MQTT client from Groov EPIC node red keep getting disconnected to azure eventgrid MQTT broker Forum - Published: Hi, I am running MQTT broker in microsoft azure eventgrid and I have generated certificates and keys to connect the Grooc EPIC nodered MQTT out client to eventgrid mqtt broker. When I deploy i could see...moreHi, I am running MQTT broker in microsoft azure eventgrid and I have generated certificates and keys to connect the Grooc EPIC nodered MQTT out client to eventgrid mqtt broker. When I deploy i could see it is connected for 10 seconds. After that it got disconnected and every few seconds it is showing connecting and got disconnected again. I have followed microsoft azure eventgrid tutorials for this and they gave examples for mqttx app for testing purpose. I am not sure what I am missing here and...... <less MQTT Sparkolug B message types with MQTT Sparkplug B out Forum - Published: SparkplugB_04_2024.zip (2.4 KB) Hello. I want to create all message types with “MQTT Sparkplug B out” that would work in Ignition SCADA. NBIRTH and NDATA are working but DBIRTH is rejected and I get back...moreSparkplugB_04_2024.zip (2.4 KB) Hello. I want to create all message types with “MQTT Sparkplug B out” that would work in Ignition SCADA. NBIRTH and NDATA are working but DBIRTH is rejected and I get back Rebirth control. I believe that my DBIRTH message is In accordance with Sparkplug specifications. Does anybody know how to fix the DBIRTH message that would work in Ignition SCADA? Can somebody share the flow in Node-Red where all Sparkplug b message types would work in Ignition SCADA (It can be...... <less Node-Red Sparkplub send JSON datatype Forum - Published: I am trying to set up function to send a JSON Obect to MQTT Broker using sparkplug B. The function is: var jsonObject = msg.payload; // Convert JSON object to string var jsonString = JSON.stringify...moreI am trying to set up function to send a JSON Obect to MQTT Broker using sparkplug B. The function is: var jsonObject = msg.payload; // Convert JSON object to string var jsonString = JSON.stringify(jsonObject); var sparkplugBMessage = { “metrics”: [ { “name”:“RECIPE”, “type”:12, “value”: jsonString } ] }; // Set the stringified JSON as the new payload msg.payload = sparkplugBMessage; //msg.js=jsonObject //msg.jsstring=jsonString // Return the modified message return msg; The debug results are: i...... <less Access Control Systems Forum - Published: Is anyone using any OPTO22 product to operate an Access Control System? We would entertain Wiegland or RFID proximity cards and readers. Our application includes three walk through gates with mag locks...moreIs anyone using any OPTO22 product to operate an Access Control System? We would entertain Wiegland or RFID proximity cards and readers. Our application includes three walk through gates with mag locks and two drive through gates with chain openers. Any advice would be much appreciated. Reay... <less Pac R1 to Automation Direct C More HMI through Modbus Forum - Published: I have a snap-pac-r1w and am trying to connect it to an Automation Direct C-More HMI EA9-T15CL-R Via modbus. The HMI is the master and we have the slave subroutine running in the strategy from the...moreI have a snap-pac-r1w and am trying to connect it to an Automation Direct C-More HMI EA9-T15CL-R Via modbus. The HMI is the master and we have the slave subroutine running in the strategy from the modbus integration kit. For testing purposes we are just using the supplied strategy from the modbus integration kit. Good news: Coils and Ints work fine. Bad news: When entering a float variable on the HMI it goes into the Int holding table over two consecutive values, not to the float holding t...... <less How to start the startegy automatically on power up? Forum - Published: Hello, On a Groov Epic I’d like the strategy runs automatically on power up, with no need to press a button on HMI or with PAC control. I checked the documentation, tried to find something on the forum...moreHello, On a Groov Epic I’d like the strategy runs automatically on power up, with no need to press a button on HMI or with PAC control. I checked the documentation, tried to find something on the forum but can’t get a clear answer. Thanks for your help.... <less Having a hard time with installing Tailscale on EPIC Forum - Published: Hello, I am trying to follow this guide from Corso Systems Corso Systems Tailscale on Opto22 groov Hardware | Corso Systems Corso Systems walks through setting up...moreHello, I am trying to follow this guide from Corso Systems Corso Systems Tailscale on Opto22 groov Hardware | Corso Systems Corso Systems walks through setting up Tailscale on an Opto22 groov RIO. Tailscale is built on the Wireguard framework, but can be easier to configure depending on your IT skillset. And I keep getting this error after I do the wget https://pkgs.tailscale.com/stable/tailscale_1.62.0_arm.tgz Connecting to pkgs.tails...... <less Fail to connect node-red to websocket (postman) Forum - Published: Fail to connect node-red to websocket (postman) because of Error on self signed certificate… Groove Rio, How listen to groove value to websocket… ...Fail to connect node-red to websocket (postman) because of Error on self signed certificate… Groove Rio, How listen to groove value to websocket… ... <less PAC Controller blocking port 22001? Forum - Published: I have a system using a SNAP-PAC-R1 for I/O, using an old program (Lookout by National Instruments) and we want to start using PAC Control instead. So I made a strategy and tried to download it to the...moreI have a system using a SNAP-PAC-R1 for I/O, using an old program (Lookout by National Instruments) and we want to start using PAC Control instead. So I made a strategy and tried to download it to the controller and got an error code -10057. The Ethernet connection is definitely there; I can ping the controller (10.90.150.56) from the PC with PAC Control (10.90.150.2). Both are on the same subnet. I asked my network admin if the switches might be blocking communication through port 22001, and he...... <less Groov View plug in display refresh rate Forum - Published: I have displayed the groov View interface using the local browser on a groov EPIC controller across a company network, and used a Dell touch screen monitor plugged directly into the HDMI port and USB...moreI have displayed the groov View interface using the local browser on a groov EPIC controller across a company network, and used a Dell touch screen monitor plugged directly into the HDMI port and USB port of the groov EPIC. The HDMI connection has a refresh time from 1 to 4 seconds, and the remote browsers refresh is 1 second or less. On another tech support issue, I was told that the local browser that is used for the HDMI connection has a bug and will be updated in the next firmware release of...... <less Unable to install node-red-contrib-azure-iot-hub 0.5.3 in Groov EPIC Forum - Published: Hi, I am working on Groov EPIC PR2 and want to connect to Azure-IOT-hub because my company uses azure for streaming and visualizing sensor data. When I try to install node-red-contrib-azure-iot-hub 0.5...moreHi, I am working on Groov EPIC PR2 and want to connect to Azure-IOT-hub because my company uses azure for streaming and visualizing sensor data. When I try to install node-red-contrib-azure-iot-hub 0.5.3 i got the following error. Can someone help here on this. Error log is added here for reference. 024-03-20T08:16:17.120Z Install : @nodecolor/node-red-contrib-azure-iot-hub 0.5.3 2024-03-20T08:16:18.366Z npm install --no-audit --no-update-notifier --no-fund --save --save-prefix=~ --production --...... <less Groovepic not getting connected with Vi network Forum - Published: In India Vi is a renowned mobile service provider. When I am trying to use the hotspot through Vi network then I am unable to access groovepic at my machine. PFB the IP addresses- Hotspot’s IP address...moreIn India Vi is a renowned mobile service provider. When I am trying to use the hotspot through Vi network then I am unable to access groovepic at my machine. PFB the IP addresses- Hotspot’s IP address(at my laptop accessing this IP)-192.168.116.132 IP address to access groovepic at my laptop-192.168.137.68. When I am accessing 192.168.137.68 at chrome then it throws internet timed out error message. Please suggest as to how to access groovepic at laptop through Vi hotspot... <less Can the AS-i network be connected to the R1 controller? Forum - Published: Hello everyone, one of my customers asked me about AS-i. Can his existing AS-i network be connected to the R1 controller? If it is possible, how can I do it? What equipment needs to be added? There is...moreHello everyone, one of my customers asked me about AS-i. Can his existing AS-i network be connected to the R1 controller? If it is possible, how can I do it? What equipment needs to be added? There is an AS-i master station and more than 20 AS-i actuators and sensors. Thanks!... <less Point I/O for EPIC Forum - Published: I would like to know if there is a product that could be used as a Point I/O (like the Allen Bradley Points I/O) I am using this EPIC processor that must activate more than 30 valves that are like 30...moreI would like to know if there is a product that could be used as a Point I/O (like the Allen Bradley Points I/O) I am using this EPIC processor that must activate more than 30 valves that are like 30 feet away from the device. Another EPIC will not be the best solution. I am looking for this Point I/O so I can communicate with them through ethernet IP (or similar).... <less Is There A Limit to Context Data Storage in Node-RED? Forum - Published: I have finally found a method for passing tags from Node-RED to Ignition Edge to use in Ignition Designer, but it requires storing values as Context Data in Node-RED then calling these values in the...moreI have finally found a method for passing tags from Node-RED to Ignition Edge to use in Ignition Designer, but it requires storing values as Context Data in Node-RED then calling these values in the Address Space of an OPC-UA server node (node-red-contrib-opcua-server). However, I will eventually need to pass a much higher volume of data and I’m wondering if using this method will be an issue if there is a limit to how many values I can store as Context Data.... <less Pointer to an Up Timer Forum - Published: I’ve created a pointer table containing pointers to a series of up timers. Here’s an example of how the table values are assigned, see below. SetUpTimerTarget(60, Timer_sec); ptTimerTable[0] = &Timer...moreI’ve created a pointer table containing pointers to a series of up timers. Here’s an example of how the table values are assigned, see below. SetUpTimerTarget(60, Timer_sec); ptTimerTable[0] = &Timer_sec; I then start the time in later code, see below. StartTimer(*ptTimerTable[0]); When Test Compiling I get the following syntax error. Unable to find variable or command “*ptTimerTable[0]” What am I doing wrong here? Thanks in Advance, DKMarion... <less Can I use Ignition Node-RED module with Ignition Edge Free Trial? Forum - Published: I’m attempting to set up an API Key with the Ignition Node-RED module, but am getting an error that the license is invalid. I can’t tell if this is saying that (a) I can’t use this module with Ignition...moreI’m attempting to set up an API Key with the Ignition Node-RED module, but am getting an error that the license is invalid. I can’t tell if this is saying that (a) I can’t use this module with Ignition Edge unless I have an Ignition Edge license (and am not just using the free trial) or (b) I can’t use this module with Ignition Edge because the module license itself is invalid. image1254×213 9.61 KB Has anyone come across this?... <less PAC 10.5 Analog Input - Moving Average Forum - Published: A simple questions that I cannot find documented (or I didn’t look in the right place). The new Moving Average built into the Analog Inputs can be setup to look at X Number of Samples. What determines...moreA simple questions that I cannot find documented (or I didn’t look in the right place). The new Moving Average built into the Analog Inputs can be setup to look at X Number of Samples. What determines the rate of each sample ? A moving average of 10 samples at 1 sec is very different from a moving average of 10 samples at 100msec - both of which I’ve done in the past via logic. Is it based on every time the configuration reads the point (which may or may not be at a set time base) OR is it based...... <less Page 1 of 128Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
How to retrieve Binary data logged with PAC Display Forum - Published: We discovered that one of the data log files has been accidentally configured to save as a “Binary” file. We can change the PAC display to save in CSV as all other data files…however, now that there is...moreWe discovered that one of the data log files has been accidentally configured to save as a “Binary” file. We can change the PAC display to save in CSV as all other data files…however, now that there is quite a bit of data saved in binary, what is a recommended way to import this data and hopefully be able to convert it to CSV to be standard with other data? Thanks for any help, Andre... <less EPIC OPC Server integer variable as boolean not working Forum - Published: I’m having problems with using the “As Boolean” in the public access for PAC Control integers not reporting the correct value in the OPC Server. Bit seems to be working (so far). Config: image620×561 48...moreI’m having problems with using the “As Boolean” in the public access for PAC Control integers not reporting the correct value in the OPC Server. Bit seems to be working (so far). Config: image620×561 48.7 KB Value in PAC Control debug: Ignition Tag Browser (just dragged the values from the + devices list): image1063×53 8.5 KB EPIC firmware 3.5.1-b.85 PAC Control Basic 10.5... <less Groov Rio Capabilities Forum - Published: Hello, I am working on scoping how to implement Groov RIO on our manufacturing floor. We have 3 Manufacturing machines with Allen Bradley PLCs that I would like to connect to and publish some tags onto a...moreHello, I am working on scoping how to implement Groov RIO on our manufacturing floor. We have 3 Manufacturing machines with Allen Bradley PLCs that I would like to connect to and publish some tags onto a dashboard to be viewed remotely by other users on the plant network. The limitation as always is the cost, and I am trying to see what the most cost-efficient way is to see that data. I am thinking about connecting 3 Groov RIOs (one to each machine) and then install a groov server on a PC wher...... <less MQTT client from Groov EPIC node red keep getting disconnected to azure eventgrid MQTT broker Forum - Published: Hi, I am running MQTT broker in microsoft azure eventgrid and I have generated certificates and keys to connect the Grooc EPIC nodered MQTT out client to eventgrid mqtt broker. When I deploy i could see...moreHi, I am running MQTT broker in microsoft azure eventgrid and I have generated certificates and keys to connect the Grooc EPIC nodered MQTT out client to eventgrid mqtt broker. When I deploy i could see it is connected for 10 seconds. After that it got disconnected and every few seconds it is showing connecting and got disconnected again. I have followed microsoft azure eventgrid tutorials for this and they gave examples for mqttx app for testing purpose. I am not sure what I am missing here and...... <less MQTT Sparkolug B message types with MQTT Sparkplug B out Forum - Published: SparkplugB_04_2024.zip (2.4 KB) Hello. I want to create all message types with “MQTT Sparkplug B out” that would work in Ignition SCADA. NBIRTH and NDATA are working but DBIRTH is rejected and I get back...moreSparkplugB_04_2024.zip (2.4 KB) Hello. I want to create all message types with “MQTT Sparkplug B out” that would work in Ignition SCADA. NBIRTH and NDATA are working but DBIRTH is rejected and I get back Rebirth control. I believe that my DBIRTH message is In accordance with Sparkplug specifications. Does anybody know how to fix the DBIRTH message that would work in Ignition SCADA? Can somebody share the flow in Node-Red where all Sparkplug b message types would work in Ignition SCADA (It can be...... <less Node-Red Sparkplub send JSON datatype Forum - Published: I am trying to set up function to send a JSON Obect to MQTT Broker using sparkplug B. The function is: var jsonObject = msg.payload; // Convert JSON object to string var jsonString = JSON.stringify...moreI am trying to set up function to send a JSON Obect to MQTT Broker using sparkplug B. The function is: var jsonObject = msg.payload; // Convert JSON object to string var jsonString = JSON.stringify(jsonObject); var sparkplugBMessage = { “metrics”: [ { “name”:“RECIPE”, “type”:12, “value”: jsonString } ] }; // Set the stringified JSON as the new payload msg.payload = sparkplugBMessage; //msg.js=jsonObject //msg.jsstring=jsonString // Return the modified message return msg; The debug results are: i...... <less Access Control Systems Forum - Published: Is anyone using any OPTO22 product to operate an Access Control System? We would entertain Wiegland or RFID proximity cards and readers. Our application includes three walk through gates with mag locks...moreIs anyone using any OPTO22 product to operate an Access Control System? We would entertain Wiegland or RFID proximity cards and readers. Our application includes three walk through gates with mag locks and two drive through gates with chain openers. Any advice would be much appreciated. Reay... <less Pac R1 to Automation Direct C More HMI through Modbus Forum - Published: I have a snap-pac-r1w and am trying to connect it to an Automation Direct C-More HMI EA9-T15CL-R Via modbus. The HMI is the master and we have the slave subroutine running in the strategy from the...moreI have a snap-pac-r1w and am trying to connect it to an Automation Direct C-More HMI EA9-T15CL-R Via modbus. The HMI is the master and we have the slave subroutine running in the strategy from the modbus integration kit. For testing purposes we are just using the supplied strategy from the modbus integration kit. Good news: Coils and Ints work fine. Bad news: When entering a float variable on the HMI it goes into the Int holding table over two consecutive values, not to the float holding t...... <less How to start the startegy automatically on power up? Forum - Published: Hello, On a Groov Epic I’d like the strategy runs automatically on power up, with no need to press a button on HMI or with PAC control. I checked the documentation, tried to find something on the forum...moreHello, On a Groov Epic I’d like the strategy runs automatically on power up, with no need to press a button on HMI or with PAC control. I checked the documentation, tried to find something on the forum but can’t get a clear answer. Thanks for your help.... <less Having a hard time with installing Tailscale on EPIC Forum - Published: Hello, I am trying to follow this guide from Corso Systems Corso Systems Tailscale on Opto22 groov Hardware | Corso Systems Corso Systems walks through setting up...moreHello, I am trying to follow this guide from Corso Systems Corso Systems Tailscale on Opto22 groov Hardware | Corso Systems Corso Systems walks through setting up Tailscale on an Opto22 groov RIO. Tailscale is built on the Wireguard framework, but can be easier to configure depending on your IT skillset. And I keep getting this error after I do the wget https://pkgs.tailscale.com/stable/tailscale_1.62.0_arm.tgz Connecting to pkgs.tails...... <less Fail to connect node-red to websocket (postman) Forum - Published: Fail to connect node-red to websocket (postman) because of Error on self signed certificate… Groove Rio, How listen to groove value to websocket… ...Fail to connect node-red to websocket (postman) because of Error on self signed certificate… Groove Rio, How listen to groove value to websocket… ... <less PAC Controller blocking port 22001? Forum - Published: I have a system using a SNAP-PAC-R1 for I/O, using an old program (Lookout by National Instruments) and we want to start using PAC Control instead. So I made a strategy and tried to download it to the...moreI have a system using a SNAP-PAC-R1 for I/O, using an old program (Lookout by National Instruments) and we want to start using PAC Control instead. So I made a strategy and tried to download it to the controller and got an error code -10057. The Ethernet connection is definitely there; I can ping the controller (10.90.150.56) from the PC with PAC Control (10.90.150.2). Both are on the same subnet. I asked my network admin if the switches might be blocking communication through port 22001, and he...... <less Groov View plug in display refresh rate Forum - Published: I have displayed the groov View interface using the local browser on a groov EPIC controller across a company network, and used a Dell touch screen monitor plugged directly into the HDMI port and USB...moreI have displayed the groov View interface using the local browser on a groov EPIC controller across a company network, and used a Dell touch screen monitor plugged directly into the HDMI port and USB port of the groov EPIC. The HDMI connection has a refresh time from 1 to 4 seconds, and the remote browsers refresh is 1 second or less. On another tech support issue, I was told that the local browser that is used for the HDMI connection has a bug and will be updated in the next firmware release of...... <less Unable to install node-red-contrib-azure-iot-hub 0.5.3 in Groov EPIC Forum - Published: Hi, I am working on Groov EPIC PR2 and want to connect to Azure-IOT-hub because my company uses azure for streaming and visualizing sensor data. When I try to install node-red-contrib-azure-iot-hub 0.5...moreHi, I am working on Groov EPIC PR2 and want to connect to Azure-IOT-hub because my company uses azure for streaming and visualizing sensor data. When I try to install node-red-contrib-azure-iot-hub 0.5.3 i got the following error. Can someone help here on this. Error log is added here for reference. 024-03-20T08:16:17.120Z Install : @nodecolor/node-red-contrib-azure-iot-hub 0.5.3 2024-03-20T08:16:18.366Z npm install --no-audit --no-update-notifier --no-fund --save --save-prefix=~ --production --...... <less Groovepic not getting connected with Vi network Forum - Published: In India Vi is a renowned mobile service provider. When I am trying to use the hotspot through Vi network then I am unable to access groovepic at my machine. PFB the IP addresses- Hotspot’s IP address...moreIn India Vi is a renowned mobile service provider. When I am trying to use the hotspot through Vi network then I am unable to access groovepic at my machine. PFB the IP addresses- Hotspot’s IP address(at my laptop accessing this IP)-192.168.116.132 IP address to access groovepic at my laptop-192.168.137.68. When I am accessing 192.168.137.68 at chrome then it throws internet timed out error message. Please suggest as to how to access groovepic at laptop through Vi hotspot... <less Can the AS-i network be connected to the R1 controller? Forum - Published: Hello everyone, one of my customers asked me about AS-i. Can his existing AS-i network be connected to the R1 controller? If it is possible, how can I do it? What equipment needs to be added? There is...moreHello everyone, one of my customers asked me about AS-i. Can his existing AS-i network be connected to the R1 controller? If it is possible, how can I do it? What equipment needs to be added? There is an AS-i master station and more than 20 AS-i actuators and sensors. Thanks!... <less Point I/O for EPIC Forum - Published: I would like to know if there is a product that could be used as a Point I/O (like the Allen Bradley Points I/O) I am using this EPIC processor that must activate more than 30 valves that are like 30...moreI would like to know if there is a product that could be used as a Point I/O (like the Allen Bradley Points I/O) I am using this EPIC processor that must activate more than 30 valves that are like 30 feet away from the device. Another EPIC will not be the best solution. I am looking for this Point I/O so I can communicate with them through ethernet IP (or similar).... <less Is There A Limit to Context Data Storage in Node-RED? Forum - Published: I have finally found a method for passing tags from Node-RED to Ignition Edge to use in Ignition Designer, but it requires storing values as Context Data in Node-RED then calling these values in the...moreI have finally found a method for passing tags from Node-RED to Ignition Edge to use in Ignition Designer, but it requires storing values as Context Data in Node-RED then calling these values in the Address Space of an OPC-UA server node (node-red-contrib-opcua-server). However, I will eventually need to pass a much higher volume of data and I’m wondering if using this method will be an issue if there is a limit to how many values I can store as Context Data.... <less Pointer to an Up Timer Forum - Published: I’ve created a pointer table containing pointers to a series of up timers. Here’s an example of how the table values are assigned, see below. SetUpTimerTarget(60, Timer_sec); ptTimerTable[0] = &Timer...moreI’ve created a pointer table containing pointers to a series of up timers. Here’s an example of how the table values are assigned, see below. SetUpTimerTarget(60, Timer_sec); ptTimerTable[0] = &Timer_sec; I then start the time in later code, see below. StartTimer(*ptTimerTable[0]); When Test Compiling I get the following syntax error. Unable to find variable or command “*ptTimerTable[0]” What am I doing wrong here? Thanks in Advance, DKMarion... <less Can I use Ignition Node-RED module with Ignition Edge Free Trial? Forum - Published: I’m attempting to set up an API Key with the Ignition Node-RED module, but am getting an error that the license is invalid. I can’t tell if this is saying that (a) I can’t use this module with Ignition...moreI’m attempting to set up an API Key with the Ignition Node-RED module, but am getting an error that the license is invalid. I can’t tell if this is saying that (a) I can’t use this module with Ignition Edge unless I have an Ignition Edge license (and am not just using the free trial) or (b) I can’t use this module with Ignition Edge because the module license itself is invalid. image1254×213 9.61 KB Has anyone come across this?... <less PAC 10.5 Analog Input - Moving Average Forum - Published: A simple questions that I cannot find documented (or I didn’t look in the right place). The new Moving Average built into the Analog Inputs can be setup to look at X Number of Samples. What determines...moreA simple questions that I cannot find documented (or I didn’t look in the right place). The new Moving Average built into the Analog Inputs can be setup to look at X Number of Samples. What determines the rate of each sample ? A moving average of 10 samples at 1 sec is very different from a moving average of 10 samples at 100msec - both of which I’ve done in the past via logic. Is it based on every time the configuration reads the point (which may or may not be at a set time base) OR is it based...... <less Page 1 of 128Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
EPIC OPC Server integer variable as boolean not working Forum - Published: I’m having problems with using the “As Boolean” in the public access for PAC Control integers not reporting the correct value in the OPC Server. Bit seems to be working (so far). Config: image620×561 48...moreI’m having problems with using the “As Boolean” in the public access for PAC Control integers not reporting the correct value in the OPC Server. Bit seems to be working (so far). Config: image620×561 48.7 KB Value in PAC Control debug: Ignition Tag Browser (just dragged the values from the + devices list): image1063×53 8.5 KB EPIC firmware 3.5.1-b.85 PAC Control Basic 10.5... <less Groov Rio Capabilities Forum - Published: Hello, I am working on scoping how to implement Groov RIO on our manufacturing floor. We have 3 Manufacturing machines with Allen Bradley PLCs that I would like to connect to and publish some tags onto a...moreHello, I am working on scoping how to implement Groov RIO on our manufacturing floor. We have 3 Manufacturing machines with Allen Bradley PLCs that I would like to connect to and publish some tags onto a dashboard to be viewed remotely by other users on the plant network. The limitation as always is the cost, and I am trying to see what the most cost-efficient way is to see that data. I am thinking about connecting 3 Groov RIOs (one to each machine) and then install a groov server on a PC wher...... <less MQTT client from Groov EPIC node red keep getting disconnected to azure eventgrid MQTT broker Forum - Published: Hi, I am running MQTT broker in microsoft azure eventgrid and I have generated certificates and keys to connect the Grooc EPIC nodered MQTT out client to eventgrid mqtt broker. When I deploy i could see...moreHi, I am running MQTT broker in microsoft azure eventgrid and I have generated certificates and keys to connect the Grooc EPIC nodered MQTT out client to eventgrid mqtt broker. When I deploy i could see it is connected for 10 seconds. After that it got disconnected and every few seconds it is showing connecting and got disconnected again. I have followed microsoft azure eventgrid tutorials for this and they gave examples for mqttx app for testing purpose. I am not sure what I am missing here and...... <less MQTT Sparkolug B message types with MQTT Sparkplug B out Forum - Published: SparkplugB_04_2024.zip (2.4 KB) Hello. I want to create all message types with “MQTT Sparkplug B out” that would work in Ignition SCADA. NBIRTH and NDATA are working but DBIRTH is rejected and I get back...moreSparkplugB_04_2024.zip (2.4 KB) Hello. I want to create all message types with “MQTT Sparkplug B out” that would work in Ignition SCADA. NBIRTH and NDATA are working but DBIRTH is rejected and I get back Rebirth control. I believe that my DBIRTH message is In accordance with Sparkplug specifications. Does anybody know how to fix the DBIRTH message that would work in Ignition SCADA? Can somebody share the flow in Node-Red where all Sparkplug b message types would work in Ignition SCADA (It can be...... <less Node-Red Sparkplub send JSON datatype Forum - Published: I am trying to set up function to send a JSON Obect to MQTT Broker using sparkplug B. The function is: var jsonObject = msg.payload; // Convert JSON object to string var jsonString = JSON.stringify...moreI am trying to set up function to send a JSON Obect to MQTT Broker using sparkplug B. The function is: var jsonObject = msg.payload; // Convert JSON object to string var jsonString = JSON.stringify(jsonObject); var sparkplugBMessage = { “metrics”: [ { “name”:“RECIPE”, “type”:12, “value”: jsonString } ] }; // Set the stringified JSON as the new payload msg.payload = sparkplugBMessage; //msg.js=jsonObject //msg.jsstring=jsonString // Return the modified message return msg; The debug results are: i...... <less Access Control Systems Forum - Published: Is anyone using any OPTO22 product to operate an Access Control System? We would entertain Wiegland or RFID proximity cards and readers. Our application includes three walk through gates with mag locks...moreIs anyone using any OPTO22 product to operate an Access Control System? We would entertain Wiegland or RFID proximity cards and readers. Our application includes three walk through gates with mag locks and two drive through gates with chain openers. Any advice would be much appreciated. Reay... <less Pac R1 to Automation Direct C More HMI through Modbus Forum - Published: I have a snap-pac-r1w and am trying to connect it to an Automation Direct C-More HMI EA9-T15CL-R Via modbus. The HMI is the master and we have the slave subroutine running in the strategy from the...moreI have a snap-pac-r1w and am trying to connect it to an Automation Direct C-More HMI EA9-T15CL-R Via modbus. The HMI is the master and we have the slave subroutine running in the strategy from the modbus integration kit. For testing purposes we are just using the supplied strategy from the modbus integration kit. Good news: Coils and Ints work fine. Bad news: When entering a float variable on the HMI it goes into the Int holding table over two consecutive values, not to the float holding t...... <less How to start the startegy automatically on power up? Forum - Published: Hello, On a Groov Epic I’d like the strategy runs automatically on power up, with no need to press a button on HMI or with PAC control. I checked the documentation, tried to find something on the forum...moreHello, On a Groov Epic I’d like the strategy runs automatically on power up, with no need to press a button on HMI or with PAC control. I checked the documentation, tried to find something on the forum but can’t get a clear answer. Thanks for your help.... <less Having a hard time with installing Tailscale on EPIC Forum - Published: Hello, I am trying to follow this guide from Corso Systems Corso Systems Tailscale on Opto22 groov Hardware | Corso Systems Corso Systems walks through setting up...moreHello, I am trying to follow this guide from Corso Systems Corso Systems Tailscale on Opto22 groov Hardware | Corso Systems Corso Systems walks through setting up Tailscale on an Opto22 groov RIO. Tailscale is built on the Wireguard framework, but can be easier to configure depending on your IT skillset. And I keep getting this error after I do the wget https://pkgs.tailscale.com/stable/tailscale_1.62.0_arm.tgz Connecting to pkgs.tails...... <less Fail to connect node-red to websocket (postman) Forum - Published: Fail to connect node-red to websocket (postman) because of Error on self signed certificate… Groove Rio, How listen to groove value to websocket… ...Fail to connect node-red to websocket (postman) because of Error on self signed certificate… Groove Rio, How listen to groove value to websocket… ... <less PAC Controller blocking port 22001? Forum - Published: I have a system using a SNAP-PAC-R1 for I/O, using an old program (Lookout by National Instruments) and we want to start using PAC Control instead. So I made a strategy and tried to download it to the...moreI have a system using a SNAP-PAC-R1 for I/O, using an old program (Lookout by National Instruments) and we want to start using PAC Control instead. So I made a strategy and tried to download it to the controller and got an error code -10057. The Ethernet connection is definitely there; I can ping the controller (10.90.150.56) from the PC with PAC Control (10.90.150.2). Both are on the same subnet. I asked my network admin if the switches might be blocking communication through port 22001, and he...... <less Groov View plug in display refresh rate Forum - Published: I have displayed the groov View interface using the local browser on a groov EPIC controller across a company network, and used a Dell touch screen monitor plugged directly into the HDMI port and USB...moreI have displayed the groov View interface using the local browser on a groov EPIC controller across a company network, and used a Dell touch screen monitor plugged directly into the HDMI port and USB port of the groov EPIC. The HDMI connection has a refresh time from 1 to 4 seconds, and the remote browsers refresh is 1 second or less. On another tech support issue, I was told that the local browser that is used for the HDMI connection has a bug and will be updated in the next firmware release of...... <less Unable to install node-red-contrib-azure-iot-hub 0.5.3 in Groov EPIC Forum - Published: Hi, I am working on Groov EPIC PR2 and want to connect to Azure-IOT-hub because my company uses azure for streaming and visualizing sensor data. When I try to install node-red-contrib-azure-iot-hub 0.5...moreHi, I am working on Groov EPIC PR2 and want to connect to Azure-IOT-hub because my company uses azure for streaming and visualizing sensor data. When I try to install node-red-contrib-azure-iot-hub 0.5.3 i got the following error. Can someone help here on this. Error log is added here for reference. 024-03-20T08:16:17.120Z Install : @nodecolor/node-red-contrib-azure-iot-hub 0.5.3 2024-03-20T08:16:18.366Z npm install --no-audit --no-update-notifier --no-fund --save --save-prefix=~ --production --...... <less Groovepic not getting connected with Vi network Forum - Published: In India Vi is a renowned mobile service provider. When I am trying to use the hotspot through Vi network then I am unable to access groovepic at my machine. PFB the IP addresses- Hotspot’s IP address...moreIn India Vi is a renowned mobile service provider. When I am trying to use the hotspot through Vi network then I am unable to access groovepic at my machine. PFB the IP addresses- Hotspot’s IP address(at my laptop accessing this IP)-192.168.116.132 IP address to access groovepic at my laptop-192.168.137.68. When I am accessing 192.168.137.68 at chrome then it throws internet timed out error message. Please suggest as to how to access groovepic at laptop through Vi hotspot... <less Can the AS-i network be connected to the R1 controller? Forum - Published: Hello everyone, one of my customers asked me about AS-i. Can his existing AS-i network be connected to the R1 controller? If it is possible, how can I do it? What equipment needs to be added? There is...moreHello everyone, one of my customers asked me about AS-i. Can his existing AS-i network be connected to the R1 controller? If it is possible, how can I do it? What equipment needs to be added? There is an AS-i master station and more than 20 AS-i actuators and sensors. Thanks!... <less Point I/O for EPIC Forum - Published: I would like to know if there is a product that could be used as a Point I/O (like the Allen Bradley Points I/O) I am using this EPIC processor that must activate more than 30 valves that are like 30...moreI would like to know if there is a product that could be used as a Point I/O (like the Allen Bradley Points I/O) I am using this EPIC processor that must activate more than 30 valves that are like 30 feet away from the device. Another EPIC will not be the best solution. I am looking for this Point I/O so I can communicate with them through ethernet IP (or similar).... <less Is There A Limit to Context Data Storage in Node-RED? Forum - Published: I have finally found a method for passing tags from Node-RED to Ignition Edge to use in Ignition Designer, but it requires storing values as Context Data in Node-RED then calling these values in the...moreI have finally found a method for passing tags from Node-RED to Ignition Edge to use in Ignition Designer, but it requires storing values as Context Data in Node-RED then calling these values in the Address Space of an OPC-UA server node (node-red-contrib-opcua-server). However, I will eventually need to pass a much higher volume of data and I’m wondering if using this method will be an issue if there is a limit to how many values I can store as Context Data.... <less Pointer to an Up Timer Forum - Published: I’ve created a pointer table containing pointers to a series of up timers. Here’s an example of how the table values are assigned, see below. SetUpTimerTarget(60, Timer_sec); ptTimerTable[0] = &Timer...moreI’ve created a pointer table containing pointers to a series of up timers. Here’s an example of how the table values are assigned, see below. SetUpTimerTarget(60, Timer_sec); ptTimerTable[0] = &Timer_sec; I then start the time in later code, see below. StartTimer(*ptTimerTable[0]); When Test Compiling I get the following syntax error. Unable to find variable or command “*ptTimerTable[0]” What am I doing wrong here? Thanks in Advance, DKMarion... <less Can I use Ignition Node-RED module with Ignition Edge Free Trial? Forum - Published: I’m attempting to set up an API Key with the Ignition Node-RED module, but am getting an error that the license is invalid. I can’t tell if this is saying that (a) I can’t use this module with Ignition...moreI’m attempting to set up an API Key with the Ignition Node-RED module, but am getting an error that the license is invalid. I can’t tell if this is saying that (a) I can’t use this module with Ignition Edge unless I have an Ignition Edge license (and am not just using the free trial) or (b) I can’t use this module with Ignition Edge because the module license itself is invalid. image1254×213 9.61 KB Has anyone come across this?... <less PAC 10.5 Analog Input - Moving Average Forum - Published: A simple questions that I cannot find documented (or I didn’t look in the right place). The new Moving Average built into the Analog Inputs can be setup to look at X Number of Samples. What determines...moreA simple questions that I cannot find documented (or I didn’t look in the right place). The new Moving Average built into the Analog Inputs can be setup to look at X Number of Samples. What determines the rate of each sample ? A moving average of 10 samples at 1 sec is very different from a moving average of 10 samples at 100msec - both of which I’ve done in the past via logic. Is it based on every time the configuration reads the point (which may or may not be at a set time base) OR is it based...... <less Page 1 of 128Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Groov Rio Capabilities Forum - Published: Hello, I am working on scoping how to implement Groov RIO on our manufacturing floor. We have 3 Manufacturing machines with Allen Bradley PLCs that I would like to connect to and publish some tags onto a...moreHello, I am working on scoping how to implement Groov RIO on our manufacturing floor. We have 3 Manufacturing machines with Allen Bradley PLCs that I would like to connect to and publish some tags onto a dashboard to be viewed remotely by other users on the plant network. The limitation as always is the cost, and I am trying to see what the most cost-efficient way is to see that data. I am thinking about connecting 3 Groov RIOs (one to each machine) and then install a groov server on a PC wher...... <less MQTT client from Groov EPIC node red keep getting disconnected to azure eventgrid MQTT broker Forum - Published: Hi, I am running MQTT broker in microsoft azure eventgrid and I have generated certificates and keys to connect the Grooc EPIC nodered MQTT out client to eventgrid mqtt broker. When I deploy i could see...moreHi, I am running MQTT broker in microsoft azure eventgrid and I have generated certificates and keys to connect the Grooc EPIC nodered MQTT out client to eventgrid mqtt broker. When I deploy i could see it is connected for 10 seconds. After that it got disconnected and every few seconds it is showing connecting and got disconnected again. I have followed microsoft azure eventgrid tutorials for this and they gave examples for mqttx app for testing purpose. I am not sure what I am missing here and...... <less MQTT Sparkolug B message types with MQTT Sparkplug B out Forum - Published: SparkplugB_04_2024.zip (2.4 KB) Hello. I want to create all message types with “MQTT Sparkplug B out” that would work in Ignition SCADA. NBIRTH and NDATA are working but DBIRTH is rejected and I get back...moreSparkplugB_04_2024.zip (2.4 KB) Hello. I want to create all message types with “MQTT Sparkplug B out” that would work in Ignition SCADA. NBIRTH and NDATA are working but DBIRTH is rejected and I get back Rebirth control. I believe that my DBIRTH message is In accordance with Sparkplug specifications. Does anybody know how to fix the DBIRTH message that would work in Ignition SCADA? Can somebody share the flow in Node-Red where all Sparkplug b message types would work in Ignition SCADA (It can be...... <less Node-Red Sparkplub send JSON datatype Forum - Published: I am trying to set up function to send a JSON Obect to MQTT Broker using sparkplug B. The function is: var jsonObject = msg.payload; // Convert JSON object to string var jsonString = JSON.stringify...moreI am trying to set up function to send a JSON Obect to MQTT Broker using sparkplug B. The function is: var jsonObject = msg.payload; // Convert JSON object to string var jsonString = JSON.stringify(jsonObject); var sparkplugBMessage = { “metrics”: [ { “name”:“RECIPE”, “type”:12, “value”: jsonString } ] }; // Set the stringified JSON as the new payload msg.payload = sparkplugBMessage; //msg.js=jsonObject //msg.jsstring=jsonString // Return the modified message return msg; The debug results are: i...... <less Access Control Systems Forum - Published: Is anyone using any OPTO22 product to operate an Access Control System? We would entertain Wiegland or RFID proximity cards and readers. Our application includes three walk through gates with mag locks...moreIs anyone using any OPTO22 product to operate an Access Control System? We would entertain Wiegland or RFID proximity cards and readers. Our application includes three walk through gates with mag locks and two drive through gates with chain openers. Any advice would be much appreciated. Reay... <less Pac R1 to Automation Direct C More HMI through Modbus Forum - Published: I have a snap-pac-r1w and am trying to connect it to an Automation Direct C-More HMI EA9-T15CL-R Via modbus. The HMI is the master and we have the slave subroutine running in the strategy from the...moreI have a snap-pac-r1w and am trying to connect it to an Automation Direct C-More HMI EA9-T15CL-R Via modbus. The HMI is the master and we have the slave subroutine running in the strategy from the modbus integration kit. For testing purposes we are just using the supplied strategy from the modbus integration kit. Good news: Coils and Ints work fine. Bad news: When entering a float variable on the HMI it goes into the Int holding table over two consecutive values, not to the float holding t...... <less How to start the startegy automatically on power up? Forum - Published: Hello, On a Groov Epic I’d like the strategy runs automatically on power up, with no need to press a button on HMI or with PAC control. I checked the documentation, tried to find something on the forum...moreHello, On a Groov Epic I’d like the strategy runs automatically on power up, with no need to press a button on HMI or with PAC control. I checked the documentation, tried to find something on the forum but can’t get a clear answer. Thanks for your help.... <less Having a hard time with installing Tailscale on EPIC Forum - Published: Hello, I am trying to follow this guide from Corso Systems Corso Systems Tailscale on Opto22 groov Hardware | Corso Systems Corso Systems walks through setting up...moreHello, I am trying to follow this guide from Corso Systems Corso Systems Tailscale on Opto22 groov Hardware | Corso Systems Corso Systems walks through setting up Tailscale on an Opto22 groov RIO. Tailscale is built on the Wireguard framework, but can be easier to configure depending on your IT skillset. And I keep getting this error after I do the wget https://pkgs.tailscale.com/stable/tailscale_1.62.0_arm.tgz Connecting to pkgs.tails...... <less Fail to connect node-red to websocket (postman) Forum - Published: Fail to connect node-red to websocket (postman) because of Error on self signed certificate… Groove Rio, How listen to groove value to websocket… ...Fail to connect node-red to websocket (postman) because of Error on self signed certificate… Groove Rio, How listen to groove value to websocket… ... <less PAC Controller blocking port 22001? Forum - Published: I have a system using a SNAP-PAC-R1 for I/O, using an old program (Lookout by National Instruments) and we want to start using PAC Control instead. So I made a strategy and tried to download it to the...moreI have a system using a SNAP-PAC-R1 for I/O, using an old program (Lookout by National Instruments) and we want to start using PAC Control instead. So I made a strategy and tried to download it to the controller and got an error code -10057. The Ethernet connection is definitely there; I can ping the controller (10.90.150.56) from the PC with PAC Control (10.90.150.2). Both are on the same subnet. I asked my network admin if the switches might be blocking communication through port 22001, and he...... <less Groov View plug in display refresh rate Forum - Published: I have displayed the groov View interface using the local browser on a groov EPIC controller across a company network, and used a Dell touch screen monitor plugged directly into the HDMI port and USB...moreI have displayed the groov View interface using the local browser on a groov EPIC controller across a company network, and used a Dell touch screen monitor plugged directly into the HDMI port and USB port of the groov EPIC. The HDMI connection has a refresh time from 1 to 4 seconds, and the remote browsers refresh is 1 second or less. On another tech support issue, I was told that the local browser that is used for the HDMI connection has a bug and will be updated in the next firmware release of...... <less Unable to install node-red-contrib-azure-iot-hub 0.5.3 in Groov EPIC Forum - Published: Hi, I am working on Groov EPIC PR2 and want to connect to Azure-IOT-hub because my company uses azure for streaming and visualizing sensor data. When I try to install node-red-contrib-azure-iot-hub 0.5...moreHi, I am working on Groov EPIC PR2 and want to connect to Azure-IOT-hub because my company uses azure for streaming and visualizing sensor data. When I try to install node-red-contrib-azure-iot-hub 0.5.3 i got the following error. Can someone help here on this. Error log is added here for reference. 024-03-20T08:16:17.120Z Install : @nodecolor/node-red-contrib-azure-iot-hub 0.5.3 2024-03-20T08:16:18.366Z npm install --no-audit --no-update-notifier --no-fund --save --save-prefix=~ --production --...... <less Groovepic not getting connected with Vi network Forum - Published: In India Vi is a renowned mobile service provider. When I am trying to use the hotspot through Vi network then I am unable to access groovepic at my machine. PFB the IP addresses- Hotspot’s IP address...moreIn India Vi is a renowned mobile service provider. When I am trying to use the hotspot through Vi network then I am unable to access groovepic at my machine. PFB the IP addresses- Hotspot’s IP address(at my laptop accessing this IP)-192.168.116.132 IP address to access groovepic at my laptop-192.168.137.68. When I am accessing 192.168.137.68 at chrome then it throws internet timed out error message. Please suggest as to how to access groovepic at laptop through Vi hotspot... <less Can the AS-i network be connected to the R1 controller? Forum - Published: Hello everyone, one of my customers asked me about AS-i. Can his existing AS-i network be connected to the R1 controller? If it is possible, how can I do it? What equipment needs to be added? There is...moreHello everyone, one of my customers asked me about AS-i. Can his existing AS-i network be connected to the R1 controller? If it is possible, how can I do it? What equipment needs to be added? There is an AS-i master station and more than 20 AS-i actuators and sensors. Thanks!... <less Point I/O for EPIC Forum - Published: I would like to know if there is a product that could be used as a Point I/O (like the Allen Bradley Points I/O) I am using this EPIC processor that must activate more than 30 valves that are like 30...moreI would like to know if there is a product that could be used as a Point I/O (like the Allen Bradley Points I/O) I am using this EPIC processor that must activate more than 30 valves that are like 30 feet away from the device. Another EPIC will not be the best solution. I am looking for this Point I/O so I can communicate with them through ethernet IP (or similar).... <less Is There A Limit to Context Data Storage in Node-RED? Forum - Published: I have finally found a method for passing tags from Node-RED to Ignition Edge to use in Ignition Designer, but it requires storing values as Context Data in Node-RED then calling these values in the...moreI have finally found a method for passing tags from Node-RED to Ignition Edge to use in Ignition Designer, but it requires storing values as Context Data in Node-RED then calling these values in the Address Space of an OPC-UA server node (node-red-contrib-opcua-server). However, I will eventually need to pass a much higher volume of data and I’m wondering if using this method will be an issue if there is a limit to how many values I can store as Context Data.... <less Pointer to an Up Timer Forum - Published: I’ve created a pointer table containing pointers to a series of up timers. Here’s an example of how the table values are assigned, see below. SetUpTimerTarget(60, Timer_sec); ptTimerTable[0] = &Timer...moreI’ve created a pointer table containing pointers to a series of up timers. Here’s an example of how the table values are assigned, see below. SetUpTimerTarget(60, Timer_sec); ptTimerTable[0] = &Timer_sec; I then start the time in later code, see below. StartTimer(*ptTimerTable[0]); When Test Compiling I get the following syntax error. Unable to find variable or command “*ptTimerTable[0]” What am I doing wrong here? Thanks in Advance, DKMarion... <less Can I use Ignition Node-RED module with Ignition Edge Free Trial? Forum - Published: I’m attempting to set up an API Key with the Ignition Node-RED module, but am getting an error that the license is invalid. I can’t tell if this is saying that (a) I can’t use this module with Ignition...moreI’m attempting to set up an API Key with the Ignition Node-RED module, but am getting an error that the license is invalid. I can’t tell if this is saying that (a) I can’t use this module with Ignition Edge unless I have an Ignition Edge license (and am not just using the free trial) or (b) I can’t use this module with Ignition Edge because the module license itself is invalid. image1254×213 9.61 KB Has anyone come across this?... <less PAC 10.5 Analog Input - Moving Average Forum - Published: A simple questions that I cannot find documented (or I didn’t look in the right place). The new Moving Average built into the Analog Inputs can be setup to look at X Number of Samples. What determines...moreA simple questions that I cannot find documented (or I didn’t look in the right place). The new Moving Average built into the Analog Inputs can be setup to look at X Number of Samples. What determines the rate of each sample ? A moving average of 10 samples at 1 sec is very different from a moving average of 10 samples at 100msec - both of which I’ve done in the past via logic. Is it based on every time the configuration reads the point (which may or may not be at a set time base) OR is it based...... <less Page 1 of 128Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
MQTT client from Groov EPIC node red keep getting disconnected to azure eventgrid MQTT broker Forum - Published: Hi, I am running MQTT broker in microsoft azure eventgrid and I have generated certificates and keys to connect the Grooc EPIC nodered MQTT out client to eventgrid mqtt broker. When I deploy i could see...moreHi, I am running MQTT broker in microsoft azure eventgrid and I have generated certificates and keys to connect the Grooc EPIC nodered MQTT out client to eventgrid mqtt broker. When I deploy i could see it is connected for 10 seconds. After that it got disconnected and every few seconds it is showing connecting and got disconnected again. I have followed microsoft azure eventgrid tutorials for this and they gave examples for mqttx app for testing purpose. I am not sure what I am missing here and...... <less MQTT Sparkolug B message types with MQTT Sparkplug B out Forum - Published: SparkplugB_04_2024.zip (2.4 KB) Hello. I want to create all message types with “MQTT Sparkplug B out” that would work in Ignition SCADA. NBIRTH and NDATA are working but DBIRTH is rejected and I get back...moreSparkplugB_04_2024.zip (2.4 KB) Hello. I want to create all message types with “MQTT Sparkplug B out” that would work in Ignition SCADA. NBIRTH and NDATA are working but DBIRTH is rejected and I get back Rebirth control. I believe that my DBIRTH message is In accordance with Sparkplug specifications. Does anybody know how to fix the DBIRTH message that would work in Ignition SCADA? Can somebody share the flow in Node-Red where all Sparkplug b message types would work in Ignition SCADA (It can be...... <less Node-Red Sparkplub send JSON datatype Forum - Published: I am trying to set up function to send a JSON Obect to MQTT Broker using sparkplug B. The function is: var jsonObject = msg.payload; // Convert JSON object to string var jsonString = JSON.stringify...moreI am trying to set up function to send a JSON Obect to MQTT Broker using sparkplug B. The function is: var jsonObject = msg.payload; // Convert JSON object to string var jsonString = JSON.stringify(jsonObject); var sparkplugBMessage = { “metrics”: [ { “name”:“RECIPE”, “type”:12, “value”: jsonString } ] }; // Set the stringified JSON as the new payload msg.payload = sparkplugBMessage; //msg.js=jsonObject //msg.jsstring=jsonString // Return the modified message return msg; The debug results are: i...... <less Access Control Systems Forum - Published: Is anyone using any OPTO22 product to operate an Access Control System? We would entertain Wiegland or RFID proximity cards and readers. Our application includes three walk through gates with mag locks...moreIs anyone using any OPTO22 product to operate an Access Control System? We would entertain Wiegland or RFID proximity cards and readers. Our application includes three walk through gates with mag locks and two drive through gates with chain openers. Any advice would be much appreciated. Reay... <less Pac R1 to Automation Direct C More HMI through Modbus Forum - Published: I have a snap-pac-r1w and am trying to connect it to an Automation Direct C-More HMI EA9-T15CL-R Via modbus. The HMI is the master and we have the slave subroutine running in the strategy from the...moreI have a snap-pac-r1w and am trying to connect it to an Automation Direct C-More HMI EA9-T15CL-R Via modbus. The HMI is the master and we have the slave subroutine running in the strategy from the modbus integration kit. For testing purposes we are just using the supplied strategy from the modbus integration kit. Good news: Coils and Ints work fine. Bad news: When entering a float variable on the HMI it goes into the Int holding table over two consecutive values, not to the float holding t...... <less How to start the startegy automatically on power up? Forum - Published: Hello, On a Groov Epic I’d like the strategy runs automatically on power up, with no need to press a button on HMI or with PAC control. I checked the documentation, tried to find something on the forum...moreHello, On a Groov Epic I’d like the strategy runs automatically on power up, with no need to press a button on HMI or with PAC control. I checked the documentation, tried to find something on the forum but can’t get a clear answer. Thanks for your help.... <less Having a hard time with installing Tailscale on EPIC Forum - Published: Hello, I am trying to follow this guide from Corso Systems Corso Systems Tailscale on Opto22 groov Hardware | Corso Systems Corso Systems walks through setting up...moreHello, I am trying to follow this guide from Corso Systems Corso Systems Tailscale on Opto22 groov Hardware | Corso Systems Corso Systems walks through setting up Tailscale on an Opto22 groov RIO. Tailscale is built on the Wireguard framework, but can be easier to configure depending on your IT skillset. And I keep getting this error after I do the wget https://pkgs.tailscale.com/stable/tailscale_1.62.0_arm.tgz Connecting to pkgs.tails...... <less Fail to connect node-red to websocket (postman) Forum - Published: Fail to connect node-red to websocket (postman) because of Error on self signed certificate… Groove Rio, How listen to groove value to websocket… ...Fail to connect node-red to websocket (postman) because of Error on self signed certificate… Groove Rio, How listen to groove value to websocket… ... <less PAC Controller blocking port 22001? Forum - Published: I have a system using a SNAP-PAC-R1 for I/O, using an old program (Lookout by National Instruments) and we want to start using PAC Control instead. So I made a strategy and tried to download it to the...moreI have a system using a SNAP-PAC-R1 for I/O, using an old program (Lookout by National Instruments) and we want to start using PAC Control instead. So I made a strategy and tried to download it to the controller and got an error code -10057. The Ethernet connection is definitely there; I can ping the controller (10.90.150.56) from the PC with PAC Control (10.90.150.2). Both are on the same subnet. I asked my network admin if the switches might be blocking communication through port 22001, and he...... <less Groov View plug in display refresh rate Forum - Published: I have displayed the groov View interface using the local browser on a groov EPIC controller across a company network, and used a Dell touch screen monitor plugged directly into the HDMI port and USB...moreI have displayed the groov View interface using the local browser on a groov EPIC controller across a company network, and used a Dell touch screen monitor plugged directly into the HDMI port and USB port of the groov EPIC. The HDMI connection has a refresh time from 1 to 4 seconds, and the remote browsers refresh is 1 second or less. On another tech support issue, I was told that the local browser that is used for the HDMI connection has a bug and will be updated in the next firmware release of...... <less Unable to install node-red-contrib-azure-iot-hub 0.5.3 in Groov EPIC Forum - Published: Hi, I am working on Groov EPIC PR2 and want to connect to Azure-IOT-hub because my company uses azure for streaming and visualizing sensor data. When I try to install node-red-contrib-azure-iot-hub 0.5...moreHi, I am working on Groov EPIC PR2 and want to connect to Azure-IOT-hub because my company uses azure for streaming and visualizing sensor data. When I try to install node-red-contrib-azure-iot-hub 0.5.3 i got the following error. Can someone help here on this. Error log is added here for reference. 024-03-20T08:16:17.120Z Install : @nodecolor/node-red-contrib-azure-iot-hub 0.5.3 2024-03-20T08:16:18.366Z npm install --no-audit --no-update-notifier --no-fund --save --save-prefix=~ --production --...... <less Groovepic not getting connected with Vi network Forum - Published: In India Vi is a renowned mobile service provider. When I am trying to use the hotspot through Vi network then I am unable to access groovepic at my machine. PFB the IP addresses- Hotspot’s IP address...moreIn India Vi is a renowned mobile service provider. When I am trying to use the hotspot through Vi network then I am unable to access groovepic at my machine. PFB the IP addresses- Hotspot’s IP address(at my laptop accessing this IP)-192.168.116.132 IP address to access groovepic at my laptop-192.168.137.68. When I am accessing 192.168.137.68 at chrome then it throws internet timed out error message. Please suggest as to how to access groovepic at laptop through Vi hotspot... <less Can the AS-i network be connected to the R1 controller? Forum - Published: Hello everyone, one of my customers asked me about AS-i. Can his existing AS-i network be connected to the R1 controller? If it is possible, how can I do it? What equipment needs to be added? There is...moreHello everyone, one of my customers asked me about AS-i. Can his existing AS-i network be connected to the R1 controller? If it is possible, how can I do it? What equipment needs to be added? There is an AS-i master station and more than 20 AS-i actuators and sensors. Thanks!... <less Point I/O for EPIC Forum - Published: I would like to know if there is a product that could be used as a Point I/O (like the Allen Bradley Points I/O) I am using this EPIC processor that must activate more than 30 valves that are like 30...moreI would like to know if there is a product that could be used as a Point I/O (like the Allen Bradley Points I/O) I am using this EPIC processor that must activate more than 30 valves that are like 30 feet away from the device. Another EPIC will not be the best solution. I am looking for this Point I/O so I can communicate with them through ethernet IP (or similar).... <less Is There A Limit to Context Data Storage in Node-RED? Forum - Published: I have finally found a method for passing tags from Node-RED to Ignition Edge to use in Ignition Designer, but it requires storing values as Context Data in Node-RED then calling these values in the...moreI have finally found a method for passing tags from Node-RED to Ignition Edge to use in Ignition Designer, but it requires storing values as Context Data in Node-RED then calling these values in the Address Space of an OPC-UA server node (node-red-contrib-opcua-server). However, I will eventually need to pass a much higher volume of data and I’m wondering if using this method will be an issue if there is a limit to how many values I can store as Context Data.... <less Pointer to an Up Timer Forum - Published: I’ve created a pointer table containing pointers to a series of up timers. Here’s an example of how the table values are assigned, see below. SetUpTimerTarget(60, Timer_sec); ptTimerTable[0] = &Timer...moreI’ve created a pointer table containing pointers to a series of up timers. Here’s an example of how the table values are assigned, see below. SetUpTimerTarget(60, Timer_sec); ptTimerTable[0] = &Timer_sec; I then start the time in later code, see below. StartTimer(*ptTimerTable[0]); When Test Compiling I get the following syntax error. Unable to find variable or command “*ptTimerTable[0]” What am I doing wrong here? Thanks in Advance, DKMarion... <less Can I use Ignition Node-RED module with Ignition Edge Free Trial? Forum - Published: I’m attempting to set up an API Key with the Ignition Node-RED module, but am getting an error that the license is invalid. I can’t tell if this is saying that (a) I can’t use this module with Ignition...moreI’m attempting to set up an API Key with the Ignition Node-RED module, but am getting an error that the license is invalid. I can’t tell if this is saying that (a) I can’t use this module with Ignition Edge unless I have an Ignition Edge license (and am not just using the free trial) or (b) I can’t use this module with Ignition Edge because the module license itself is invalid. image1254×213 9.61 KB Has anyone come across this?... <less PAC 10.5 Analog Input - Moving Average Forum - Published: A simple questions that I cannot find documented (or I didn’t look in the right place). The new Moving Average built into the Analog Inputs can be setup to look at X Number of Samples. What determines...moreA simple questions that I cannot find documented (or I didn’t look in the right place). The new Moving Average built into the Analog Inputs can be setup to look at X Number of Samples. What determines the rate of each sample ? A moving average of 10 samples at 1 sec is very different from a moving average of 10 samples at 100msec - both of which I’ve done in the past via logic. Is it based on every time the configuration reads the point (which may or may not be at a set time base) OR is it based...... <less Page 1 of 128Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
MQTT Sparkolug B message types with MQTT Sparkplug B out Forum - Published: SparkplugB_04_2024.zip (2.4 KB) Hello. I want to create all message types with “MQTT Sparkplug B out” that would work in Ignition SCADA. NBIRTH and NDATA are working but DBIRTH is rejected and I get back...moreSparkplugB_04_2024.zip (2.4 KB) Hello. I want to create all message types with “MQTT Sparkplug B out” that would work in Ignition SCADA. NBIRTH and NDATA are working but DBIRTH is rejected and I get back Rebirth control. I believe that my DBIRTH message is In accordance with Sparkplug specifications. Does anybody know how to fix the DBIRTH message that would work in Ignition SCADA? Can somebody share the flow in Node-Red where all Sparkplug b message types would work in Ignition SCADA (It can be...... <less Node-Red Sparkplub send JSON datatype Forum - Published: I am trying to set up function to send a JSON Obect to MQTT Broker using sparkplug B. The function is: var jsonObject = msg.payload; // Convert JSON object to string var jsonString = JSON.stringify...moreI am trying to set up function to send a JSON Obect to MQTT Broker using sparkplug B. The function is: var jsonObject = msg.payload; // Convert JSON object to string var jsonString = JSON.stringify(jsonObject); var sparkplugBMessage = { “metrics”: [ { “name”:“RECIPE”, “type”:12, “value”: jsonString } ] }; // Set the stringified JSON as the new payload msg.payload = sparkplugBMessage; //msg.js=jsonObject //msg.jsstring=jsonString // Return the modified message return msg; The debug results are: i...... <less Access Control Systems Forum - Published: Is anyone using any OPTO22 product to operate an Access Control System? We would entertain Wiegland or RFID proximity cards and readers. Our application includes three walk through gates with mag locks...moreIs anyone using any OPTO22 product to operate an Access Control System? We would entertain Wiegland or RFID proximity cards and readers. Our application includes three walk through gates with mag locks and two drive through gates with chain openers. Any advice would be much appreciated. Reay... <less Pac R1 to Automation Direct C More HMI through Modbus Forum - Published: I have a snap-pac-r1w and am trying to connect it to an Automation Direct C-More HMI EA9-T15CL-R Via modbus. The HMI is the master and we have the slave subroutine running in the strategy from the...moreI have a snap-pac-r1w and am trying to connect it to an Automation Direct C-More HMI EA9-T15CL-R Via modbus. The HMI is the master and we have the slave subroutine running in the strategy from the modbus integration kit. For testing purposes we are just using the supplied strategy from the modbus integration kit. Good news: Coils and Ints work fine. Bad news: When entering a float variable on the HMI it goes into the Int holding table over two consecutive values, not to the float holding t...... <less How to start the startegy automatically on power up? Forum - Published: Hello, On a Groov Epic I’d like the strategy runs automatically on power up, with no need to press a button on HMI or with PAC control. I checked the documentation, tried to find something on the forum...moreHello, On a Groov Epic I’d like the strategy runs automatically on power up, with no need to press a button on HMI or with PAC control. I checked the documentation, tried to find something on the forum but can’t get a clear answer. Thanks for your help.... <less Having a hard time with installing Tailscale on EPIC Forum - Published: Hello, I am trying to follow this guide from Corso Systems Corso Systems Tailscale on Opto22 groov Hardware | Corso Systems Corso Systems walks through setting up...moreHello, I am trying to follow this guide from Corso Systems Corso Systems Tailscale on Opto22 groov Hardware | Corso Systems Corso Systems walks through setting up Tailscale on an Opto22 groov RIO. Tailscale is built on the Wireguard framework, but can be easier to configure depending on your IT skillset. And I keep getting this error after I do the wget https://pkgs.tailscale.com/stable/tailscale_1.62.0_arm.tgz Connecting to pkgs.tails...... <less Fail to connect node-red to websocket (postman) Forum - Published: Fail to connect node-red to websocket (postman) because of Error on self signed certificate… Groove Rio, How listen to groove value to websocket… ...Fail to connect node-red to websocket (postman) because of Error on self signed certificate… Groove Rio, How listen to groove value to websocket… ... <less PAC Controller blocking port 22001? Forum - Published: I have a system using a SNAP-PAC-R1 for I/O, using an old program (Lookout by National Instruments) and we want to start using PAC Control instead. So I made a strategy and tried to download it to the...moreI have a system using a SNAP-PAC-R1 for I/O, using an old program (Lookout by National Instruments) and we want to start using PAC Control instead. So I made a strategy and tried to download it to the controller and got an error code -10057. The Ethernet connection is definitely there; I can ping the controller (10.90.150.56) from the PC with PAC Control (10.90.150.2). Both are on the same subnet. I asked my network admin if the switches might be blocking communication through port 22001, and he...... <less Groov View plug in display refresh rate Forum - Published: I have displayed the groov View interface using the local browser on a groov EPIC controller across a company network, and used a Dell touch screen monitor plugged directly into the HDMI port and USB...moreI have displayed the groov View interface using the local browser on a groov EPIC controller across a company network, and used a Dell touch screen monitor plugged directly into the HDMI port and USB port of the groov EPIC. The HDMI connection has a refresh time from 1 to 4 seconds, and the remote browsers refresh is 1 second or less. On another tech support issue, I was told that the local browser that is used for the HDMI connection has a bug and will be updated in the next firmware release of...... <less Unable to install node-red-contrib-azure-iot-hub 0.5.3 in Groov EPIC Forum - Published: Hi, I am working on Groov EPIC PR2 and want to connect to Azure-IOT-hub because my company uses azure for streaming and visualizing sensor data. When I try to install node-red-contrib-azure-iot-hub 0.5...moreHi, I am working on Groov EPIC PR2 and want to connect to Azure-IOT-hub because my company uses azure for streaming and visualizing sensor data. When I try to install node-red-contrib-azure-iot-hub 0.5.3 i got the following error. Can someone help here on this. Error log is added here for reference. 024-03-20T08:16:17.120Z Install : @nodecolor/node-red-contrib-azure-iot-hub 0.5.3 2024-03-20T08:16:18.366Z npm install --no-audit --no-update-notifier --no-fund --save --save-prefix=~ --production --...... <less Groovepic not getting connected with Vi network Forum - Published: In India Vi is a renowned mobile service provider. When I am trying to use the hotspot through Vi network then I am unable to access groovepic at my machine. PFB the IP addresses- Hotspot’s IP address...moreIn India Vi is a renowned mobile service provider. When I am trying to use the hotspot through Vi network then I am unable to access groovepic at my machine. PFB the IP addresses- Hotspot’s IP address(at my laptop accessing this IP)-192.168.116.132 IP address to access groovepic at my laptop-192.168.137.68. When I am accessing 192.168.137.68 at chrome then it throws internet timed out error message. Please suggest as to how to access groovepic at laptop through Vi hotspot... <less Can the AS-i network be connected to the R1 controller? Forum - Published: Hello everyone, one of my customers asked me about AS-i. Can his existing AS-i network be connected to the R1 controller? If it is possible, how can I do it? What equipment needs to be added? There is...moreHello everyone, one of my customers asked me about AS-i. Can his existing AS-i network be connected to the R1 controller? If it is possible, how can I do it? What equipment needs to be added? There is an AS-i master station and more than 20 AS-i actuators and sensors. Thanks!... <less Point I/O for EPIC Forum - Published: I would like to know if there is a product that could be used as a Point I/O (like the Allen Bradley Points I/O) I am using this EPIC processor that must activate more than 30 valves that are like 30...moreI would like to know if there is a product that could be used as a Point I/O (like the Allen Bradley Points I/O) I am using this EPIC processor that must activate more than 30 valves that are like 30 feet away from the device. Another EPIC will not be the best solution. I am looking for this Point I/O so I can communicate with them through ethernet IP (or similar).... <less Is There A Limit to Context Data Storage in Node-RED? Forum - Published: I have finally found a method for passing tags from Node-RED to Ignition Edge to use in Ignition Designer, but it requires storing values as Context Data in Node-RED then calling these values in the...moreI have finally found a method for passing tags from Node-RED to Ignition Edge to use in Ignition Designer, but it requires storing values as Context Data in Node-RED then calling these values in the Address Space of an OPC-UA server node (node-red-contrib-opcua-server). However, I will eventually need to pass a much higher volume of data and I’m wondering if using this method will be an issue if there is a limit to how many values I can store as Context Data.... <less Pointer to an Up Timer Forum - Published: I’ve created a pointer table containing pointers to a series of up timers. Here’s an example of how the table values are assigned, see below. SetUpTimerTarget(60, Timer_sec); ptTimerTable[0] = &Timer...moreI’ve created a pointer table containing pointers to a series of up timers. Here’s an example of how the table values are assigned, see below. SetUpTimerTarget(60, Timer_sec); ptTimerTable[0] = &Timer_sec; I then start the time in later code, see below. StartTimer(*ptTimerTable[0]); When Test Compiling I get the following syntax error. Unable to find variable or command “*ptTimerTable[0]” What am I doing wrong here? Thanks in Advance, DKMarion... <less Can I use Ignition Node-RED module with Ignition Edge Free Trial? Forum - Published: I’m attempting to set up an API Key with the Ignition Node-RED module, but am getting an error that the license is invalid. I can’t tell if this is saying that (a) I can’t use this module with Ignition...moreI’m attempting to set up an API Key with the Ignition Node-RED module, but am getting an error that the license is invalid. I can’t tell if this is saying that (a) I can’t use this module with Ignition Edge unless I have an Ignition Edge license (and am not just using the free trial) or (b) I can’t use this module with Ignition Edge because the module license itself is invalid. image1254×213 9.61 KB Has anyone come across this?... <less PAC 10.5 Analog Input - Moving Average Forum - Published: A simple questions that I cannot find documented (or I didn’t look in the right place). The new Moving Average built into the Analog Inputs can be setup to look at X Number of Samples. What determines...moreA simple questions that I cannot find documented (or I didn’t look in the right place). The new Moving Average built into the Analog Inputs can be setup to look at X Number of Samples. What determines the rate of each sample ? A moving average of 10 samples at 1 sec is very different from a moving average of 10 samples at 100msec - both of which I’ve done in the past via logic. Is it based on every time the configuration reads the point (which may or may not be at a set time base) OR is it based...... <less Page 1 of 128Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Node-Red Sparkplub send JSON datatype Forum - Published: I am trying to set up function to send a JSON Obect to MQTT Broker using sparkplug B. The function is: var jsonObject = msg.payload; // Convert JSON object to string var jsonString = JSON.stringify...moreI am trying to set up function to send a JSON Obect to MQTT Broker using sparkplug B. The function is: var jsonObject = msg.payload; // Convert JSON object to string var jsonString = JSON.stringify(jsonObject); var sparkplugBMessage = { “metrics”: [ { “name”:“RECIPE”, “type”:12, “value”: jsonString } ] }; // Set the stringified JSON as the new payload msg.payload = sparkplugBMessage; //msg.js=jsonObject //msg.jsstring=jsonString // Return the modified message return msg; The debug results are: i...... <less Access Control Systems Forum - Published: Is anyone using any OPTO22 product to operate an Access Control System? We would entertain Wiegland or RFID proximity cards and readers. Our application includes three walk through gates with mag locks...moreIs anyone using any OPTO22 product to operate an Access Control System? We would entertain Wiegland or RFID proximity cards and readers. Our application includes three walk through gates with mag locks and two drive through gates with chain openers. Any advice would be much appreciated. Reay... <less Pac R1 to Automation Direct C More HMI through Modbus Forum - Published: I have a snap-pac-r1w and am trying to connect it to an Automation Direct C-More HMI EA9-T15CL-R Via modbus. The HMI is the master and we have the slave subroutine running in the strategy from the...moreI have a snap-pac-r1w and am trying to connect it to an Automation Direct C-More HMI EA9-T15CL-R Via modbus. The HMI is the master and we have the slave subroutine running in the strategy from the modbus integration kit. For testing purposes we are just using the supplied strategy from the modbus integration kit. Good news: Coils and Ints work fine. Bad news: When entering a float variable on the HMI it goes into the Int holding table over two consecutive values, not to the float holding t...... <less How to start the startegy automatically on power up? Forum - Published: Hello, On a Groov Epic I’d like the strategy runs automatically on power up, with no need to press a button on HMI or with PAC control. I checked the documentation, tried to find something on the forum...moreHello, On a Groov Epic I’d like the strategy runs automatically on power up, with no need to press a button on HMI or with PAC control. I checked the documentation, tried to find something on the forum but can’t get a clear answer. Thanks for your help.... <less Having a hard time with installing Tailscale on EPIC Forum - Published: Hello, I am trying to follow this guide from Corso Systems Corso Systems Tailscale on Opto22 groov Hardware | Corso Systems Corso Systems walks through setting up...moreHello, I am trying to follow this guide from Corso Systems Corso Systems Tailscale on Opto22 groov Hardware | Corso Systems Corso Systems walks through setting up Tailscale on an Opto22 groov RIO. Tailscale is built on the Wireguard framework, but can be easier to configure depending on your IT skillset. And I keep getting this error after I do the wget https://pkgs.tailscale.com/stable/tailscale_1.62.0_arm.tgz Connecting to pkgs.tails...... <less Fail to connect node-red to websocket (postman) Forum - Published: Fail to connect node-red to websocket (postman) because of Error on self signed certificate… Groove Rio, How listen to groove value to websocket… ...Fail to connect node-red to websocket (postman) because of Error on self signed certificate… Groove Rio, How listen to groove value to websocket… ... <less PAC Controller blocking port 22001? Forum - Published: I have a system using a SNAP-PAC-R1 for I/O, using an old program (Lookout by National Instruments) and we want to start using PAC Control instead. So I made a strategy and tried to download it to the...moreI have a system using a SNAP-PAC-R1 for I/O, using an old program (Lookout by National Instruments) and we want to start using PAC Control instead. So I made a strategy and tried to download it to the controller and got an error code -10057. The Ethernet connection is definitely there; I can ping the controller (10.90.150.56) from the PC with PAC Control (10.90.150.2). Both are on the same subnet. I asked my network admin if the switches might be blocking communication through port 22001, and he...... <less Groov View plug in display refresh rate Forum - Published: I have displayed the groov View interface using the local browser on a groov EPIC controller across a company network, and used a Dell touch screen monitor plugged directly into the HDMI port and USB...moreI have displayed the groov View interface using the local browser on a groov EPIC controller across a company network, and used a Dell touch screen monitor plugged directly into the HDMI port and USB port of the groov EPIC. The HDMI connection has a refresh time from 1 to 4 seconds, and the remote browsers refresh is 1 second or less. On another tech support issue, I was told that the local browser that is used for the HDMI connection has a bug and will be updated in the next firmware release of...... <less Unable to install node-red-contrib-azure-iot-hub 0.5.3 in Groov EPIC Forum - Published: Hi, I am working on Groov EPIC PR2 and want to connect to Azure-IOT-hub because my company uses azure for streaming and visualizing sensor data. When I try to install node-red-contrib-azure-iot-hub 0.5...moreHi, I am working on Groov EPIC PR2 and want to connect to Azure-IOT-hub because my company uses azure for streaming and visualizing sensor data. When I try to install node-red-contrib-azure-iot-hub 0.5.3 i got the following error. Can someone help here on this. Error log is added here for reference. 024-03-20T08:16:17.120Z Install : @nodecolor/node-red-contrib-azure-iot-hub 0.5.3 2024-03-20T08:16:18.366Z npm install --no-audit --no-update-notifier --no-fund --save --save-prefix=~ --production --...... <less Groovepic not getting connected with Vi network Forum - Published: In India Vi is a renowned mobile service provider. When I am trying to use the hotspot through Vi network then I am unable to access groovepic at my machine. PFB the IP addresses- Hotspot’s IP address...moreIn India Vi is a renowned mobile service provider. When I am trying to use the hotspot through Vi network then I am unable to access groovepic at my machine. PFB the IP addresses- Hotspot’s IP address(at my laptop accessing this IP)-192.168.116.132 IP address to access groovepic at my laptop-192.168.137.68. When I am accessing 192.168.137.68 at chrome then it throws internet timed out error message. Please suggest as to how to access groovepic at laptop through Vi hotspot... <less Can the AS-i network be connected to the R1 controller? Forum - Published: Hello everyone, one of my customers asked me about AS-i. Can his existing AS-i network be connected to the R1 controller? If it is possible, how can I do it? What equipment needs to be added? There is...moreHello everyone, one of my customers asked me about AS-i. Can his existing AS-i network be connected to the R1 controller? If it is possible, how can I do it? What equipment needs to be added? There is an AS-i master station and more than 20 AS-i actuators and sensors. Thanks!... <less Point I/O for EPIC Forum - Published: I would like to know if there is a product that could be used as a Point I/O (like the Allen Bradley Points I/O) I am using this EPIC processor that must activate more than 30 valves that are like 30...moreI would like to know if there is a product that could be used as a Point I/O (like the Allen Bradley Points I/O) I am using this EPIC processor that must activate more than 30 valves that are like 30 feet away from the device. Another EPIC will not be the best solution. I am looking for this Point I/O so I can communicate with them through ethernet IP (or similar).... <less Is There A Limit to Context Data Storage in Node-RED? Forum - Published: I have finally found a method for passing tags from Node-RED to Ignition Edge to use in Ignition Designer, but it requires storing values as Context Data in Node-RED then calling these values in the...moreI have finally found a method for passing tags from Node-RED to Ignition Edge to use in Ignition Designer, but it requires storing values as Context Data in Node-RED then calling these values in the Address Space of an OPC-UA server node (node-red-contrib-opcua-server). However, I will eventually need to pass a much higher volume of data and I’m wondering if using this method will be an issue if there is a limit to how many values I can store as Context Data.... <less Pointer to an Up Timer Forum - Published: I’ve created a pointer table containing pointers to a series of up timers. Here’s an example of how the table values are assigned, see below. SetUpTimerTarget(60, Timer_sec); ptTimerTable[0] = &Timer...moreI’ve created a pointer table containing pointers to a series of up timers. Here’s an example of how the table values are assigned, see below. SetUpTimerTarget(60, Timer_sec); ptTimerTable[0] = &Timer_sec; I then start the time in later code, see below. StartTimer(*ptTimerTable[0]); When Test Compiling I get the following syntax error. Unable to find variable or command “*ptTimerTable[0]” What am I doing wrong here? Thanks in Advance, DKMarion... <less Can I use Ignition Node-RED module with Ignition Edge Free Trial? Forum - Published: I’m attempting to set up an API Key with the Ignition Node-RED module, but am getting an error that the license is invalid. I can’t tell if this is saying that (a) I can’t use this module with Ignition...moreI’m attempting to set up an API Key with the Ignition Node-RED module, but am getting an error that the license is invalid. I can’t tell if this is saying that (a) I can’t use this module with Ignition Edge unless I have an Ignition Edge license (and am not just using the free trial) or (b) I can’t use this module with Ignition Edge because the module license itself is invalid. image1254×213 9.61 KB Has anyone come across this?... <less PAC 10.5 Analog Input - Moving Average Forum - Published: A simple questions that I cannot find documented (or I didn’t look in the right place). The new Moving Average built into the Analog Inputs can be setup to look at X Number of Samples. What determines...moreA simple questions that I cannot find documented (or I didn’t look in the right place). The new Moving Average built into the Analog Inputs can be setup to look at X Number of Samples. What determines the rate of each sample ? A moving average of 10 samples at 1 sec is very different from a moving average of 10 samples at 100msec - both of which I’ve done in the past via logic. Is it based on every time the configuration reads the point (which may or may not be at a set time base) OR is it based...... <less Page 1 of 128Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Access Control Systems Forum - Published: Is anyone using any OPTO22 product to operate an Access Control System? We would entertain Wiegland or RFID proximity cards and readers. Our application includes three walk through gates with mag locks...moreIs anyone using any OPTO22 product to operate an Access Control System? We would entertain Wiegland or RFID proximity cards and readers. Our application includes three walk through gates with mag locks and two drive through gates with chain openers. Any advice would be much appreciated. Reay... <less Pac R1 to Automation Direct C More HMI through Modbus Forum - Published: I have a snap-pac-r1w and am trying to connect it to an Automation Direct C-More HMI EA9-T15CL-R Via modbus. The HMI is the master and we have the slave subroutine running in the strategy from the...moreI have a snap-pac-r1w and am trying to connect it to an Automation Direct C-More HMI EA9-T15CL-R Via modbus. The HMI is the master and we have the slave subroutine running in the strategy from the modbus integration kit. For testing purposes we are just using the supplied strategy from the modbus integration kit. Good news: Coils and Ints work fine. Bad news: When entering a float variable on the HMI it goes into the Int holding table over two consecutive values, not to the float holding t...... <less How to start the startegy automatically on power up? Forum - Published: Hello, On a Groov Epic I’d like the strategy runs automatically on power up, with no need to press a button on HMI or with PAC control. I checked the documentation, tried to find something on the forum...moreHello, On a Groov Epic I’d like the strategy runs automatically on power up, with no need to press a button on HMI or with PAC control. I checked the documentation, tried to find something on the forum but can’t get a clear answer. Thanks for your help.... <less Having a hard time with installing Tailscale on EPIC Forum - Published: Hello, I am trying to follow this guide from Corso Systems Corso Systems Tailscale on Opto22 groov Hardware | Corso Systems Corso Systems walks through setting up...moreHello, I am trying to follow this guide from Corso Systems Corso Systems Tailscale on Opto22 groov Hardware | Corso Systems Corso Systems walks through setting up Tailscale on an Opto22 groov RIO. Tailscale is built on the Wireguard framework, but can be easier to configure depending on your IT skillset. And I keep getting this error after I do the wget https://pkgs.tailscale.com/stable/tailscale_1.62.0_arm.tgz Connecting to pkgs.tails...... <less Fail to connect node-red to websocket (postman) Forum - Published: Fail to connect node-red to websocket (postman) because of Error on self signed certificate… Groove Rio, How listen to groove value to websocket… ...Fail to connect node-red to websocket (postman) because of Error on self signed certificate… Groove Rio, How listen to groove value to websocket… ... <less PAC Controller blocking port 22001? Forum - Published: I have a system using a SNAP-PAC-R1 for I/O, using an old program (Lookout by National Instruments) and we want to start using PAC Control instead. So I made a strategy and tried to download it to the...moreI have a system using a SNAP-PAC-R1 for I/O, using an old program (Lookout by National Instruments) and we want to start using PAC Control instead. So I made a strategy and tried to download it to the controller and got an error code -10057. The Ethernet connection is definitely there; I can ping the controller (10.90.150.56) from the PC with PAC Control (10.90.150.2). Both are on the same subnet. I asked my network admin if the switches might be blocking communication through port 22001, and he...... <less Groov View plug in display refresh rate Forum - Published: I have displayed the groov View interface using the local browser on a groov EPIC controller across a company network, and used a Dell touch screen monitor plugged directly into the HDMI port and USB...moreI have displayed the groov View interface using the local browser on a groov EPIC controller across a company network, and used a Dell touch screen monitor plugged directly into the HDMI port and USB port of the groov EPIC. The HDMI connection has a refresh time from 1 to 4 seconds, and the remote browsers refresh is 1 second or less. On another tech support issue, I was told that the local browser that is used for the HDMI connection has a bug and will be updated in the next firmware release of...... <less Unable to install node-red-contrib-azure-iot-hub 0.5.3 in Groov EPIC Forum - Published: Hi, I am working on Groov EPIC PR2 and want to connect to Azure-IOT-hub because my company uses azure for streaming and visualizing sensor data. When I try to install node-red-contrib-azure-iot-hub 0.5...moreHi, I am working on Groov EPIC PR2 and want to connect to Azure-IOT-hub because my company uses azure for streaming and visualizing sensor data. When I try to install node-red-contrib-azure-iot-hub 0.5.3 i got the following error. Can someone help here on this. Error log is added here for reference. 024-03-20T08:16:17.120Z Install : @nodecolor/node-red-contrib-azure-iot-hub 0.5.3 2024-03-20T08:16:18.366Z npm install --no-audit --no-update-notifier --no-fund --save --save-prefix=~ --production --...... <less Groovepic not getting connected with Vi network Forum - Published: In India Vi is a renowned mobile service provider. When I am trying to use the hotspot through Vi network then I am unable to access groovepic at my machine. PFB the IP addresses- Hotspot’s IP address...moreIn India Vi is a renowned mobile service provider. When I am trying to use the hotspot through Vi network then I am unable to access groovepic at my machine. PFB the IP addresses- Hotspot’s IP address(at my laptop accessing this IP)-192.168.116.132 IP address to access groovepic at my laptop-192.168.137.68. When I am accessing 192.168.137.68 at chrome then it throws internet timed out error message. Please suggest as to how to access groovepic at laptop through Vi hotspot... <less Can the AS-i network be connected to the R1 controller? Forum - Published: Hello everyone, one of my customers asked me about AS-i. Can his existing AS-i network be connected to the R1 controller? If it is possible, how can I do it? What equipment needs to be added? There is...moreHello everyone, one of my customers asked me about AS-i. Can his existing AS-i network be connected to the R1 controller? If it is possible, how can I do it? What equipment needs to be added? There is an AS-i master station and more than 20 AS-i actuators and sensors. Thanks!... <less Point I/O for EPIC Forum - Published: I would like to know if there is a product that could be used as a Point I/O (like the Allen Bradley Points I/O) I am using this EPIC processor that must activate more than 30 valves that are like 30...moreI would like to know if there is a product that could be used as a Point I/O (like the Allen Bradley Points I/O) I am using this EPIC processor that must activate more than 30 valves that are like 30 feet away from the device. Another EPIC will not be the best solution. I am looking for this Point I/O so I can communicate with them through ethernet IP (or similar).... <less Is There A Limit to Context Data Storage in Node-RED? Forum - Published: I have finally found a method for passing tags from Node-RED to Ignition Edge to use in Ignition Designer, but it requires storing values as Context Data in Node-RED then calling these values in the...moreI have finally found a method for passing tags from Node-RED to Ignition Edge to use in Ignition Designer, but it requires storing values as Context Data in Node-RED then calling these values in the Address Space of an OPC-UA server node (node-red-contrib-opcua-server). However, I will eventually need to pass a much higher volume of data and I’m wondering if using this method will be an issue if there is a limit to how many values I can store as Context Data.... <less Pointer to an Up Timer Forum - Published: I’ve created a pointer table containing pointers to a series of up timers. Here’s an example of how the table values are assigned, see below. SetUpTimerTarget(60, Timer_sec); ptTimerTable[0] = &Timer...moreI’ve created a pointer table containing pointers to a series of up timers. Here’s an example of how the table values are assigned, see below. SetUpTimerTarget(60, Timer_sec); ptTimerTable[0] = &Timer_sec; I then start the time in later code, see below. StartTimer(*ptTimerTable[0]); When Test Compiling I get the following syntax error. Unable to find variable or command “*ptTimerTable[0]” What am I doing wrong here? Thanks in Advance, DKMarion... <less Can I use Ignition Node-RED module with Ignition Edge Free Trial? Forum - Published: I’m attempting to set up an API Key with the Ignition Node-RED module, but am getting an error that the license is invalid. I can’t tell if this is saying that (a) I can’t use this module with Ignition...moreI’m attempting to set up an API Key with the Ignition Node-RED module, but am getting an error that the license is invalid. I can’t tell if this is saying that (a) I can’t use this module with Ignition Edge unless I have an Ignition Edge license (and am not just using the free trial) or (b) I can’t use this module with Ignition Edge because the module license itself is invalid. image1254×213 9.61 KB Has anyone come across this?... <less PAC 10.5 Analog Input - Moving Average Forum - Published: A simple questions that I cannot find documented (or I didn’t look in the right place). The new Moving Average built into the Analog Inputs can be setup to look at X Number of Samples. What determines...moreA simple questions that I cannot find documented (or I didn’t look in the right place). The new Moving Average built into the Analog Inputs can be setup to look at X Number of Samples. What determines the rate of each sample ? A moving average of 10 samples at 1 sec is very different from a moving average of 10 samples at 100msec - both of which I’ve done in the past via logic. Is it based on every time the configuration reads the point (which may or may not be at a set time base) OR is it based...... <less Page 1 of 128Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Pac R1 to Automation Direct C More HMI through Modbus Forum - Published: I have a snap-pac-r1w and am trying to connect it to an Automation Direct C-More HMI EA9-T15CL-R Via modbus. The HMI is the master and we have the slave subroutine running in the strategy from the...moreI have a snap-pac-r1w and am trying to connect it to an Automation Direct C-More HMI EA9-T15CL-R Via modbus. The HMI is the master and we have the slave subroutine running in the strategy from the modbus integration kit. For testing purposes we are just using the supplied strategy from the modbus integration kit. Good news: Coils and Ints work fine. Bad news: When entering a float variable on the HMI it goes into the Int holding table over two consecutive values, not to the float holding t...... <less How to start the startegy automatically on power up? Forum - Published: Hello, On a Groov Epic I’d like the strategy runs automatically on power up, with no need to press a button on HMI or with PAC control. I checked the documentation, tried to find something on the forum...moreHello, On a Groov Epic I’d like the strategy runs automatically on power up, with no need to press a button on HMI or with PAC control. I checked the documentation, tried to find something on the forum but can’t get a clear answer. Thanks for your help.... <less Having a hard time with installing Tailscale on EPIC Forum - Published: Hello, I am trying to follow this guide from Corso Systems Corso Systems Tailscale on Opto22 groov Hardware | Corso Systems Corso Systems walks through setting up...moreHello, I am trying to follow this guide from Corso Systems Corso Systems Tailscale on Opto22 groov Hardware | Corso Systems Corso Systems walks through setting up Tailscale on an Opto22 groov RIO. Tailscale is built on the Wireguard framework, but can be easier to configure depending on your IT skillset. And I keep getting this error after I do the wget https://pkgs.tailscale.com/stable/tailscale_1.62.0_arm.tgz Connecting to pkgs.tails...... <less Fail to connect node-red to websocket (postman) Forum - Published: Fail to connect node-red to websocket (postman) because of Error on self signed certificate… Groove Rio, How listen to groove value to websocket… ...Fail to connect node-red to websocket (postman) because of Error on self signed certificate… Groove Rio, How listen to groove value to websocket… ... <less PAC Controller blocking port 22001? Forum - Published: I have a system using a SNAP-PAC-R1 for I/O, using an old program (Lookout by National Instruments) and we want to start using PAC Control instead. So I made a strategy and tried to download it to the...moreI have a system using a SNAP-PAC-R1 for I/O, using an old program (Lookout by National Instruments) and we want to start using PAC Control instead. So I made a strategy and tried to download it to the controller and got an error code -10057. The Ethernet connection is definitely there; I can ping the controller (10.90.150.56) from the PC with PAC Control (10.90.150.2). Both are on the same subnet. I asked my network admin if the switches might be blocking communication through port 22001, and he...... <less Groov View plug in display refresh rate Forum - Published: I have displayed the groov View interface using the local browser on a groov EPIC controller across a company network, and used a Dell touch screen monitor plugged directly into the HDMI port and USB...moreI have displayed the groov View interface using the local browser on a groov EPIC controller across a company network, and used a Dell touch screen monitor plugged directly into the HDMI port and USB port of the groov EPIC. The HDMI connection has a refresh time from 1 to 4 seconds, and the remote browsers refresh is 1 second or less. On another tech support issue, I was told that the local browser that is used for the HDMI connection has a bug and will be updated in the next firmware release of...... <less Unable to install node-red-contrib-azure-iot-hub 0.5.3 in Groov EPIC Forum - Published: Hi, I am working on Groov EPIC PR2 and want to connect to Azure-IOT-hub because my company uses azure for streaming and visualizing sensor data. When I try to install node-red-contrib-azure-iot-hub 0.5...moreHi, I am working on Groov EPIC PR2 and want to connect to Azure-IOT-hub because my company uses azure for streaming and visualizing sensor data. When I try to install node-red-contrib-azure-iot-hub 0.5.3 i got the following error. Can someone help here on this. Error log is added here for reference. 024-03-20T08:16:17.120Z Install : @nodecolor/node-red-contrib-azure-iot-hub 0.5.3 2024-03-20T08:16:18.366Z npm install --no-audit --no-update-notifier --no-fund --save --save-prefix=~ --production --...... <less Groovepic not getting connected with Vi network Forum - Published: In India Vi is a renowned mobile service provider. When I am trying to use the hotspot through Vi network then I am unable to access groovepic at my machine. PFB the IP addresses- Hotspot’s IP address...moreIn India Vi is a renowned mobile service provider. When I am trying to use the hotspot through Vi network then I am unable to access groovepic at my machine. PFB the IP addresses- Hotspot’s IP address(at my laptop accessing this IP)-192.168.116.132 IP address to access groovepic at my laptop-192.168.137.68. When I am accessing 192.168.137.68 at chrome then it throws internet timed out error message. Please suggest as to how to access groovepic at laptop through Vi hotspot... <less Can the AS-i network be connected to the R1 controller? Forum - Published: Hello everyone, one of my customers asked me about AS-i. Can his existing AS-i network be connected to the R1 controller? If it is possible, how can I do it? What equipment needs to be added? There is...moreHello everyone, one of my customers asked me about AS-i. Can his existing AS-i network be connected to the R1 controller? If it is possible, how can I do it? What equipment needs to be added? There is an AS-i master station and more than 20 AS-i actuators and sensors. Thanks!... <less Point I/O for EPIC Forum - Published: I would like to know if there is a product that could be used as a Point I/O (like the Allen Bradley Points I/O) I am using this EPIC processor that must activate more than 30 valves that are like 30...moreI would like to know if there is a product that could be used as a Point I/O (like the Allen Bradley Points I/O) I am using this EPIC processor that must activate more than 30 valves that are like 30 feet away from the device. Another EPIC will not be the best solution. I am looking for this Point I/O so I can communicate with them through ethernet IP (or similar).... <less Is There A Limit to Context Data Storage in Node-RED? Forum - Published: I have finally found a method for passing tags from Node-RED to Ignition Edge to use in Ignition Designer, but it requires storing values as Context Data in Node-RED then calling these values in the...moreI have finally found a method for passing tags from Node-RED to Ignition Edge to use in Ignition Designer, but it requires storing values as Context Data in Node-RED then calling these values in the Address Space of an OPC-UA server node (node-red-contrib-opcua-server). However, I will eventually need to pass a much higher volume of data and I’m wondering if using this method will be an issue if there is a limit to how many values I can store as Context Data.... <less Pointer to an Up Timer Forum - Published: I’ve created a pointer table containing pointers to a series of up timers. Here’s an example of how the table values are assigned, see below. SetUpTimerTarget(60, Timer_sec); ptTimerTable[0] = &Timer...moreI’ve created a pointer table containing pointers to a series of up timers. Here’s an example of how the table values are assigned, see below. SetUpTimerTarget(60, Timer_sec); ptTimerTable[0] = &Timer_sec; I then start the time in later code, see below. StartTimer(*ptTimerTable[0]); When Test Compiling I get the following syntax error. Unable to find variable or command “*ptTimerTable[0]” What am I doing wrong here? Thanks in Advance, DKMarion... <less Can I use Ignition Node-RED module with Ignition Edge Free Trial? Forum - Published: I’m attempting to set up an API Key with the Ignition Node-RED module, but am getting an error that the license is invalid. I can’t tell if this is saying that (a) I can’t use this module with Ignition...moreI’m attempting to set up an API Key with the Ignition Node-RED module, but am getting an error that the license is invalid. I can’t tell if this is saying that (a) I can’t use this module with Ignition Edge unless I have an Ignition Edge license (and am not just using the free trial) or (b) I can’t use this module with Ignition Edge because the module license itself is invalid. image1254×213 9.61 KB Has anyone come across this?... <less PAC 10.5 Analog Input - Moving Average Forum - Published: A simple questions that I cannot find documented (or I didn’t look in the right place). The new Moving Average built into the Analog Inputs can be setup to look at X Number of Samples. What determines...moreA simple questions that I cannot find documented (or I didn’t look in the right place). The new Moving Average built into the Analog Inputs can be setup to look at X Number of Samples. What determines the rate of each sample ? A moving average of 10 samples at 1 sec is very different from a moving average of 10 samples at 100msec - both of which I’ve done in the past via logic. Is it based on every time the configuration reads the point (which may or may not be at a set time base) OR is it based...... <less Page 1 of 128Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
How to start the startegy automatically on power up? Forum - Published: Hello, On a Groov Epic I’d like the strategy runs automatically on power up, with no need to press a button on HMI or with PAC control. I checked the documentation, tried to find something on the forum...moreHello, On a Groov Epic I’d like the strategy runs automatically on power up, with no need to press a button on HMI or with PAC control. I checked the documentation, tried to find something on the forum but can’t get a clear answer. Thanks for your help.... <less Having a hard time with installing Tailscale on EPIC Forum - Published: Hello, I am trying to follow this guide from Corso Systems Corso Systems Tailscale on Opto22 groov Hardware | Corso Systems Corso Systems walks through setting up...moreHello, I am trying to follow this guide from Corso Systems Corso Systems Tailscale on Opto22 groov Hardware | Corso Systems Corso Systems walks through setting up Tailscale on an Opto22 groov RIO. Tailscale is built on the Wireguard framework, but can be easier to configure depending on your IT skillset. And I keep getting this error after I do the wget https://pkgs.tailscale.com/stable/tailscale_1.62.0_arm.tgz Connecting to pkgs.tails...... <less Fail to connect node-red to websocket (postman) Forum - Published: Fail to connect node-red to websocket (postman) because of Error on self signed certificate… Groove Rio, How listen to groove value to websocket… ...Fail to connect node-red to websocket (postman) because of Error on self signed certificate… Groove Rio, How listen to groove value to websocket… ... <less PAC Controller blocking port 22001? Forum - Published: I have a system using a SNAP-PAC-R1 for I/O, using an old program (Lookout by National Instruments) and we want to start using PAC Control instead. So I made a strategy and tried to download it to the...moreI have a system using a SNAP-PAC-R1 for I/O, using an old program (Lookout by National Instruments) and we want to start using PAC Control instead. So I made a strategy and tried to download it to the controller and got an error code -10057. The Ethernet connection is definitely there; I can ping the controller (10.90.150.56) from the PC with PAC Control (10.90.150.2). Both are on the same subnet. I asked my network admin if the switches might be blocking communication through port 22001, and he...... <less Groov View plug in display refresh rate Forum - Published: I have displayed the groov View interface using the local browser on a groov EPIC controller across a company network, and used a Dell touch screen monitor plugged directly into the HDMI port and USB...moreI have displayed the groov View interface using the local browser on a groov EPIC controller across a company network, and used a Dell touch screen monitor plugged directly into the HDMI port and USB port of the groov EPIC. The HDMI connection has a refresh time from 1 to 4 seconds, and the remote browsers refresh is 1 second or less. On another tech support issue, I was told that the local browser that is used for the HDMI connection has a bug and will be updated in the next firmware release of...... <less Unable to install node-red-contrib-azure-iot-hub 0.5.3 in Groov EPIC Forum - Published: Hi, I am working on Groov EPIC PR2 and want to connect to Azure-IOT-hub because my company uses azure for streaming and visualizing sensor data. When I try to install node-red-contrib-azure-iot-hub 0.5...moreHi, I am working on Groov EPIC PR2 and want to connect to Azure-IOT-hub because my company uses azure for streaming and visualizing sensor data. When I try to install node-red-contrib-azure-iot-hub 0.5.3 i got the following error. Can someone help here on this. Error log is added here for reference. 024-03-20T08:16:17.120Z Install : @nodecolor/node-red-contrib-azure-iot-hub 0.5.3 2024-03-20T08:16:18.366Z npm install --no-audit --no-update-notifier --no-fund --save --save-prefix=~ --production --...... <less Groovepic not getting connected with Vi network Forum - Published: In India Vi is a renowned mobile service provider. When I am trying to use the hotspot through Vi network then I am unable to access groovepic at my machine. PFB the IP addresses- Hotspot’s IP address...moreIn India Vi is a renowned mobile service provider. When I am trying to use the hotspot through Vi network then I am unable to access groovepic at my machine. PFB the IP addresses- Hotspot’s IP address(at my laptop accessing this IP)-192.168.116.132 IP address to access groovepic at my laptop-192.168.137.68. When I am accessing 192.168.137.68 at chrome then it throws internet timed out error message. Please suggest as to how to access groovepic at laptop through Vi hotspot... <less Can the AS-i network be connected to the R1 controller? Forum - Published: Hello everyone, one of my customers asked me about AS-i. Can his existing AS-i network be connected to the R1 controller? If it is possible, how can I do it? What equipment needs to be added? There is...moreHello everyone, one of my customers asked me about AS-i. Can his existing AS-i network be connected to the R1 controller? If it is possible, how can I do it? What equipment needs to be added? There is an AS-i master station and more than 20 AS-i actuators and sensors. Thanks!... <less Point I/O for EPIC Forum - Published: I would like to know if there is a product that could be used as a Point I/O (like the Allen Bradley Points I/O) I am using this EPIC processor that must activate more than 30 valves that are like 30...moreI would like to know if there is a product that could be used as a Point I/O (like the Allen Bradley Points I/O) I am using this EPIC processor that must activate more than 30 valves that are like 30 feet away from the device. Another EPIC will not be the best solution. I am looking for this Point I/O so I can communicate with them through ethernet IP (or similar).... <less Is There A Limit to Context Data Storage in Node-RED? Forum - Published: I have finally found a method for passing tags from Node-RED to Ignition Edge to use in Ignition Designer, but it requires storing values as Context Data in Node-RED then calling these values in the...moreI have finally found a method for passing tags from Node-RED to Ignition Edge to use in Ignition Designer, but it requires storing values as Context Data in Node-RED then calling these values in the Address Space of an OPC-UA server node (node-red-contrib-opcua-server). However, I will eventually need to pass a much higher volume of data and I’m wondering if using this method will be an issue if there is a limit to how many values I can store as Context Data.... <less Pointer to an Up Timer Forum - Published: I’ve created a pointer table containing pointers to a series of up timers. Here’s an example of how the table values are assigned, see below. SetUpTimerTarget(60, Timer_sec); ptTimerTable[0] = &Timer...moreI’ve created a pointer table containing pointers to a series of up timers. Here’s an example of how the table values are assigned, see below. SetUpTimerTarget(60, Timer_sec); ptTimerTable[0] = &Timer_sec; I then start the time in later code, see below. StartTimer(*ptTimerTable[0]); When Test Compiling I get the following syntax error. Unable to find variable or command “*ptTimerTable[0]” What am I doing wrong here? Thanks in Advance, DKMarion... <less Can I use Ignition Node-RED module with Ignition Edge Free Trial? Forum - Published: I’m attempting to set up an API Key with the Ignition Node-RED module, but am getting an error that the license is invalid. I can’t tell if this is saying that (a) I can’t use this module with Ignition...moreI’m attempting to set up an API Key with the Ignition Node-RED module, but am getting an error that the license is invalid. I can’t tell if this is saying that (a) I can’t use this module with Ignition Edge unless I have an Ignition Edge license (and am not just using the free trial) or (b) I can’t use this module with Ignition Edge because the module license itself is invalid. image1254×213 9.61 KB Has anyone come across this?... <less PAC 10.5 Analog Input - Moving Average Forum - Published: A simple questions that I cannot find documented (or I didn’t look in the right place). The new Moving Average built into the Analog Inputs can be setup to look at X Number of Samples. What determines...moreA simple questions that I cannot find documented (or I didn’t look in the right place). The new Moving Average built into the Analog Inputs can be setup to look at X Number of Samples. What determines the rate of each sample ? A moving average of 10 samples at 1 sec is very different from a moving average of 10 samples at 100msec - both of which I’ve done in the past via logic. Is it based on every time the configuration reads the point (which may or may not be at a set time base) OR is it based...... <less Page 1 of 128Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Having a hard time with installing Tailscale on EPIC Forum - Published: Hello, I am trying to follow this guide from Corso Systems Corso Systems Tailscale on Opto22 groov Hardware | Corso Systems Corso Systems walks through setting up...moreHello, I am trying to follow this guide from Corso Systems Corso Systems Tailscale on Opto22 groov Hardware | Corso Systems Corso Systems walks through setting up Tailscale on an Opto22 groov RIO. Tailscale is built on the Wireguard framework, but can be easier to configure depending on your IT skillset. And I keep getting this error after I do the wget https://pkgs.tailscale.com/stable/tailscale_1.62.0_arm.tgz Connecting to pkgs.tails...... <less Fail to connect node-red to websocket (postman) Forum - Published: Fail to connect node-red to websocket (postman) because of Error on self signed certificate… Groove Rio, How listen to groove value to websocket… ...Fail to connect node-red to websocket (postman) because of Error on self signed certificate… Groove Rio, How listen to groove value to websocket… ... <less PAC Controller blocking port 22001? Forum - Published: I have a system using a SNAP-PAC-R1 for I/O, using an old program (Lookout by National Instruments) and we want to start using PAC Control instead. So I made a strategy and tried to download it to the...moreI have a system using a SNAP-PAC-R1 for I/O, using an old program (Lookout by National Instruments) and we want to start using PAC Control instead. So I made a strategy and tried to download it to the controller and got an error code -10057. The Ethernet connection is definitely there; I can ping the controller (10.90.150.56) from the PC with PAC Control (10.90.150.2). Both are on the same subnet. I asked my network admin if the switches might be blocking communication through port 22001, and he...... <less Groov View plug in display refresh rate Forum - Published: I have displayed the groov View interface using the local browser on a groov EPIC controller across a company network, and used a Dell touch screen monitor plugged directly into the HDMI port and USB...moreI have displayed the groov View interface using the local browser on a groov EPIC controller across a company network, and used a Dell touch screen monitor plugged directly into the HDMI port and USB port of the groov EPIC. The HDMI connection has a refresh time from 1 to 4 seconds, and the remote browsers refresh is 1 second or less. On another tech support issue, I was told that the local browser that is used for the HDMI connection has a bug and will be updated in the next firmware release of...... <less Unable to install node-red-contrib-azure-iot-hub 0.5.3 in Groov EPIC Forum - Published: Hi, I am working on Groov EPIC PR2 and want to connect to Azure-IOT-hub because my company uses azure for streaming and visualizing sensor data. When I try to install node-red-contrib-azure-iot-hub 0.5...moreHi, I am working on Groov EPIC PR2 and want to connect to Azure-IOT-hub because my company uses azure for streaming and visualizing sensor data. When I try to install node-red-contrib-azure-iot-hub 0.5.3 i got the following error. Can someone help here on this. Error log is added here for reference. 024-03-20T08:16:17.120Z Install : @nodecolor/node-red-contrib-azure-iot-hub 0.5.3 2024-03-20T08:16:18.366Z npm install --no-audit --no-update-notifier --no-fund --save --save-prefix=~ --production --...... <less Groovepic not getting connected with Vi network Forum - Published: In India Vi is a renowned mobile service provider. When I am trying to use the hotspot through Vi network then I am unable to access groovepic at my machine. PFB the IP addresses- Hotspot’s IP address...moreIn India Vi is a renowned mobile service provider. When I am trying to use the hotspot through Vi network then I am unable to access groovepic at my machine. PFB the IP addresses- Hotspot’s IP address(at my laptop accessing this IP)-192.168.116.132 IP address to access groovepic at my laptop-192.168.137.68. When I am accessing 192.168.137.68 at chrome then it throws internet timed out error message. Please suggest as to how to access groovepic at laptop through Vi hotspot... <less Can the AS-i network be connected to the R1 controller? Forum - Published: Hello everyone, one of my customers asked me about AS-i. Can his existing AS-i network be connected to the R1 controller? If it is possible, how can I do it? What equipment needs to be added? There is...moreHello everyone, one of my customers asked me about AS-i. Can his existing AS-i network be connected to the R1 controller? If it is possible, how can I do it? What equipment needs to be added? There is an AS-i master station and more than 20 AS-i actuators and sensors. Thanks!... <less Point I/O for EPIC Forum - Published: I would like to know if there is a product that could be used as a Point I/O (like the Allen Bradley Points I/O) I am using this EPIC processor that must activate more than 30 valves that are like 30...moreI would like to know if there is a product that could be used as a Point I/O (like the Allen Bradley Points I/O) I am using this EPIC processor that must activate more than 30 valves that are like 30 feet away from the device. Another EPIC will not be the best solution. I am looking for this Point I/O so I can communicate with them through ethernet IP (or similar).... <less Is There A Limit to Context Data Storage in Node-RED? Forum - Published: I have finally found a method for passing tags from Node-RED to Ignition Edge to use in Ignition Designer, but it requires storing values as Context Data in Node-RED then calling these values in the...moreI have finally found a method for passing tags from Node-RED to Ignition Edge to use in Ignition Designer, but it requires storing values as Context Data in Node-RED then calling these values in the Address Space of an OPC-UA server node (node-red-contrib-opcua-server). However, I will eventually need to pass a much higher volume of data and I’m wondering if using this method will be an issue if there is a limit to how many values I can store as Context Data.... <less Pointer to an Up Timer Forum - Published: I’ve created a pointer table containing pointers to a series of up timers. Here’s an example of how the table values are assigned, see below. SetUpTimerTarget(60, Timer_sec); ptTimerTable[0] = &Timer...moreI’ve created a pointer table containing pointers to a series of up timers. Here’s an example of how the table values are assigned, see below. SetUpTimerTarget(60, Timer_sec); ptTimerTable[0] = &Timer_sec; I then start the time in later code, see below. StartTimer(*ptTimerTable[0]); When Test Compiling I get the following syntax error. Unable to find variable or command “*ptTimerTable[0]” What am I doing wrong here? Thanks in Advance, DKMarion... <less Can I use Ignition Node-RED module with Ignition Edge Free Trial? Forum - Published: I’m attempting to set up an API Key with the Ignition Node-RED module, but am getting an error that the license is invalid. I can’t tell if this is saying that (a) I can’t use this module with Ignition...moreI’m attempting to set up an API Key with the Ignition Node-RED module, but am getting an error that the license is invalid. I can’t tell if this is saying that (a) I can’t use this module with Ignition Edge unless I have an Ignition Edge license (and am not just using the free trial) or (b) I can’t use this module with Ignition Edge because the module license itself is invalid. image1254×213 9.61 KB Has anyone come across this?... <less PAC 10.5 Analog Input - Moving Average Forum - Published: A simple questions that I cannot find documented (or I didn’t look in the right place). The new Moving Average built into the Analog Inputs can be setup to look at X Number of Samples. What determines...moreA simple questions that I cannot find documented (or I didn’t look in the right place). The new Moving Average built into the Analog Inputs can be setup to look at X Number of Samples. What determines the rate of each sample ? A moving average of 10 samples at 1 sec is very different from a moving average of 10 samples at 100msec - both of which I’ve done in the past via logic. Is it based on every time the configuration reads the point (which may or may not be at a set time base) OR is it based...... <less Page 1 of 128Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Fail to connect node-red to websocket (postman) Forum - Published: Fail to connect node-red to websocket (postman) because of Error on self signed certificate… Groove Rio, How listen to groove value to websocket… ...Fail to connect node-red to websocket (postman) because of Error on self signed certificate… Groove Rio, How listen to groove value to websocket… ... <less PAC Controller blocking port 22001? Forum - Published: I have a system using a SNAP-PAC-R1 for I/O, using an old program (Lookout by National Instruments) and we want to start using PAC Control instead. So I made a strategy and tried to download it to the...moreI have a system using a SNAP-PAC-R1 for I/O, using an old program (Lookout by National Instruments) and we want to start using PAC Control instead. So I made a strategy and tried to download it to the controller and got an error code -10057. The Ethernet connection is definitely there; I can ping the controller (10.90.150.56) from the PC with PAC Control (10.90.150.2). Both are on the same subnet. I asked my network admin if the switches might be blocking communication through port 22001, and he...... <less Groov View plug in display refresh rate Forum - Published: I have displayed the groov View interface using the local browser on a groov EPIC controller across a company network, and used a Dell touch screen monitor plugged directly into the HDMI port and USB...moreI have displayed the groov View interface using the local browser on a groov EPIC controller across a company network, and used a Dell touch screen monitor plugged directly into the HDMI port and USB port of the groov EPIC. The HDMI connection has a refresh time from 1 to 4 seconds, and the remote browsers refresh is 1 second or less. On another tech support issue, I was told that the local browser that is used for the HDMI connection has a bug and will be updated in the next firmware release of...... <less Unable to install node-red-contrib-azure-iot-hub 0.5.3 in Groov EPIC Forum - Published: Hi, I am working on Groov EPIC PR2 and want to connect to Azure-IOT-hub because my company uses azure for streaming and visualizing sensor data. When I try to install node-red-contrib-azure-iot-hub 0.5...moreHi, I am working on Groov EPIC PR2 and want to connect to Azure-IOT-hub because my company uses azure for streaming and visualizing sensor data. When I try to install node-red-contrib-azure-iot-hub 0.5.3 i got the following error. Can someone help here on this. Error log is added here for reference. 024-03-20T08:16:17.120Z Install : @nodecolor/node-red-contrib-azure-iot-hub 0.5.3 2024-03-20T08:16:18.366Z npm install --no-audit --no-update-notifier --no-fund --save --save-prefix=~ --production --...... <less Groovepic not getting connected with Vi network Forum - Published: In India Vi is a renowned mobile service provider. When I am trying to use the hotspot through Vi network then I am unable to access groovepic at my machine. PFB the IP addresses- Hotspot’s IP address...moreIn India Vi is a renowned mobile service provider. When I am trying to use the hotspot through Vi network then I am unable to access groovepic at my machine. PFB the IP addresses- Hotspot’s IP address(at my laptop accessing this IP)-192.168.116.132 IP address to access groovepic at my laptop-192.168.137.68. When I am accessing 192.168.137.68 at chrome then it throws internet timed out error message. Please suggest as to how to access groovepic at laptop through Vi hotspot... <less Can the AS-i network be connected to the R1 controller? Forum - Published: Hello everyone, one of my customers asked me about AS-i. Can his existing AS-i network be connected to the R1 controller? If it is possible, how can I do it? What equipment needs to be added? There is...moreHello everyone, one of my customers asked me about AS-i. Can his existing AS-i network be connected to the R1 controller? If it is possible, how can I do it? What equipment needs to be added? There is an AS-i master station and more than 20 AS-i actuators and sensors. Thanks!... <less Point I/O for EPIC Forum - Published: I would like to know if there is a product that could be used as a Point I/O (like the Allen Bradley Points I/O) I am using this EPIC processor that must activate more than 30 valves that are like 30...moreI would like to know if there is a product that could be used as a Point I/O (like the Allen Bradley Points I/O) I am using this EPIC processor that must activate more than 30 valves that are like 30 feet away from the device. Another EPIC will not be the best solution. I am looking for this Point I/O so I can communicate with them through ethernet IP (or similar).... <less Is There A Limit to Context Data Storage in Node-RED? Forum - Published: I have finally found a method for passing tags from Node-RED to Ignition Edge to use in Ignition Designer, but it requires storing values as Context Data in Node-RED then calling these values in the...moreI have finally found a method for passing tags from Node-RED to Ignition Edge to use in Ignition Designer, but it requires storing values as Context Data in Node-RED then calling these values in the Address Space of an OPC-UA server node (node-red-contrib-opcua-server). However, I will eventually need to pass a much higher volume of data and I’m wondering if using this method will be an issue if there is a limit to how many values I can store as Context Data.... <less Pointer to an Up Timer Forum - Published: I’ve created a pointer table containing pointers to a series of up timers. Here’s an example of how the table values are assigned, see below. SetUpTimerTarget(60, Timer_sec); ptTimerTable[0] = &Timer...moreI’ve created a pointer table containing pointers to a series of up timers. Here’s an example of how the table values are assigned, see below. SetUpTimerTarget(60, Timer_sec); ptTimerTable[0] = &Timer_sec; I then start the time in later code, see below. StartTimer(*ptTimerTable[0]); When Test Compiling I get the following syntax error. Unable to find variable or command “*ptTimerTable[0]” What am I doing wrong here? Thanks in Advance, DKMarion... <less Can I use Ignition Node-RED module with Ignition Edge Free Trial? Forum - Published: I’m attempting to set up an API Key with the Ignition Node-RED module, but am getting an error that the license is invalid. I can’t tell if this is saying that (a) I can’t use this module with Ignition...moreI’m attempting to set up an API Key with the Ignition Node-RED module, but am getting an error that the license is invalid. I can’t tell if this is saying that (a) I can’t use this module with Ignition Edge unless I have an Ignition Edge license (and am not just using the free trial) or (b) I can’t use this module with Ignition Edge because the module license itself is invalid. image1254×213 9.61 KB Has anyone come across this?... <less PAC 10.5 Analog Input - Moving Average Forum - Published: A simple questions that I cannot find documented (or I didn’t look in the right place). The new Moving Average built into the Analog Inputs can be setup to look at X Number of Samples. What determines...moreA simple questions that I cannot find documented (or I didn’t look in the right place). The new Moving Average built into the Analog Inputs can be setup to look at X Number of Samples. What determines the rate of each sample ? A moving average of 10 samples at 1 sec is very different from a moving average of 10 samples at 100msec - both of which I’ve done in the past via logic. Is it based on every time the configuration reads the point (which may or may not be at a set time base) OR is it based...... <less Page 1 of 128Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
PAC Controller blocking port 22001? Forum - Published: I have a system using a SNAP-PAC-R1 for I/O, using an old program (Lookout by National Instruments) and we want to start using PAC Control instead. So I made a strategy and tried to download it to the...moreI have a system using a SNAP-PAC-R1 for I/O, using an old program (Lookout by National Instruments) and we want to start using PAC Control instead. So I made a strategy and tried to download it to the controller and got an error code -10057. The Ethernet connection is definitely there; I can ping the controller (10.90.150.56) from the PC with PAC Control (10.90.150.2). Both are on the same subnet. I asked my network admin if the switches might be blocking communication through port 22001, and he...... <less Groov View plug in display refresh rate Forum - Published: I have displayed the groov View interface using the local browser on a groov EPIC controller across a company network, and used a Dell touch screen monitor plugged directly into the HDMI port and USB...moreI have displayed the groov View interface using the local browser on a groov EPIC controller across a company network, and used a Dell touch screen monitor plugged directly into the HDMI port and USB port of the groov EPIC. The HDMI connection has a refresh time from 1 to 4 seconds, and the remote browsers refresh is 1 second or less. On another tech support issue, I was told that the local browser that is used for the HDMI connection has a bug and will be updated in the next firmware release of...... <less Unable to install node-red-contrib-azure-iot-hub 0.5.3 in Groov EPIC Forum - Published: Hi, I am working on Groov EPIC PR2 and want to connect to Azure-IOT-hub because my company uses azure for streaming and visualizing sensor data. When I try to install node-red-contrib-azure-iot-hub 0.5...moreHi, I am working on Groov EPIC PR2 and want to connect to Azure-IOT-hub because my company uses azure for streaming and visualizing sensor data. When I try to install node-red-contrib-azure-iot-hub 0.5.3 i got the following error. Can someone help here on this. Error log is added here for reference. 024-03-20T08:16:17.120Z Install : @nodecolor/node-red-contrib-azure-iot-hub 0.5.3 2024-03-20T08:16:18.366Z npm install --no-audit --no-update-notifier --no-fund --save --save-prefix=~ --production --...... <less Groovepic not getting connected with Vi network Forum - Published: In India Vi is a renowned mobile service provider. When I am trying to use the hotspot through Vi network then I am unable to access groovepic at my machine. PFB the IP addresses- Hotspot’s IP address...moreIn India Vi is a renowned mobile service provider. When I am trying to use the hotspot through Vi network then I am unable to access groovepic at my machine. PFB the IP addresses- Hotspot’s IP address(at my laptop accessing this IP)-192.168.116.132 IP address to access groovepic at my laptop-192.168.137.68. When I am accessing 192.168.137.68 at chrome then it throws internet timed out error message. Please suggest as to how to access groovepic at laptop through Vi hotspot... <less Can the AS-i network be connected to the R1 controller? Forum - Published: Hello everyone, one of my customers asked me about AS-i. Can his existing AS-i network be connected to the R1 controller? If it is possible, how can I do it? What equipment needs to be added? There is...moreHello everyone, one of my customers asked me about AS-i. Can his existing AS-i network be connected to the R1 controller? If it is possible, how can I do it? What equipment needs to be added? There is an AS-i master station and more than 20 AS-i actuators and sensors. Thanks!... <less Point I/O for EPIC Forum - Published: I would like to know if there is a product that could be used as a Point I/O (like the Allen Bradley Points I/O) I am using this EPIC processor that must activate more than 30 valves that are like 30...moreI would like to know if there is a product that could be used as a Point I/O (like the Allen Bradley Points I/O) I am using this EPIC processor that must activate more than 30 valves that are like 30 feet away from the device. Another EPIC will not be the best solution. I am looking for this Point I/O so I can communicate with them through ethernet IP (or similar).... <less Is There A Limit to Context Data Storage in Node-RED? Forum - Published: I have finally found a method for passing tags from Node-RED to Ignition Edge to use in Ignition Designer, but it requires storing values as Context Data in Node-RED then calling these values in the...moreI have finally found a method for passing tags from Node-RED to Ignition Edge to use in Ignition Designer, but it requires storing values as Context Data in Node-RED then calling these values in the Address Space of an OPC-UA server node (node-red-contrib-opcua-server). However, I will eventually need to pass a much higher volume of data and I’m wondering if using this method will be an issue if there is a limit to how many values I can store as Context Data.... <less Pointer to an Up Timer Forum - Published: I’ve created a pointer table containing pointers to a series of up timers. Here’s an example of how the table values are assigned, see below. SetUpTimerTarget(60, Timer_sec); ptTimerTable[0] = &Timer...moreI’ve created a pointer table containing pointers to a series of up timers. Here’s an example of how the table values are assigned, see below. SetUpTimerTarget(60, Timer_sec); ptTimerTable[0] = &Timer_sec; I then start the time in later code, see below. StartTimer(*ptTimerTable[0]); When Test Compiling I get the following syntax error. Unable to find variable or command “*ptTimerTable[0]” What am I doing wrong here? Thanks in Advance, DKMarion... <less Can I use Ignition Node-RED module with Ignition Edge Free Trial? Forum - Published: I’m attempting to set up an API Key with the Ignition Node-RED module, but am getting an error that the license is invalid. I can’t tell if this is saying that (a) I can’t use this module with Ignition...moreI’m attempting to set up an API Key with the Ignition Node-RED module, but am getting an error that the license is invalid. I can’t tell if this is saying that (a) I can’t use this module with Ignition Edge unless I have an Ignition Edge license (and am not just using the free trial) or (b) I can’t use this module with Ignition Edge because the module license itself is invalid. image1254×213 9.61 KB Has anyone come across this?... <less PAC 10.5 Analog Input - Moving Average Forum - Published: A simple questions that I cannot find documented (or I didn’t look in the right place). The new Moving Average built into the Analog Inputs can be setup to look at X Number of Samples. What determines...moreA simple questions that I cannot find documented (or I didn’t look in the right place). The new Moving Average built into the Analog Inputs can be setup to look at X Number of Samples. What determines the rate of each sample ? A moving average of 10 samples at 1 sec is very different from a moving average of 10 samples at 100msec - both of which I’ve done in the past via logic. Is it based on every time the configuration reads the point (which may or may not be at a set time base) OR is it based...... <less Page 1 of 128Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Groov View plug in display refresh rate Forum - Published: I have displayed the groov View interface using the local browser on a groov EPIC controller across a company network, and used a Dell touch screen monitor plugged directly into the HDMI port and USB...moreI have displayed the groov View interface using the local browser on a groov EPIC controller across a company network, and used a Dell touch screen monitor plugged directly into the HDMI port and USB port of the groov EPIC. The HDMI connection has a refresh time from 1 to 4 seconds, and the remote browsers refresh is 1 second or less. On another tech support issue, I was told that the local browser that is used for the HDMI connection has a bug and will be updated in the next firmware release of...... <less Unable to install node-red-contrib-azure-iot-hub 0.5.3 in Groov EPIC Forum - Published: Hi, I am working on Groov EPIC PR2 and want to connect to Azure-IOT-hub because my company uses azure for streaming and visualizing sensor data. When I try to install node-red-contrib-azure-iot-hub 0.5...moreHi, I am working on Groov EPIC PR2 and want to connect to Azure-IOT-hub because my company uses azure for streaming and visualizing sensor data. When I try to install node-red-contrib-azure-iot-hub 0.5.3 i got the following error. Can someone help here on this. Error log is added here for reference. 024-03-20T08:16:17.120Z Install : @nodecolor/node-red-contrib-azure-iot-hub 0.5.3 2024-03-20T08:16:18.366Z npm install --no-audit --no-update-notifier --no-fund --save --save-prefix=~ --production --...... <less Groovepic not getting connected with Vi network Forum - Published: In India Vi is a renowned mobile service provider. When I am trying to use the hotspot through Vi network then I am unable to access groovepic at my machine. PFB the IP addresses- Hotspot’s IP address...moreIn India Vi is a renowned mobile service provider. When I am trying to use the hotspot through Vi network then I am unable to access groovepic at my machine. PFB the IP addresses- Hotspot’s IP address(at my laptop accessing this IP)-192.168.116.132 IP address to access groovepic at my laptop-192.168.137.68. When I am accessing 192.168.137.68 at chrome then it throws internet timed out error message. Please suggest as to how to access groovepic at laptop through Vi hotspot... <less Can the AS-i network be connected to the R1 controller? Forum - Published: Hello everyone, one of my customers asked me about AS-i. Can his existing AS-i network be connected to the R1 controller? If it is possible, how can I do it? What equipment needs to be added? There is...moreHello everyone, one of my customers asked me about AS-i. Can his existing AS-i network be connected to the R1 controller? If it is possible, how can I do it? What equipment needs to be added? There is an AS-i master station and more than 20 AS-i actuators and sensors. Thanks!... <less Point I/O for EPIC Forum - Published: I would like to know if there is a product that could be used as a Point I/O (like the Allen Bradley Points I/O) I am using this EPIC processor that must activate more than 30 valves that are like 30...moreI would like to know if there is a product that could be used as a Point I/O (like the Allen Bradley Points I/O) I am using this EPIC processor that must activate more than 30 valves that are like 30 feet away from the device. Another EPIC will not be the best solution. I am looking for this Point I/O so I can communicate with them through ethernet IP (or similar).... <less Is There A Limit to Context Data Storage in Node-RED? Forum - Published: I have finally found a method for passing tags from Node-RED to Ignition Edge to use in Ignition Designer, but it requires storing values as Context Data in Node-RED then calling these values in the...moreI have finally found a method for passing tags from Node-RED to Ignition Edge to use in Ignition Designer, but it requires storing values as Context Data in Node-RED then calling these values in the Address Space of an OPC-UA server node (node-red-contrib-opcua-server). However, I will eventually need to pass a much higher volume of data and I’m wondering if using this method will be an issue if there is a limit to how many values I can store as Context Data.... <less Pointer to an Up Timer Forum - Published: I’ve created a pointer table containing pointers to a series of up timers. Here’s an example of how the table values are assigned, see below. SetUpTimerTarget(60, Timer_sec); ptTimerTable[0] = &Timer...moreI’ve created a pointer table containing pointers to a series of up timers. Here’s an example of how the table values are assigned, see below. SetUpTimerTarget(60, Timer_sec); ptTimerTable[0] = &Timer_sec; I then start the time in later code, see below. StartTimer(*ptTimerTable[0]); When Test Compiling I get the following syntax error. Unable to find variable or command “*ptTimerTable[0]” What am I doing wrong here? Thanks in Advance, DKMarion... <less Can I use Ignition Node-RED module with Ignition Edge Free Trial? Forum - Published: I’m attempting to set up an API Key with the Ignition Node-RED module, but am getting an error that the license is invalid. I can’t tell if this is saying that (a) I can’t use this module with Ignition...moreI’m attempting to set up an API Key with the Ignition Node-RED module, but am getting an error that the license is invalid. I can’t tell if this is saying that (a) I can’t use this module with Ignition Edge unless I have an Ignition Edge license (and am not just using the free trial) or (b) I can’t use this module with Ignition Edge because the module license itself is invalid. image1254×213 9.61 KB Has anyone come across this?... <less PAC 10.5 Analog Input - Moving Average Forum - Published: A simple questions that I cannot find documented (or I didn’t look in the right place). The new Moving Average built into the Analog Inputs can be setup to look at X Number of Samples. What determines...moreA simple questions that I cannot find documented (or I didn’t look in the right place). The new Moving Average built into the Analog Inputs can be setup to look at X Number of Samples. What determines the rate of each sample ? A moving average of 10 samples at 1 sec is very different from a moving average of 10 samples at 100msec - both of which I’ve done in the past via logic. Is it based on every time the configuration reads the point (which may or may not be at a set time base) OR is it based...... <less Page 1 of 128Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Unable to install node-red-contrib-azure-iot-hub 0.5.3 in Groov EPIC Forum - Published: Hi, I am working on Groov EPIC PR2 and want to connect to Azure-IOT-hub because my company uses azure for streaming and visualizing sensor data. When I try to install node-red-contrib-azure-iot-hub 0.5...moreHi, I am working on Groov EPIC PR2 and want to connect to Azure-IOT-hub because my company uses azure for streaming and visualizing sensor data. When I try to install node-red-contrib-azure-iot-hub 0.5.3 i got the following error. Can someone help here on this. Error log is added here for reference. 024-03-20T08:16:17.120Z Install : @nodecolor/node-red-contrib-azure-iot-hub 0.5.3 2024-03-20T08:16:18.366Z npm install --no-audit --no-update-notifier --no-fund --save --save-prefix=~ --production --...... <less Groovepic not getting connected with Vi network Forum - Published: In India Vi is a renowned mobile service provider. When I am trying to use the hotspot through Vi network then I am unable to access groovepic at my machine. PFB the IP addresses- Hotspot’s IP address...moreIn India Vi is a renowned mobile service provider. When I am trying to use the hotspot through Vi network then I am unable to access groovepic at my machine. PFB the IP addresses- Hotspot’s IP address(at my laptop accessing this IP)-192.168.116.132 IP address to access groovepic at my laptop-192.168.137.68. When I am accessing 192.168.137.68 at chrome then it throws internet timed out error message. Please suggest as to how to access groovepic at laptop through Vi hotspot... <less Can the AS-i network be connected to the R1 controller? Forum - Published: Hello everyone, one of my customers asked me about AS-i. Can his existing AS-i network be connected to the R1 controller? If it is possible, how can I do it? What equipment needs to be added? There is...moreHello everyone, one of my customers asked me about AS-i. Can his existing AS-i network be connected to the R1 controller? If it is possible, how can I do it? What equipment needs to be added? There is an AS-i master station and more than 20 AS-i actuators and sensors. Thanks!... <less Point I/O for EPIC Forum - Published: I would like to know if there is a product that could be used as a Point I/O (like the Allen Bradley Points I/O) I am using this EPIC processor that must activate more than 30 valves that are like 30...moreI would like to know if there is a product that could be used as a Point I/O (like the Allen Bradley Points I/O) I am using this EPIC processor that must activate more than 30 valves that are like 30 feet away from the device. Another EPIC will not be the best solution. I am looking for this Point I/O so I can communicate with them through ethernet IP (or similar).... <less Is There A Limit to Context Data Storage in Node-RED? Forum - Published: I have finally found a method for passing tags from Node-RED to Ignition Edge to use in Ignition Designer, but it requires storing values as Context Data in Node-RED then calling these values in the...moreI have finally found a method for passing tags from Node-RED to Ignition Edge to use in Ignition Designer, but it requires storing values as Context Data in Node-RED then calling these values in the Address Space of an OPC-UA server node (node-red-contrib-opcua-server). However, I will eventually need to pass a much higher volume of data and I’m wondering if using this method will be an issue if there is a limit to how many values I can store as Context Data.... <less Pointer to an Up Timer Forum - Published: I’ve created a pointer table containing pointers to a series of up timers. Here’s an example of how the table values are assigned, see below. SetUpTimerTarget(60, Timer_sec); ptTimerTable[0] = &Timer...moreI’ve created a pointer table containing pointers to a series of up timers. Here’s an example of how the table values are assigned, see below. SetUpTimerTarget(60, Timer_sec); ptTimerTable[0] = &Timer_sec; I then start the time in later code, see below. StartTimer(*ptTimerTable[0]); When Test Compiling I get the following syntax error. Unable to find variable or command “*ptTimerTable[0]” What am I doing wrong here? Thanks in Advance, DKMarion... <less Can I use Ignition Node-RED module with Ignition Edge Free Trial? Forum - Published: I’m attempting to set up an API Key with the Ignition Node-RED module, but am getting an error that the license is invalid. I can’t tell if this is saying that (a) I can’t use this module with Ignition...moreI’m attempting to set up an API Key with the Ignition Node-RED module, but am getting an error that the license is invalid. I can’t tell if this is saying that (a) I can’t use this module with Ignition Edge unless I have an Ignition Edge license (and am not just using the free trial) or (b) I can’t use this module with Ignition Edge because the module license itself is invalid. image1254×213 9.61 KB Has anyone come across this?... <less PAC 10.5 Analog Input - Moving Average Forum - Published: A simple questions that I cannot find documented (or I didn’t look in the right place). The new Moving Average built into the Analog Inputs can be setup to look at X Number of Samples. What determines...moreA simple questions that I cannot find documented (or I didn’t look in the right place). The new Moving Average built into the Analog Inputs can be setup to look at X Number of Samples. What determines the rate of each sample ? A moving average of 10 samples at 1 sec is very different from a moving average of 10 samples at 100msec - both of which I’ve done in the past via logic. Is it based on every time the configuration reads the point (which may or may not be at a set time base) OR is it based...... <less Page 1 of 128Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Groovepic not getting connected with Vi network Forum - Published: In India Vi is a renowned mobile service provider. When I am trying to use the hotspot through Vi network then I am unable to access groovepic at my machine. PFB the IP addresses- Hotspot’s IP address...moreIn India Vi is a renowned mobile service provider. When I am trying to use the hotspot through Vi network then I am unable to access groovepic at my machine. PFB the IP addresses- Hotspot’s IP address(at my laptop accessing this IP)-192.168.116.132 IP address to access groovepic at my laptop-192.168.137.68. When I am accessing 192.168.137.68 at chrome then it throws internet timed out error message. Please suggest as to how to access groovepic at laptop through Vi hotspot... <less Can the AS-i network be connected to the R1 controller? Forum - Published: Hello everyone, one of my customers asked me about AS-i. Can his existing AS-i network be connected to the R1 controller? If it is possible, how can I do it? What equipment needs to be added? There is...moreHello everyone, one of my customers asked me about AS-i. Can his existing AS-i network be connected to the R1 controller? If it is possible, how can I do it? What equipment needs to be added? There is an AS-i master station and more than 20 AS-i actuators and sensors. Thanks!... <less Point I/O for EPIC Forum - Published: I would like to know if there is a product that could be used as a Point I/O (like the Allen Bradley Points I/O) I am using this EPIC processor that must activate more than 30 valves that are like 30...moreI would like to know if there is a product that could be used as a Point I/O (like the Allen Bradley Points I/O) I am using this EPIC processor that must activate more than 30 valves that are like 30 feet away from the device. Another EPIC will not be the best solution. I am looking for this Point I/O so I can communicate with them through ethernet IP (or similar).... <less Is There A Limit to Context Data Storage in Node-RED? Forum - Published: I have finally found a method for passing tags from Node-RED to Ignition Edge to use in Ignition Designer, but it requires storing values as Context Data in Node-RED then calling these values in the...moreI have finally found a method for passing tags from Node-RED to Ignition Edge to use in Ignition Designer, but it requires storing values as Context Data in Node-RED then calling these values in the Address Space of an OPC-UA server node (node-red-contrib-opcua-server). However, I will eventually need to pass a much higher volume of data and I’m wondering if using this method will be an issue if there is a limit to how many values I can store as Context Data.... <less Pointer to an Up Timer Forum - Published: I’ve created a pointer table containing pointers to a series of up timers. Here’s an example of how the table values are assigned, see below. SetUpTimerTarget(60, Timer_sec); ptTimerTable[0] = &Timer...moreI’ve created a pointer table containing pointers to a series of up timers. Here’s an example of how the table values are assigned, see below. SetUpTimerTarget(60, Timer_sec); ptTimerTable[0] = &Timer_sec; I then start the time in later code, see below. StartTimer(*ptTimerTable[0]); When Test Compiling I get the following syntax error. Unable to find variable or command “*ptTimerTable[0]” What am I doing wrong here? Thanks in Advance, DKMarion... <less Can I use Ignition Node-RED module with Ignition Edge Free Trial? Forum - Published: I’m attempting to set up an API Key with the Ignition Node-RED module, but am getting an error that the license is invalid. I can’t tell if this is saying that (a) I can’t use this module with Ignition...moreI’m attempting to set up an API Key with the Ignition Node-RED module, but am getting an error that the license is invalid. I can’t tell if this is saying that (a) I can’t use this module with Ignition Edge unless I have an Ignition Edge license (and am not just using the free trial) or (b) I can’t use this module with Ignition Edge because the module license itself is invalid. image1254×213 9.61 KB Has anyone come across this?... <less PAC 10.5 Analog Input - Moving Average Forum - Published: A simple questions that I cannot find documented (or I didn’t look in the right place). The new Moving Average built into the Analog Inputs can be setup to look at X Number of Samples. What determines...moreA simple questions that I cannot find documented (or I didn’t look in the right place). The new Moving Average built into the Analog Inputs can be setup to look at X Number of Samples. What determines the rate of each sample ? A moving average of 10 samples at 1 sec is very different from a moving average of 10 samples at 100msec - both of which I’ve done in the past via logic. Is it based on every time the configuration reads the point (which may or may not be at a set time base) OR is it based...... <less Page 1 of 128Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Can the AS-i network be connected to the R1 controller? Forum - Published: Hello everyone, one of my customers asked me about AS-i. Can his existing AS-i network be connected to the R1 controller? If it is possible, how can I do it? What equipment needs to be added? There is...moreHello everyone, one of my customers asked me about AS-i. Can his existing AS-i network be connected to the R1 controller? If it is possible, how can I do it? What equipment needs to be added? There is an AS-i master station and more than 20 AS-i actuators and sensors. Thanks!... <less Point I/O for EPIC Forum - Published: I would like to know if there is a product that could be used as a Point I/O (like the Allen Bradley Points I/O) I am using this EPIC processor that must activate more than 30 valves that are like 30...moreI would like to know if there is a product that could be used as a Point I/O (like the Allen Bradley Points I/O) I am using this EPIC processor that must activate more than 30 valves that are like 30 feet away from the device. Another EPIC will not be the best solution. I am looking for this Point I/O so I can communicate with them through ethernet IP (or similar).... <less Is There A Limit to Context Data Storage in Node-RED? Forum - Published: I have finally found a method for passing tags from Node-RED to Ignition Edge to use in Ignition Designer, but it requires storing values as Context Data in Node-RED then calling these values in the...moreI have finally found a method for passing tags from Node-RED to Ignition Edge to use in Ignition Designer, but it requires storing values as Context Data in Node-RED then calling these values in the Address Space of an OPC-UA server node (node-red-contrib-opcua-server). However, I will eventually need to pass a much higher volume of data and I’m wondering if using this method will be an issue if there is a limit to how many values I can store as Context Data.... <less Pointer to an Up Timer Forum - Published: I’ve created a pointer table containing pointers to a series of up timers. Here’s an example of how the table values are assigned, see below. SetUpTimerTarget(60, Timer_sec); ptTimerTable[0] = &Timer...moreI’ve created a pointer table containing pointers to a series of up timers. Here’s an example of how the table values are assigned, see below. SetUpTimerTarget(60, Timer_sec); ptTimerTable[0] = &Timer_sec; I then start the time in later code, see below. StartTimer(*ptTimerTable[0]); When Test Compiling I get the following syntax error. Unable to find variable or command “*ptTimerTable[0]” What am I doing wrong here? Thanks in Advance, DKMarion... <less Can I use Ignition Node-RED module with Ignition Edge Free Trial? Forum - Published: I’m attempting to set up an API Key with the Ignition Node-RED module, but am getting an error that the license is invalid. I can’t tell if this is saying that (a) I can’t use this module with Ignition...moreI’m attempting to set up an API Key with the Ignition Node-RED module, but am getting an error that the license is invalid. I can’t tell if this is saying that (a) I can’t use this module with Ignition Edge unless I have an Ignition Edge license (and am not just using the free trial) or (b) I can’t use this module with Ignition Edge because the module license itself is invalid. image1254×213 9.61 KB Has anyone come across this?... <less PAC 10.5 Analog Input - Moving Average Forum - Published: A simple questions that I cannot find documented (or I didn’t look in the right place). The new Moving Average built into the Analog Inputs can be setup to look at X Number of Samples. What determines...moreA simple questions that I cannot find documented (or I didn’t look in the right place). The new Moving Average built into the Analog Inputs can be setup to look at X Number of Samples. What determines the rate of each sample ? A moving average of 10 samples at 1 sec is very different from a moving average of 10 samples at 100msec - both of which I’ve done in the past via logic. Is it based on every time the configuration reads the point (which may or may not be at a set time base) OR is it based...... <less Page 1 of 128Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Point I/O for EPIC Forum - Published: I would like to know if there is a product that could be used as a Point I/O (like the Allen Bradley Points I/O) I am using this EPIC processor that must activate more than 30 valves that are like 30...moreI would like to know if there is a product that could be used as a Point I/O (like the Allen Bradley Points I/O) I am using this EPIC processor that must activate more than 30 valves that are like 30 feet away from the device. Another EPIC will not be the best solution. I am looking for this Point I/O so I can communicate with them through ethernet IP (or similar).... <less Is There A Limit to Context Data Storage in Node-RED? Forum - Published: I have finally found a method for passing tags from Node-RED to Ignition Edge to use in Ignition Designer, but it requires storing values as Context Data in Node-RED then calling these values in the...moreI have finally found a method for passing tags from Node-RED to Ignition Edge to use in Ignition Designer, but it requires storing values as Context Data in Node-RED then calling these values in the Address Space of an OPC-UA server node (node-red-contrib-opcua-server). However, I will eventually need to pass a much higher volume of data and I’m wondering if using this method will be an issue if there is a limit to how many values I can store as Context Data.... <less Pointer to an Up Timer Forum - Published: I’ve created a pointer table containing pointers to a series of up timers. Here’s an example of how the table values are assigned, see below. SetUpTimerTarget(60, Timer_sec); ptTimerTable[0] = &Timer...moreI’ve created a pointer table containing pointers to a series of up timers. Here’s an example of how the table values are assigned, see below. SetUpTimerTarget(60, Timer_sec); ptTimerTable[0] = &Timer_sec; I then start the time in later code, see below. StartTimer(*ptTimerTable[0]); When Test Compiling I get the following syntax error. Unable to find variable or command “*ptTimerTable[0]” What am I doing wrong here? Thanks in Advance, DKMarion... <less Can I use Ignition Node-RED module with Ignition Edge Free Trial? Forum - Published: I’m attempting to set up an API Key with the Ignition Node-RED module, but am getting an error that the license is invalid. I can’t tell if this is saying that (a) I can’t use this module with Ignition...moreI’m attempting to set up an API Key with the Ignition Node-RED module, but am getting an error that the license is invalid. I can’t tell if this is saying that (a) I can’t use this module with Ignition Edge unless I have an Ignition Edge license (and am not just using the free trial) or (b) I can’t use this module with Ignition Edge because the module license itself is invalid. image1254×213 9.61 KB Has anyone come across this?... <less PAC 10.5 Analog Input - Moving Average Forum - Published: A simple questions that I cannot find documented (or I didn’t look in the right place). The new Moving Average built into the Analog Inputs can be setup to look at X Number of Samples. What determines...moreA simple questions that I cannot find documented (or I didn’t look in the right place). The new Moving Average built into the Analog Inputs can be setup to look at X Number of Samples. What determines the rate of each sample ? A moving average of 10 samples at 1 sec is very different from a moving average of 10 samples at 100msec - both of which I’ve done in the past via logic. Is it based on every time the configuration reads the point (which may or may not be at a set time base) OR is it based...... <less Page 1 of 128Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Is There A Limit to Context Data Storage in Node-RED? Forum - Published: I have finally found a method for passing tags from Node-RED to Ignition Edge to use in Ignition Designer, but it requires storing values as Context Data in Node-RED then calling these values in the...moreI have finally found a method for passing tags from Node-RED to Ignition Edge to use in Ignition Designer, but it requires storing values as Context Data in Node-RED then calling these values in the Address Space of an OPC-UA server node (node-red-contrib-opcua-server). However, I will eventually need to pass a much higher volume of data and I’m wondering if using this method will be an issue if there is a limit to how many values I can store as Context Data.... <less Pointer to an Up Timer Forum - Published: I’ve created a pointer table containing pointers to a series of up timers. Here’s an example of how the table values are assigned, see below. SetUpTimerTarget(60, Timer_sec); ptTimerTable[0] = &Timer...moreI’ve created a pointer table containing pointers to a series of up timers. Here’s an example of how the table values are assigned, see below. SetUpTimerTarget(60, Timer_sec); ptTimerTable[0] = &Timer_sec; I then start the time in later code, see below. StartTimer(*ptTimerTable[0]); When Test Compiling I get the following syntax error. Unable to find variable or command “*ptTimerTable[0]” What am I doing wrong here? Thanks in Advance, DKMarion... <less Can I use Ignition Node-RED module with Ignition Edge Free Trial? Forum - Published: I’m attempting to set up an API Key with the Ignition Node-RED module, but am getting an error that the license is invalid. I can’t tell if this is saying that (a) I can’t use this module with Ignition...moreI’m attempting to set up an API Key with the Ignition Node-RED module, but am getting an error that the license is invalid. I can’t tell if this is saying that (a) I can’t use this module with Ignition Edge unless I have an Ignition Edge license (and am not just using the free trial) or (b) I can’t use this module with Ignition Edge because the module license itself is invalid. image1254×213 9.61 KB Has anyone come across this?... <less PAC 10.5 Analog Input - Moving Average Forum - Published: A simple questions that I cannot find documented (or I didn’t look in the right place). The new Moving Average built into the Analog Inputs can be setup to look at X Number of Samples. What determines...moreA simple questions that I cannot find documented (or I didn’t look in the right place). The new Moving Average built into the Analog Inputs can be setup to look at X Number of Samples. What determines the rate of each sample ? A moving average of 10 samples at 1 sec is very different from a moving average of 10 samples at 100msec - both of which I’ve done in the past via logic. Is it based on every time the configuration reads the point (which may or may not be at a set time base) OR is it based...... <less Page 1 of 128Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Pointer to an Up Timer Forum - Published: I’ve created a pointer table containing pointers to a series of up timers. Here’s an example of how the table values are assigned, see below. SetUpTimerTarget(60, Timer_sec); ptTimerTable[0] = &Timer...moreI’ve created a pointer table containing pointers to a series of up timers. Here’s an example of how the table values are assigned, see below. SetUpTimerTarget(60, Timer_sec); ptTimerTable[0] = &Timer_sec; I then start the time in later code, see below. StartTimer(*ptTimerTable[0]); When Test Compiling I get the following syntax error. Unable to find variable or command “*ptTimerTable[0]” What am I doing wrong here? Thanks in Advance, DKMarion... <less Can I use Ignition Node-RED module with Ignition Edge Free Trial? Forum - Published: I’m attempting to set up an API Key with the Ignition Node-RED module, but am getting an error that the license is invalid. I can’t tell if this is saying that (a) I can’t use this module with Ignition...moreI’m attempting to set up an API Key with the Ignition Node-RED module, but am getting an error that the license is invalid. I can’t tell if this is saying that (a) I can’t use this module with Ignition Edge unless I have an Ignition Edge license (and am not just using the free trial) or (b) I can’t use this module with Ignition Edge because the module license itself is invalid. image1254×213 9.61 KB Has anyone come across this?... <less PAC 10.5 Analog Input - Moving Average Forum - Published: A simple questions that I cannot find documented (or I didn’t look in the right place). The new Moving Average built into the Analog Inputs can be setup to look at X Number of Samples. What determines...moreA simple questions that I cannot find documented (or I didn’t look in the right place). The new Moving Average built into the Analog Inputs can be setup to look at X Number of Samples. What determines the rate of each sample ? A moving average of 10 samples at 1 sec is very different from a moving average of 10 samples at 100msec - both of which I’ve done in the past via logic. Is it based on every time the configuration reads the point (which may or may not be at a set time base) OR is it based...... <less Page 1 of 128Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Can I use Ignition Node-RED module with Ignition Edge Free Trial? Forum - Published: I’m attempting to set up an API Key with the Ignition Node-RED module, but am getting an error that the license is invalid. I can’t tell if this is saying that (a) I can’t use this module with Ignition...moreI’m attempting to set up an API Key with the Ignition Node-RED module, but am getting an error that the license is invalid. I can’t tell if this is saying that (a) I can’t use this module with Ignition Edge unless I have an Ignition Edge license (and am not just using the free trial) or (b) I can’t use this module with Ignition Edge because the module license itself is invalid. image1254×213 9.61 KB Has anyone come across this?... <less PAC 10.5 Analog Input - Moving Average Forum - Published: A simple questions that I cannot find documented (or I didn’t look in the right place). The new Moving Average built into the Analog Inputs can be setup to look at X Number of Samples. What determines...moreA simple questions that I cannot find documented (or I didn’t look in the right place). The new Moving Average built into the Analog Inputs can be setup to look at X Number of Samples. What determines the rate of each sample ? A moving average of 10 samples at 1 sec is very different from a moving average of 10 samples at 100msec - both of which I’ve done in the past via logic. Is it based on every time the configuration reads the point (which may or may not be at a set time base) OR is it based...... <less Page 1 of 128Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
PAC 10.5 Analog Input - Moving Average Forum - Published: A simple questions that I cannot find documented (or I didn’t look in the right place). The new Moving Average built into the Analog Inputs can be setup to look at X Number of Samples. What determines...moreA simple questions that I cannot find documented (or I didn’t look in the right place). The new Moving Average built into the Analog Inputs can be setup to look at X Number of Samples. What determines the rate of each sample ? A moving average of 10 samples at 1 sec is very different from a moving average of 10 samples at 100msec - both of which I’ve done in the past via logic. Is it based on every time the configuration reads the point (which may or may not be at a set time base) OR is it based...... <less Page 1 of 128Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items